CoChat

Intracranial Aneurysms: Treatment with Bare Platinum Coils—Aneurysm Packing, Complex Coils, and Angiographic Recurrence

Piotin, Michel, Spelle, Laurent, Mounayer, Charbel, Salles-Rezende, Marco T., Giansante-Abud, Daniel, Vanzin-Santos, Ricardo, Moret, Jacques · 2007 · Radiology
Cited by 170

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

PURPOSE: To retrospectively assess, with three-dimensional rotational angiography, the relationship between packing, complex coils, and angiographic recurrence of aneurysms treated with coils. MATERIALS AND METHODS: Informed consent was waived by the institutional review board that approved the study. Results at follow-up angiography of 255 aneurysms in 223 patients (161 female and 62 male patients; mean age, 48 years) were dichotomized into presence or absence of recurrence. The degree of packing of aneurysms treated with complex coils alone, with complex and helical coils, and with helical coils only was compared for significant differences. With generalized estimating equations analysis, relative risk (RR) for recurrence was calculated for mode of manifestation, duration of follow-up, aneurysm volume, packing, initial angiographic result, percentage of complex coils, aneurysm location, and multiplicity of aneurysms. RESULTS: Follow-up angiography revealed recurrence in 28.6% of aneurysms at a mean follow-up of 12 months; 5.5% were amenable to re-treatment. Aneurysms treated with complex and those treated with helical coils only had a mean packing of 27% and 26%, respectively. There was no significant difference between packing of aneurysms treated with complex and those treated with helical coils (P = .538). Recurring and stable aneurysms both had a mean packing of 27%. Generalized estimating equations analysis showed significant differences between duration of follow-up and recurrence (P = .001, RR = 3.39), between aneurysm volume and recurrence (P < .001, RR = 6.15), and between hemorrhagic manifestation and recurrence (P = .002, RR = 3.17). There was no significant difference between packing and recurrence, between initial angiographic result and recurrence, between percentage of complex coils and recurrence, between aneurysm location and recurrence, or between multiplicity of aneurysms and recurrence. CONCLUSION: More angiographic recurrences are detected over time. Complex coils do not augment aneurysm packing. Packing is not related to protection against recurrence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2431060006

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 170

Metadata

Authors
Piotin, M., Spelle, L., Mounayer, C., Salles-Rezende, M. T., Giansante-Abud, D., Vanzin-Santos, R., & Moret, J.
Venue
Radiology
Published
2007-05
Volume
243
Issue
2
Pages
500-508
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2138123546
Cited by
170
References
14
FWCI
8.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.