CoChat

Endovascular Treatment of Ruptured Intracranial Aneurysms with Detachable Coils: Long-term Clinical and Serial Angiographic Results

Sluzewski, Menno, van Rooij, Willem Jan, Rinkel, Gabriël J. E., Wijnalda, Douwe · 2003 · Radiology
Cited by 193

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the stability of aneurysm occlusion over time, the need for additional treatments, and the long-term clinical outcome of patients, with emphasis on late recurrences of bleeding. MATERIALS AND METHODS: The records of 160 patients with aneurysmal subarachnoid hemorrhage who were treated with coils were retrospectively reviewed. Follow-up angiography was performed 6 and 18 months after coil placement, and the results were classified as complete, near complete, and incomplete occlusion. RESULTS: Six (4%) of the 160 patients experienced procedural mortality or dependency. After a mean follow-up of 36 months, 134 (84%) patients had a good outcome. Outcome was independent of aneurysm size and location and timing of treatment. Reopening of the aneurysm occurred exclusively during the first 6 months after coil placement, mainly in aneurysms larger than 15 mm. Between 6 and 18 months, no change in aneurysm occlusion was observed. Additional coil placement was performed in 15 (9%) patients. After this second coil placement, nine (7%) aneurysms were still incompletely occluded. Additional therapy was performed in eight (5%) patients. Two recurrences of bleeding were observed in two incompletely occluded large aneurysms. No recurrences of bleeding occurred in patients with completely or near completely occluded aneurysms. CONCLUSION: Coil placement is an effective and safe treatment strategy for patients with aneurysmal subarachnoid hemorrhage. If aneurysm occlusion is sufficient at 6 months, the yield of further follow-up angiography is very low.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2273020656

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 193

Metadata

Authors
Sluzewski, M., van Rooij, W. J., Rinkel, G. J. E., & Wijnalda, D.
Venue
Radiology
Published
2003-06
Volume
227
Issue
3
Pages
720-724
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1994033557
Cited by
193
References
16
FWCI
7.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Endovascular Treatment of Ruptured Intracranial Aneurysms with Detachable Coils: Long-term Clinical and Serial Angiographic Results. https://app.cochat.ai/papers/10.1148/radiol.2273020656
The paper
Sluzewski, M., van Rooij, W. J., Rinkel, G. J. E., & Wijnalda, D. (2003). Endovascular Treatment of Ruptured Intracranial Aneurysms with Detachable Coils: Long-term Clinical and Serial Angiographic Results. Radiology. https://doi.org/10.1148/radiol.2273020656

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.