Imaging Techniques for Detection and Management of Endoleaks after Endovascular Aortic Aneurysm Repair1
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Endovascular aortic aneurysm repair (EVAR) is evolving into a viable alternative to open surgical repair for many patients with abdominal and thoracic aortic aneurysms. Endoleak development is a complication of EVAR and represents one of the limitations of this procedure. Endoleaks represent blood flow outside the stent-graft lumen but within the aneurysm sac. Lifelong imaging surveillance of patients after EVAR is critical to detect endoleaks for the patient's benefit and to determine the long-term performance of the stent-graft. Although computed tomographic angiography is the most commonly used examination for imaging surveillance, magnetic resonance angiography, ultrasonography, and digital subtraction angiography all have a role in endoleak detection and management. This review will focus on imaging techniques used for endoleak detection and the role imaging surveillance plays in the overall care of the post-EVAR patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transfemoral Intraluminal Graft Implantation for Abdominal Aortic Aneurysms
Parodi, J. C., Palmaz, J. C., & Barone, H. D. (1991) · Annals of Vascular Surgery · doi:10.1007/bf02015271 · Cited by 3,322
White, G. H., Yu, W., May, J., Chaufour, X., & Stephen, M. S. (1997) · Journal of Endovascular Therapy · doi:10.1177/152660289700400207 · Cited by 771
Harris, P. L., Vallabhaneni, S. R., Desgranges, P., Becquemin, J., van Marrewijk, C., & Laheij, R. J. F. (2000) · Journal of Vascular Surgery · doi:10.1067/mva.2000.109990 · Cited by 735
Veith, F. J., Baum, R. A., Ohki, T., Amor, M., Adiseshiah, M., Blankensteijn, J. D., Buth, J., Chuter, T. A. M., Fairman, R. M., Gilling-Smith, G. L., et al. (2002) · Journal of Vascular Surgery · doi:10.1067/mva.2002.123095 · Cited by 610
White, G. H., May, J., Waugh, R. C., Chaufour, X., & Yu, W. (1998) · Journal of Endovascular Therapy · doi:10.1177/152660289800500403 · Cited by 390
Zarins, C. K., White, R. A., Hodgson, K. J., Schwarten, D. E., & Fogarty, T. J. (2000) · Journal of Vascular Surgery · doi:10.1067/mva.2000.108278 · Cited by 261
Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography
Rubin, G. D., Shiau, M. C., Leung, A. N., Kee, S. T., Logan, L. J., & Sofilos, M. C. (2000) · Radiology · doi:10.1148/radiology.215.3.r00jn18670 · Cited by 248
Aneurysm rupture after endovascular repair using the AneuRx stent graft
Zarins, C. K., White, R. A., & Fogarty, T. J. (2000) · Journal of Vascular Surgery · doi:10.1067/mva.2000.106497 · Cited by 226
Jacobs, T. S., Won, J., Gravereaux, E. C., Faries, P. L., Morrissey, N. J., Teodorescu, V. J., Hollier, L. H., & Marin, M. L. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.58 · Cited by 221
McCullough, P. A., & Soman, S. S. (2005) · Critical Care Clinics · doi:10.1016/j.ccc.2004.12.003 · Cited by 180
Cited by
Multidetector CT of Thoracic Aortic Aneurysms
Agarwal, P. P., Chughtai, A., Matzinger, F. R. K., & Kazerooni, E. A. (2009) · RadioGraphics · doi:10.1148/rg.292075080 · Cited by 164
Metadata
- Authors
- Stavropoulos, S. W., & Charagundla, S. R.
- Venue
- Radiology
- Published
- 2007-06
- Volume
- 243
- Issue
- 3
- Pages
- 641-655
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2133624681
- Cited by
- 243
- References
- 35
- FWCI
- 12.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging Techniques for Detection and Management of Endoleaks after Endovascular Aortic Aneurysm Repair1. https://app.cochat.ai/papers/10.1148/radiol.2433051649
- The paper
- Stavropoulos, S. W., & Charagundla, S. R. (2007). Imaging Techniques for Detection and Management of Endoleaks after Endovascular Aortic Aneurysm Repair1. Radiology. https://doi.org/10.1148/radiol.2433051649
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.