CoChat

CT Colonography: False-Negative Interpretations

Doshi, Taral, Rusinak, David, Halvorsen, Robert A., Rockey, Don C., Suzuki, Kenji, Dachman, Abraham H. · 2007 · Radiology
Cited by 83

The DOI matches its Crossref record.

Abstract

PURPOSE: To retrospectively evaluate if false-negative interpretations at computed tomographic (CT) colonography are due to observer error. MATERIALS AND METHODS: This study was HIPAA compliant and had institutional review board approval, with waiver of informed consent. An initial unblinded review of CT colonographic image data was used to generate reconciliation reports for all false-negative polyp candidates 6.0 mm or larger. These findings were then verified by two experienced readers. After reports from the original study and reconciliation reports were reviewed, errors were classified as observer (measurement or perceptual) errors, technical errors (eg, those caused by insufficient distention, fluid), or not reconcilable. Per-polyp and per-patient sensitivity values were calculated for adenomas 6.0 mm or larger in the original data set and again by assuming elimination of technical and observer errors. RESULTS: Of the original data set of 228 available polyps, 147 were adenomas; for this subgroup, the per-patient sensitivity was 70% and 68% at 10.0- and 6.0-mm thresholds, respectively. When all histologic types were considered, 114 polyps were false-negative findings. Of these, 53% (60 of 114) were attributed to observer-related errors, and 26% were attributed to errors classified as technical. After detailed retrospective reconciliation of individual polyps (so as to exclude any potentially correctable observer error), the per-polyp sensitivity of CT colonography for adenomas 10.0 mm or larger increased to 93%, and the per-patient sensitivity increased to 91%. When observer and technical errors were accounted for, eight (5.4%) of 147 adenomas 6.0 mm or larger could not be detected. If all technical errors and observer errors were scored as true-positive findings, the sensitivity for adenomas 6.0 mm or larger would have been 95% on both a per-polyp and a per-patient basis. CONCLUSION: The major contributor to error at CT colonography was observer perceptual error, while observer measurement error played a smaller role.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2441061122

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Doshi, T., Rusinak, D., Halvorsen, R. A., Rockey, D. C., Suzuki, K., & Dachman, A. H.
Venue
Radiology
Published
2007-07
Volume
244
Issue
1
Pages
165-173
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2138797814
Cited by
83
References
0
FWCI
6.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.