R2 and R2* Mapping for Sensing Cell-bound Superparamagnetic Nanoparticles: In Vitro and Murine in Vivo Testing

Kuhlpeter, Rebecca, Dahnke, Hannes, Matuszewski, Lars, Persigehl, Thorsten, von Wallbrunn, Angelika, Allkemper, Thomas, Heindel, Walter L., Schaeffter, Tobias, Bremer, Christoph · 2007 · Radiology
Cited by 110

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively determine the cellular iron uptake by using R2 and R2* mapping with multiecho readout gradient-echo and spin-echo sequences. MATERIALS AND METHODS: All experiments were approved by the institutional animal care committee. Lung carcinoma cells were lipofected with superparamagnetic iron oxides (SPIOs). Agarose gel phantoms containing (a) 1 x 10(5) CCL-185 cells per milliliter of agarose gel with increasing SPIO load (0.01-5.00 mg of iron per milliliter in the medium), (b) different amounts (5.0 x 10(3) to 2.5 x 10(5) cells per milliliter of agarose gel) of identically loaded cells, and (c) free (non-cell-bound) SPIOs at the iron concentrations described for (b) were analyzed with 3.0-T R2 and R2* relaxometry. Iron uptake was analyzed with light microscopy, quantified with atomic emission spectroscopy (AES), and compared with MR data. For in vivo relaxometry, agarose gel pellets containing SPIO-labeled cells, free SPIO, unlabeled control cells, and pure agarose gel were injected into three nude mice each. Linear and nonlinear regression analyses were performed. RESULTS: Light microscopy and AES revealed efficient SPIO particle uptake (mean uptake: 0.22 pg of iron per cell +/- 0.1 [standard deviation] for unlabeled cells, 31.17 pg of iron per cell +/- 4.63 for cells incubated with 0.5 mg/mL iron). R2 and R2* values were linearly correlated with cellular iron load, number of iron-loaded cells, and content of freely dissolved iron (r(2) range, 0.92-0.99; P < .001). For cell-bound SPIO, R2* effects were significantly greater than R2 effects (P < .01); for free SPIO, R2 and R2* effects were similar. In vivo relaxometry enabled accurate prediction of the number of labeled cells. R2' (R2* - R2) mapping enabled differentiation between cell-bound and free iron in vitro and in vivo. CONCLUSION: Quantitative R2 and R2* mapping enables noninvasive estimations of cellular iron load and number of iron-labeled cells. Cell-bound SPIOs can be differentiated from free SPIOs with R2' imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2451061345

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 110

Metadata

Authors
Kuhlpeter, R., Dahnke, H., Matuszewski, L., Persigehl, T., von Wallbrunn, A., Allkemper, T., Heindel, W. L., Schaeffter, T., & Bremer, C.
Venue
Radiology
Published
2007-11
Volume
245
Issue
2
Pages
449-457
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2105939926
Cited by
110
References
3
FWCI
6.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.