Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 245

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Acute Pulmonary Embolism: Sensitivity and Specificity of Ventilation-Perfusion Scintigraphy in PIOPED II Study

Sostman, H. Dirk, Stein, Paul D., Gottschalk, Alexander, Matta, Fadi, Hull, Russell, Goodman, Larry·2008·Radiology

Abstract

PURPOSE: To use Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) II data to retrospectively determine sensitivity and specificity of ventilation-perfusion (V/Q) scintigraphic studies categorized as pulmonary embolism (PE) present or PE absent and the proportion of patients for whom these categories applied. MATERIALS AND METHODS: The PIOPED II study had institutional review board approval at all participating centers. Patient informed consent was obtained; the study was HIPAA compliant. Approval and consent included those for future retrospective research. Patients in the PIOPED II database of clinical and imaging results were included if they had diagnosis at computed tomographic (CT) angiography, Wells score, and diagnosis at V/Q scanning. V/Q scan central readings were recategorized as PE present (PIOPED II reading = high probability of PE), PE absent (PIOPED II reading = very low probability of PE or normal), or nondiagnostic (PIOPED II reading = low or intermediate probability of PE). A composite reference standard was used: the PIOPED II digital subtraction angiographic (DSA) result, or if there was no definitive DSA result, CT angiographic results that were concordant with the Wells score (ie, positive CT angiographic result and Wells score > 2 or negative CT angiographic result and Wells score < 6). Sensitivity and specificity of recategorized central readings were computed. RESULTS: With the exclusion of patients with intermediate or low probability, the sensitivity of a high probability (PE present) scan finding was 77.4% (95% confidence interval [CI]: 69.7%, 85.0%), while the specificity of very low probability or normal (PE absent) scan finding was 97.7% (95% CI: 96.4%, 98.9%). The percentage of patients with a PE present or PE absent scan finding was 73.5% (95% CI: 70.7%, 76.4%). CONCLUSION: In a population similar to that in PIOPED II, results of V/Q scintigraphy can be diagnostically definitive in a majority of patients; thus, it can be considered an appropriate pulmonary imaging procedure in patients for whom CT angiography may be disadvantageous.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2463070270

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 245

Metadata

Authors
Sostman, H. D., Stein, P. D., Gottschalk, A., Matta, F., Hull, R., & Goodman, L.
Venue
Radiology
Published
2008-03
Volume
246
Issue
3
Pages
941-946
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2121216962
Cited by
245
References
2
FWCI
12.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acute Pulmonary Embolism: Sensitivity and Specificity of Ventilation-Perfusion Scintigraphy in PIOPED II Study. https://app.cochat.ai/papers/10.1148/radiol.2463070270
The paper
Sostman, H. D., Stein, P. D., Gottschalk, A., Matta, F., Hull, R., & Goodman, L. (2008). Acute Pulmonary Embolism: Sensitivity and Specificity of Ventilation-Perfusion Scintigraphy in PIOPED II Study. Radiology. https://doi.org/10.1148/radiol.2463070270

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.