Glioma Grading by Using Histogram Analysis of Blood Volume Heterogeneity from MR-derived Cerebral Blood Volume Maps
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
PURPOSE: To retrospectively compare the diagnostic accuracy of an alternative method used to grade gliomas that is based on histogram analysis of normalized cerebral blood volume (CBV) values from the entire tumor volume (obtained with the histogram method) with that of the hot-spot method, with histologic analysis as the reference standard. MATERIALS AND METHODS: The medical ethics committee approved this study, and all patients provided informed consent. Fifty-three patients (24 female, 29 male; mean age, 48 years; age range, 14-76 years) with histologically confirmed gliomas were examined with dynamic contrast material-enhanced 1.5-T magnetic resonance (MR) imaging. CBV maps were created and normalized to unaffected white matter (normalized CBV maps). Four neuroradiologists independently measured the distribution of whole-tumor normalized CBVs and analyzed this distribution by classifying the values into area-normalized bins. Glioma grading was performed by assessing the normalized peak height of the histogram distributions. Logistic regression analysis and interobserver agreement were used to compare the proposed method with a hot-spot method in which only the maximum normalized CBV was used. RESULTS: For the histogram method, diagnostic accuracy was independent of the observer. Interobserver agreement was almost perfect for the histogram method (kappa = 0.923) and moderate for the hot-spot method (kappa = 0.559). For all observers, sensitivity was higher with the histogram method (90%) than with the hot-spot method (55%-76%). CONCLUSION: Glioma grading based on histogram analysis of normalized CBV heterogeneity is an alternative to the established hot-spot method, as it offers increased diagnostic accuracy and interobserver agreement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
The Efficacy of Diagnostic Imaging
Fryback, D. G., & Thornbury, J. R. (1991) · Medical Decision Making · doi:10.1177/0272989x9101100203 · Cited by 1,291
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Law, M., Yang, S., Wang, H., Babb, J. S., Johnson, G., Cha, S., Knopp, E. A., & Zagzag, D. (2003) · PubMed Central · Cited by 1,084
Cerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings.
Aronen, H. J., Gazit, I. E., Louis, D. N., Buchbinder, B. R., Pardo, F. S., Weisskoff, R. M., Harsh, G. R., Cosgrove, G. R., Halpern, E. F., & Hochberg, F. H. (1994) · Radiology · doi:10.1148/radiology.191.1.8134596 · Cited by 908
Boxerman, J. L., Schmainda, K. M., & Weisskoff, R. M. (2006) · PubMed · Cited by 686
Glial Neoplasms: Dynamic Contrast-enhanced T2*-weighted MR Imaging
Knopp, E. A., Cha, S., Johnson, G., Mazumdar, A., Golfinos, J. G., Zagzag, D., Miller, D. C., Kelly, P. J., & Kricheff, I. I. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn46791 · Cited by 596
Lev, M. H., Özsunar, Y., Henson, J. W., Rasheed, A. A., Barest, G. D., Harsh, G. R., Fitzek, M. M., Chiocca, E. A., Rabinov, J. D., Csavoy, A. N., et al. (2004) · PubMed · Cited by 474
Sugahara, T., Korogi, Y., Kochi, M., Ikushima, I., Hirai, T., Okuda, T., Shigematsu, Y., Liang, L., Ge, Y., Ushio, Y., et al. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.6.9843274 · Cited by 460
Cerebral blood flow: assessment with dynamic contrast-enhanced T2*-weighted MR imaging at 1.5 T.
Edelman, R. R., Mattle, H. P., Atkinson, D. J., Hill, T., Finn, J. P., Mayman, C., Ronthal, M., Hoogewoud, H. M., & Kleefield, J. (1990) · Radiology · doi:10.1148/radiology.176.1.2353094 · Cited by 304
Necrosis as a prognostic criterion in malignant supratentorial, astrocytic gliomas
Nelson, J. S., Tsukada, Y., Schoenfeld, D., Fulling, K., Lamarche, J., & Peress, N. (1983) · Cancer · doi:10.1002/1097-0142(19830801)52:3<550::aid-cncr2820520327>3.0.co;2-c · Cited by 276
Price, S. J., Jena, R., Burnet, N. G., Hutchinson, P. J., Dean, A. F., Peña, A., Pickard, J. D., Carpenter, T. A., & Gillard, J. H. (2006) · PubMed Central · Cited by 273
Donahue, K. M., Krouwer, H. G. J., Rand, S. D., Pathak, A. P., Marszalkowski, C. S., Censky, S. C., & Prost, R. W. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<845::aid-mrm10>3.0.co;2-j · Cited by 253
Wetzel, S. G., Cha, S., Johnson, G., Lee, P., Law, M., Kasow, D. L., Pierce, S. D., & Xue, X. (2002) · Radiology · doi:10.1148/radiol.2243011014 · Cited by 246
Claus, E. B., & Black, P. M. (2006) · Cancer · doi:10.1002/cncr.21733 · Cited by 226
Dynamic Magnetic Resonance Perfusion Imaging of Brain Tumors
Covarrubias, D. J., Rosen, B. R., & Lev, M. H. (2004) · The Oncologist · doi:10.1634/theoncologist.9-5-528 · Cited by 213
Schmainda, K. M., Rand, S. D., Joseph, A. M., Lund, R., Ward, B. D., Pathak, A. P., Ulmer, J. L., Baddrudoja, M. A., Baddrudoja, M. A., & Krouwer, H. G. J. (2004) · PubMed Central · Cited by 197
Low-grade gliomas in adults: A review
Sanai, N., Chang, S., & Berger, M. S. (2011) · Journal of Neurosurgery · doi:10.3171/2011.7.jns10238 · Cited by 149
CLINICAL APPLICATIONS OF INTRACRANIAL PERFUSION MR IMAGING
Lev, M. H., & Rosen, B. R. (1999) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(25)00561-1 · Cited by 146
Sugahara, T., Korogi, Y., Kochi, M., Ushio, Y., & Takahashi, M. (2001) · PubMed · Cited by 144
Grier, J. T., & Batchelor, T. (2006) · The Oncologist · doi:10.1634/theoncologist.11-6-681 · Cited by 123
Dynamic susceptibility contrast MRI of gliomas
Aronen, H. J., & Perkiö, J. (2002) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(02)00026-6 · Cited by 113
Itskovich, V. V., Samber, D. D., Mani, V., Aguinaldo, J. G. S., Fallon, J. T., Tang, C. Y., Fuster, V., & Fayad, Z. A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20154 · Cited by 86
Cited by
Imaging Intratumor Heterogeneity: Role in Therapy Response, Resistance, and Clinical Outcome
O'Connor, J. P. B., Rose, C. J., Waterton, J. C., Carano, R. A. D., Parker, G. J. M., & Jackson, A. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-0990 · Cited by 677
“In low-grade glioma, changes in just the top few centiles of voxel enhancement were prognostic for subsequent early transformation into HGG (P ¼ 0.011; ref.”
InfluentialKang, Y., Choi, S. H., Kim, Y.-J., Kim, K. G., Sohn, C.-H., Kim, J.-H., Yun, T. J., & Chang, K.-H. (2011) · Radiology · doi:10.1148/radiol.11110686 · Cited by 314
Hu, L. S., Eschbacher, J. M., Heiserman, J. E., Dueck, A. C., Shapiro, W. R., Liu, S., Karis, J. P., Smith, K. A., Coons, S. W., Nakaji, P., et al. (2012) · Neuro-Oncology · doi:10.1093/neuonc/nos112 · Cited by 216
“For all patients in this study (including the initial set of 9 patients), we analyzed all voxels within enhancing lesion masks as defined in the pMRI-FTB section above to calculate other rCBV metrics based on histogram analysis.(16,18,19) We calculated mean rCBV as the average of all rCBV values from the lesion mask v…”
MethodResultInfluentialJärnum, H., Steffensen, E. G., Knutsson, L., Fründ, E.-T., Simonsen, C. W., Lundbye-Christensen, S., Shankaranarayanan, A., Alsop, D. C., Jensen, F. T., & Larsson, E.-M. (2010) · Neuroradiology · doi:10.1007/s00234-009-0616-6 · Cited by 179
“Although the ROI approach is operator dependent and may be limited due to partial volume effects [45], there is one study showing that it is superior to histogram analyses in the grading of glial neoplasms [46], whereas other studies favour histogram analysis because of higher interobserver agreement, sensitivity and…”
MethodResultQuantification of Heterogeneity as a Biomarker in Tumor Imaging: A Systematic Review
Alic, L., Niessen, W. J., & Veenland, J. F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110300 · Cited by 164
Metadata
- Authors
- Emblem, K. E., Nedregaard, B., Nome, T., Due-Tonnessen, P., Hald, J. K., Scheie, D., Borota, O. C., Cvancarova, M., & Bjornerud, A.
- Venue
- Radiology
- Published
- 2008-06
- Volume
- 247
- Issue
- 3
- Pages
- 808-817
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2150441550
- Cited by
- 159
- References
- 24
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.