Cerebral Microbleeds: Accelerated 3D T2*-weighted GRE MR Imaging versus Conventional 2D T2*-weighted GRE MR Imaging for Detection
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to prospectively compare high-spatial-resolution accelerated three-dimensional (3D) T2*-weighted gradient-recalled-echo (GRE) magnetic resonance (MR) images with conventional two-dimensional (2D) T2*-weighted GRE MR images for the depiction of cerebral microbleeds. After obtaining institutional review board approval and informed consent, 200 elderly participants (age range, 69.7-96.7 years; 108 [54%] women) were imaged at 1.5 T by using both sequences. Presence, number, and location of microbleeds were recorded for both sequences, and differences were tested by using McNemar and signed rank tests. Cerebral microbleeds were detected in significantly more participants on 3D T2*-weighted GRE images (35.5%) than on 2D T2*-weighted GRE images (21.0%; P < .001). Furthermore, in persons with microbleeds visualized on both image sets, significantly more microbleeds (P < .001) were seen on 3D images than on 2D images. For both sequences, the proportion of participants with a microbleed in a lobar (cortical gray and subcortical white matter), deep, or infratentorial location was similar. In conclusion, accelerated 3D T2*-weighted GRE images depict more microbleeds than do conventional 2D T2*-weighted GRE images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Jeerakathil, T., Wolf, P. A., Beiser, A., Hald, J. K., Au, R., Kase, C. S., Massaro, J. M., & DeCarli, C. (2004) · Stroke · doi:10.1161/01.str.0000131809.35202.1b · Cited by 319
Cited by
Cerebral microbleeds: a guide to detection and interpretation
Greenberg, S. M., Vernooij, M. W., Cordonnier, C., Viswanathan, A., Al-Shahi Salman, R., Warach, S., Launer, L. J., Van Buchem, M. A., & Breteler, M. M. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70013-4 · Cited by 1,798
Self-citationThe Rotterdam Study: objectives and design update
Hofman, A., Breteler, M. M. B., van Duijn, C. M., Krestin, G. P., Pols, H. A., Stricker, B. H. C., Tiemeier, H., Uitterlinden, A. G., Vingerling, J. R., & Witteman, J. C. M. (2007) · European Journal of Epidemiology · doi:10.1007/s10654-007-9199-x · Cited by 1,395
Self-citationThe Microbleed Anatomical Rating Scale (MARS): Reliability of a tool to map brain microbleeds
Gregoire, S. M., Chaudhary, U. J., Brown, M. M., Yousry, T. A., Kallis, C., Jäger, H. R., & Werring, D. J. (2009) · Neurology · doi:10.1212/wnl.0b013e3181c34a7d · Cited by 846
Prevalence and Risk Factors of Cerebral Microbleeds: An Update of the Rotterdam Scan Study
Poels, M. M. F., Vernooij, M. W., Ikram, M. A., Hofman, A., Krestin, G. P., van der Lugt, A., & Breteler, M. M. B. (2010) · Stroke · doi:10.1161/strokeaha.110.595181 · Cited by 563
Self-citationDiagnosis of Cerebral Amyloid Angiopathy: Evolution of the Boston Criteria
Greenberg, S. M., & Charidimou, A. (2018) · Stroke · doi:10.1161/strokeaha.117.016990 · Cited by 439
Metadata
- Authors
- Vernooij, M. W., Ikram, M. A., Wielopolski, P. A., Krestin, G. P., Breteler, M. M. B., & van der Lugt, A.
- Venue
- Radiology
- Published
- 2008-07
- Volume
- 248
- Issue
- 1
- Pages
- 272-277
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2161659345
- Cited by
- 147
- References
- 2
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cerebral Microbleeds: Accelerated 3D T2*-weighted GRE MR Imaging versus Conventional 2D T2*-weighted GRE MR Imaging for Detection. https://app.cochat.ai/papers/10.1148/radiol.2481071158
- The paper
- Vernooij, M. W., Ikram, M. A., Wielopolski, P. A., Krestin, G. P., Breteler, M. M. B., & van der Lugt, A. (2008). Cerebral Microbleeds: Accelerated 3D T2*-weighted GRE MR Imaging versus Conventional 2D T2*-weighted GRE MR Imaging for Detection. Radiology. https://doi.org/10.1148/radiol.2481071158
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.