CoChat

Costs and Clinical Outcomes after Coronary Multidetector CT Angiography in Patients without Known Coronary Artery Disease: Comparison to Myocardial Perfusion SPECT

Min, James K., Kang, Ning, Shaw, Leslee J., Devereux, Richard B., Robinson, Matthew, Lin, Fay, Legorreta, Antonio P., Gilmore, Amanda · 2008 · Radiology
Cited by 87

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To assess costs and clinical outcomes in individuals without known coronary artery disease (CAD) who underwent multidetector computed tomographic (CT) angiography compared with those in matched patients who underwent myocardial perfusion single photon emission computed tomography (SPECT). MATERIALS AND METHODS: Data were captured from a deidentified, HIPAA-compliant data warehouse. We examined 1-year CAD costs (additional diagnostic coronary testing, CAD hospitalization, and coronary procedural and revascularization costs) and clinical outcomes in individuals without known CAD who underwent multidetector CT (n = 1647) compared with those in a matched cohort of patients who underwent myocardial perfusion SPECT (n = 6588). Cox proportional hazards models were employed for clinical outcome measures, including CAD hospitalization, myocardial infarction, and angina. RESULTS: Adjusted CAD costs in the multidetector CT group were 25.9% lower than in the myocardial perfusion SPECT group, by an average of $1075 (95% confidence interval [CI]: $243, $2570) per patient. Those in the multidetector CT group were more likely to undergo downstream testing with myocardial perfusion SPECT (odds ratio, 6.65; 95% CI: 5.05, 8.75; P < .001), while those in the myocardial perfusion SPECT group were more likely to undergo downstream testing with invasive angiography (odds ratio, 6.25; 95% CI: 4.35, 9.09; P < .001). The multidetector CT group was less likely to undergo coronary revascularization (hazard ratio, 0.76; 95% CI: 0.75, 0.77; P < .001) than the myocardial perfusion SPECT group. There was no significant difference between multidetector CT and myocardial perfusion SPECT groups for rates of myocardial infarction (0.4% for both) or CAD hospitalization (0.7% vs 1.1%, respectively), while rates of angina were significantly lower in the multidetector CT group (4.3% vs 6.4%, P < .001). CONCLUSION: Individuals without known CAD who underwent multidetector CT as an initial diagnostic test, compared with those who underwent myocardial perfusion SPECT, incurred lower health care costs with similar rates of myocardial infarction and CAD-related hospitalization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2483071453

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 87

Metadata

Authors
Min, J. K., Kang, N., Shaw, L. J., Devereux, R. B., Robinson, M., Lin, F., Legorreta, A. P., & Gilmore, A.
Venue
Radiology
Published
2008-10
Volume
249
Issue
1
Pages
62-70
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2078709855
Cited by
87
References
4
FWCI
9.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.