Evaluating Variability in Tumor Measurements from Same-day Repeat CT Scans of Patients with Non–Small Cell Lung Cancer
Open accessAbstract
PURPOSE: To evaluate the variability of tumor unidimensional, bidimensional, and volumetric measurements on same-day repeat computed tomographic (CT) scans in patients with non-small cell lung cancer. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board, with informed patient consent. Thirty-two patients with non-small cell lung cancer, each of whom underwent two CT scans of the chest within 15 minutes by using the same imaging protocol, were included in this study. Three radiologists independently measured the two greatest diameters of each lesion on both scans and, during another session, measured the same tumors on the first scan. In a separate analysis, computer software was applied to assist in the calculation of the two greatest diameters and the volume of each lesion on both scans. Concordance correlation coefficients (CCCs) and Bland-Altman plots were used to assess the agreements between the measurements of the two repeat scans (reproducibility) and between the two repeat readings of the same scan (repeatability). RESULTS: The reproducibility and repeatability of the three radiologists' measurements were high (all CCCs, >or=0.96). The reproducibility of the computer-aided measurements was even higher (all CCCs, 1.00). The 95% limits of agreements for the computer-aided unidimensional, bidimensional, and volumetric measurements on two repeat scans were (-7.3%, 6.2%), (-17.6%, 19.8%), and (-12.1%, 13.4%), respectively. CONCLUSION: Chest CT scans are well reproducible. Changes in unidimensional lesion size of 8% or greater exceed the measurement variability of the computer method and can be considered significant when estimating the outcome of therapy in a patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
New Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 1×
“To estimate the reproducibility and the repeatability of the tumor size measurements by using repeat CT data, the concordance correlation coefficient (CCC) was initially used to quantify repeatability and reproducibility (15).”
Reporting results of cancer treatment
Miller, A. B., Hoogstraten, B., Staquet, M., & Winkler, A. (1981) · Cancer · doi:10.1002/1097-0142(19810101)47:1<207::aid-cncr2820470134>3.0.co;2-6 · Cited by 7,793
Erasmus, J. J., Gladish, G. W., Broemeling, L., Sabloff, B. S., Truong, M. T., Herbst, R. S., & Munden, R. F. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.01.144 · Cited by 476
Measuring Response in Solid Tumors: Unidimensional Versus Bidimensional Measurement
James, K., Eisenhauer, E., Christian, M., Terenziani, M., Vena, D., Muldal, A., & Therasse, P. (1999) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/91.6.523 · Cited by 401
Reproducibility of metabolic measurements in malignant tumors using FDG PET.
Weber, W., Ziegler, S. I., Thödtmann, R., Hanauske, A.-R., & Schwaiger, M. (1999) · PubMed · Cited by 388
Galbraith, S. M., Lodge, M. A., Taylor, N. J., Rustin, G. J. S., Bentzen, S., Stirling, J. J., & Padhani, A. R. (2002) · NMR in Biomedicine · doi:10.1002/nbm.731 · Cited by 338
Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
Wormanns, D., Kohl, G., Klotz, E., Marheine, A., Beyer, F., Heindel, W., & Diederich, S. (2004) · European Radiology · doi:10.1007/s00330-003-2132-0 · Cited by 289
Minn, H., Zasadny, K. R., Quint, L. E., & Wahl, R. L. (1995) · Radiology · doi:10.1148/radiology.196.1.7784562 · Cited by 260
Reproducibility of quantitative dynamic MRI of normal human tissues
Padhani, A. R., Hayes, C., Landau, S., & Leach, M. O. (2002) · NMR in Biomedicine · doi:10.1002/nbm.732 · Cited by 188
Thiesse, P., Ollivier, L., Di Stefano-Louineau, D., Négrier, S., Savary, J., Pignard, K., Lasset, C., & Escudier, B. (1997) · Journal of Clinical Oncology · doi:10.1200/jco.1997.15.12.3507 · Cited by 168
Goodman, L. R., Gülsün, M., Washington, L., Nagy, P. G., & Piacsek, K. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1821 · Cited by 144
Lung Cancer: Computerized Quantification of Tumor Response—Initial Results
Zhao, B., Schwartz, L. H., Moskowitz, C. S., Ginsberg, M. S., Rizvi, N. A., & Kris, M. G. (2006) · Radiology · doi:10.1148/radiol.2413051887 · Cited by 114
Self-citationEvaluation of Tumor Measurements in Oncology: Use of Film-Based and Electronic Techniques
Schwartz, L. H., Ginsberg, M. S., DeCorato, D. R., Rothenberg, L. N., Einstein, S. G., Kijewski, P. K., & Panicek, D. M. (2000) · Journal of Clinical Oncology · doi:10.1200/jco.2000.18.10.2179 · Cited by 102
Self-citationTwo‐dimensional multi‐criterion segmentation of pulmonary nodules on helical CT images
Zhao, B., Yankelevitz, D. F., Reeves, A. P., & Henschke, C. I. (1999) · Medical Physics · doi:10.1118/1.598605 · Cited by 92
Self-citationAssessing intra, inter and total agreement with replicated readings
Barnhart, H. X., Song, J., & Haber, M. (2004) · Statistics in Medicine · doi:10.1002/sim.2006 · Cited by 73
Measuring tumor response and shape change on CT: esophageal cancer as a paradigm
Schwartz, L. H., Colville, J., Ginsberg, M. S., Wang, L., Mazumdar, M., Kalaigian, J., Hricak, H., Ilson, D. H., & Schwartz, G. K. (2006) · Annals of Oncology · doi:10.1093/annonc/mdl058 · Cited by 34
Self-citation
Cited by
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
“Using the RIDER test-retest data set, we tested the stability of the radiomic features between test and retest 10 .”
MethodTravis, W. D., Brambilla, E., Noguchi, M., Nicholson, A. G., Geisinger, K. R., Yatabe, Y., Beer, D. G., Powell, C. A., Riely, G. J., Van Schil, P. E., et al. (2011) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318206a221 · Cited by 4,792
Self-citationMacMahon, H., Naidich, D. P., Goo, J. M., Lee, K. S., Leung, A. N. C., Mayo, J. R., Mehta, A. C., Ohno, Y., Powell, C. A., Prokop, M., et al. (2017) · Radiology · doi:10.1148/radiol.2017161659 · Cited by 2,491
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Metadata
- Authors
- Zhao, B., James, L. P., Moskowitz, C. S., Guo, P., Ginsberg, M. S., Lefkowitz, R. A., Qin, Y., Riely, G. J., Kris, M. G., & Schwartz, L. H.
- Venue
- Radiology
- Published
- 2009-07
- Volume
- 252
- Issue
- 1
- Pages
- 263-272
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2124932867
- Cited by
- 339
- References
- 18
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.