The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Reproducibility of quantitative dynamic MRI of normal human tissues
Abstract
The aim of the study was to establish the normal range and to evaluate the reproducibility of dynamic contrast enhanced MRI (DCE‐MRI) parameter estimates in normal human pelvic tissues. Nineteen patients with prostate cancer, undergoing androgen deprivation treatment, had paired DCE‐MRI examinations of the pelvis using spoiled gradient‐echo sequences. Quantitative enhancement parameters were calculated for each examination: transfer constant (Ktrans), leakage space (ve) and maximum contrast medium accumulation (MCMA) of pelvic muscles, bone marrow and fat. Descriptive and reproducibility statistics were calculated: within‐patient standard deviation (wSD), repeatability and within‐patient coefficient of variation (wCV). The femoral head and ischiorectal fat showed large numbers of non‐enhancing pixels (81 and 88%, respectively). The ischial bone marrow had the highest values of kinetic parameter estimates (Ktrans 0.554 min−1, ve 18.5% and MCMA 0.164 mmol/kg). Muscle parameters values were lower (Ktrans 0.126–0.137 min−1, ve 10.6–11.5% and MCMA 0.077–0.086 mmol/kg). The mean difference between paired examinations was not significantly different from zero for any parameter. ve and MCMA had the lowest wCV (between 19 and 29%). For individuals, a log 10 Ktrans change of approximately 0.90 in muscles and 0.52 in the ischium would be statistically significant. The corresponding absolute changes for ve are 6.7% in muscle and 13.6% in the ischium. For a group of 19 patients, small changes are statistically significant (muscle log 10 Ktrans 0.208 and ve 1.5% and ischium log 10 Ktrans 0.123 and ve 3.1%). Fat and the femoral head are unreliable tissues from which to obtain kinetic parameter estimates due to poor enhancement. ve and MCMA have smaller coefficient of variation than Ktrans in muscles and ischium. Reproducibility studies of normal and pathological tissues should be incorporated into clinical research protocols that measure treatment effects by DCE‐MRI techniques. Copyright © 2002 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Jain, R. K., Safabakhsh, N., Sckell, A., Chen, Y., Jiang, P., Benjamin, L., Yuan, F., & Keshet, E. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.18.10820 · Cited by 374
Cited by
Tatum, J. L. (2006) · International Journal of Radiation Biology · doi:10.1080/09553000601002324 · Cited by 620
MRI of the tumor microenvironment
Gillies, R. J., Raghunand, N., Karczmar, G. S., & Bhujwalla, Z. M. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10181 · Cited by 550
Dynamic contrast‐enhanced MRI in clinical oncology: Current status and future directions
Padhani, A. R. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10176 · Cited by 472
Self-citationFunctional tumor imaging with dynamic contrast‐enhanced magnetic resonance imaging
Choyke, P. L., Dwyer, A. J., & Knopp, M. V. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10304 · Cited by 439
Yankeelov, T., & Gore, J. (2007) · Current Medical Imaging Reviews · doi:10.2174/157340507780619179 · Cited by 398
Metadata
- Authors
- Padhani, A. R., Hayes, C., Landau, S., & Leach, M. O.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2002-02-20
- Volume
- 15
- Issue
- 2
- Pages
- 143-153
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W1988194103
- Cited by
- 188
- References
- 2
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of quantitative dynamic MRI of normal human tissues. https://app.cochat.ai/papers/10.1002/nbm.732
- The paper
- Padhani, A. R., Hayes, C., Landau, S., & Leach, M. O. (2002). Reproducibility of quantitative dynamic MRI of normal human tissues. NMR in Biomedicine. https://doi.org/10.1002/nbm.732
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.