Abstract

Triple-rule-out (TRO) computed tomographic (CT) angiography can provide a cost-effective evaluation of the coronary arteries, aorta, pulmonary arteries, and adjacent intrathoracic structures for the patient with acute chest pain. TRO CT is most appropriate for the patient who is judged to be at low to intermediate risk for acute coronary syndrome (ACS) and whose symptoms may also be attributed to acute pathologic conditions of the aorta or pulmonary arteries. Although a regular cardiac rhythm remains an important factor in coronary CT image quality, newer CT scanners with 64 or more detector rows afford rapid electrocardiographically (ECG) gated imaging to provide high-quality TRO CT studies in patients with a heart rate of up to 80 beats per minute. Injection of iodinated contrast material (< or = 100 mL) is tailored to provide simultaneous high levels of arterial enhancement in the coronary arteries and aorta (> 300 HU) and in the pulmonary arteries (> 200 HU). To limit radiation exposure, the TRO CT examination does not include the entire chest but is constrained to incorporate the aortic arch down through the heart. Scanning parameters, including prospective ECG tube current modulation and prospective ECG gating with the "step-and-shoot" technique, are tailored to reduce radiation exposure (optimally, 5-9 mSv). When performed with appropriate attention to timing and technique, TRO CT provides coronary image quality equal to that of dedicated coronary CT angiography and pulmonary arterial images that are free of motion artifact related to cardiac pulsation. In an appropriately selected emergency department patient population, TRO CT can safely eliminate the need for further diagnostic testing in over 75% of patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2522082335

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 197

Metadata

Authors
Halpern, E. J.
Venue
Radiology
Published
2009-08
Volume
252
Issue
2
Pages
332-345
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2125854325
Cited by
197
References
34
FWCI
13.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Triple-Rule-Out CT Angiography for Evaluation of Acute Chest Pain and Possible Acute Coronary Syndrome. https://app.cochat.ai/papers/10.1148/radiol.2522082335
The paper
Halpern, E. J. (2009). Triple-Rule-Out CT Angiography for Evaluation of Acute Chest Pain and Possible Acute Coronary Syndrome. Radiology. https://doi.org/10.1148/radiol.2522082335

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.