Differences in CT Perfusion Maps Generated by Different Commercial Software: Quantitative Analysis by Using Identical Source Data of Acute Stroke Patients
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
PURPOSE: To examine the variability in the qualitative and quantitative results of computed tomographic (CT) perfusion imaging generated from identical source data of stroke patients by using commercially available software programs provided by various CT manufacturers. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. CT perfusion imaging data of 10 stroke patients were postprocessed by using five commercial software packages, each of which had a different algorithm: singular-value decomposition (SVD), maximum slope (MS), inverse filter (IF), box modulation transfer function (bMTF), and by using custom-made original software with standard (sSVD) and block-circulant (bSVD) SVD methods. Areas showing abnormalities in cerebral blood flow (CBF), mean transit time (MTT), and cerebral blood volume (CBV) were compared with each other and with the final infarct areas. Differences among the ratios of quantitative values in the final infarct areas and those in the unaffected side were also examined. RESULTS: The areas with CBF or MTT abnormalities and the ratios of these values significantly varied among software, while those of CBV were stable. The areas with CBF or MTT abnormalities analyzed by using SVD or bMTF corresponded to those obtained with delay-sensitive sSVD, but overestimated the final infarct area. The values obtained from software by using MS or IF corresponded well with those obtained from the delay-insensitive bSVD and the final infarct area. Given the similarities between CBF and MTT, all software were separated in two groups (ie, sSVD and bSVD). The ratios of CBF or MTTs correlated well within both groups, but not across them. CONCLUSION: CT perfusion imaging maps were significantly different among commercial software even when using identical source data, presumably because of differences in tracer-delay sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Wu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
Calamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Acute Stroke Imaging Research Roadmap
Wintermark, M., Albers, G. W., Alexandrov, A. V., Alger, J. R., Bammer, R., Baron, J.-C., Davis, S., Demaerschalk, B. M., Derdeyn, C. P., Donnan, G. A., et al. (2008) · Stroke · doi:10.1161/strokeaha.107.512319 · Cited by 423
Lev, M. H., Segal, A. Z., Farkas, J., Hossain, S. T., Putman, C., Hunter, G. J., Budzik, R., Harris, G. J., Buonanno, F. S., Ezzeddine, M. A., et al. (2001) · Stroke · doi:10.1161/hs0901.095680 · Cited by 316
Dynamic CT perfusion imaging of acute stroke.
Mayer, T. E., Hamann, G. F., Baranczyk, J., Rosengarten, B., Klotz, E., Wiesmann, M., Missler, U., Schulte‐Altedorneburg, G., & Brueckmann, H. J. (2000) · PubMed · Cited by 287
Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow.
Wintermark, M., Maeder, P. P., Verdun, F. R., Thiran, J., Valley, J., Schnyder, P. A., & Meuli, R. A. (2000) · PubMed · Cited by 269
Klotz, E., & König, M. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00009-1 · Cited by 234
Wintermark, M., Smith, W. S., Ko, N., Quist, M. J., Schnyder, P. A., & Dillon, W. P. (2004) · PubMed · Cited by 213
Murphy, B. D., Fox, A. J., Lee, D. H., Sahlas, D. J., Black, S. E., Hogan, M. J., Coutts, S. B., Demchuk, A. M., Goyal, M., Aviv, R. I., et al. (2008) · Radiology · doi:10.1148/radiol.2473070551 · Cited by 95
Cited by
Multiphase CT Angiography: A New Tool for the Imaging Triage of Patients with Acute Ischemic Stroke
Menon, B. K., d’Esterre, C. D., Qazi, E. M., Almekhlafi, M., Hahn, L., Demchuk, A. M., & Goyal, M. (2015) · Radiology · doi:10.1148/radiol.15142256 · Cited by 699
Cerebral Blood Flow Is the Optimal CT Perfusion Parameter for Assessing Infarct Core
Campbell, B. C. V., Christensen, S., Levi, C. R., Desmond, P. M., Donnan, G. A., Davis, S. M., & Parsons, M. W. (2011) · Stroke · doi:10.1161/strokeaha.111.618355 · Cited by 427
Campbell, B. C. V., Majoie, C. B. L. M., Albers, G. W., Menon, B. K., Yassi, N., Sharma, G., van Zwam, W. H., van Oostenbrugge, R. J., Demchuk, A. M., Guillemin, F., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30314-4 · Cited by 395
Review of Perfusion Imaging in Acute Ischemic Stroke: From Time to Tissue
Demeestere, J., Wouters, A., Christensen, S., Lemmens, R., & Lansberg, M. G. (2020) · Stroke · doi:10.1161/strokeaha.119.028337 · Cited by 302
Ma, J., Huang, J., Feng, Q., Zhang, H., Lu, H., Liang, Z., & Chen, W. (2011) · Medical Physics · doi:10.1118/1.3638125 · Cited by 249
Computed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Dani, K. A., Thomas, R. G. R., Chappell, F. M., Shuler, K., MacLeod, M. J., Muir, K. W., Wardlaw, J. M., & on behalf of the Translational Medicine Research Collaboration Multicentre Acute Stroke Imaging Study (2011) · Annals of Neurology · doi:10.1002/ana.22500 · Cited by 177
“Even analyzing the same dataset with different manufacturers’ software that purports to do the same thing can result in different perfusion deficits even for the same perfusion parameter.(79) Variation in image acquisition parameters probably also affects perfusion values.”
BackgroundKo, S.-B., Park, H.-K., Kim, B. M., Heo, J. H., Rha, J.-H., Kwon, S. U., Kim, J. S., Lee, B.-C., Suh, S. H., Jung, C., et al. (2019) · Journal of Stroke · doi:10.5853/jos.2019.00024 · Cited by 63
Metadata
- Authors
- Kudo, K., Sasaki, M., Yamada, K., Momoshima, S., Utsunomiya, H., Shirato, H., & Ogasawara, K.
- Venue
- Radiology
- Published
- 2010-01
- Volume
- 254
- Issue
- 1
- Pages
- 200-209
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2001414884
- Cited by
- 332
- References
- 13
- FWCI
- 13.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.