Magnetic resonance angiography.
The DOI matches its Crossref record.
Abstract
Pulse sequences that permit selective detection of moving spins in a magnetic resonance image have been developed. Experiments were performed by the authors to produce projected angiographic data without the use of contrast agents, with the intensity of each image pixel determined by the macroscopic velocity of the detected spins. With this method, suppression of nonmoving spins is essentially complete, yielding a high dynamic range in signal intensity for detected vessels. Selective detection of moving spins is not dependent on pulsatile flow. Consequently, not only arterial structures, but also venous structures can easily be visualized. High-resolution angiographic images can be obtained by combining the flow experiment with surface coil techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Three‐dimensional phase contrast angiography
Dumoulin, C. L., Souza, S. P., Walker, M. F., & Wagle, W. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090117 · Cited by 432
Self-citationMR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask
Bitar, R., Leung, G., Perng, R., Tadros, S., Moody, A. R., Sarrazin, J., McGregor, C., Christakis, M., Symons, S., Nelson, A., et al. (2006) · RadioGraphics · doi:10.1148/rg.262055063 · Cited by 383
MRI Estimation of Global Brain Oxygen Consumption Rate
Jain, V., Langham, M. C., & Wehrli, F. W. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.49 · Cited by 275
Caprihan, A., & Fukushima, E. (1990) · Physics Reports · doi:10.1016/0370-1573(90)90046-5 · Cited by 234
Cohen, M. S., & Weisskoff, R. M. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90094-3 · Cited by 234
Carpenter, J. P., Holland, G. A., Baum, R. A., Owen, R. S., Carpenter, J. T., & Cope, C. (1993) · Journal of Vascular Surgery · doi:10.1016/0741-5214(93)90325-g · Cited by 226
Functional Magnetic Resonance Imaging in Medicine and Physiology
Moonen, C. T. W., van Zijl, P. C. M., Frank, J. A., Le Bihan, D., & Becker, E. D. (1990) · Science · doi:10.1126/science.2218514 · Cited by 185
13C imaging—a new diagnostic platform
Månsson, S., Johansson, E., Magnusson, P., Chai, C.-M., Hansson, G., Petersson, J. S., Ståhlberg, F., & Golman, K. (2006) · European Radiology · doi:10.1007/s00330-005-2806-x · Cited by 181
Clinical applications of susceptibility weighted MR imaging of the brain – a pictorial review
Thomas, B., Somasundaram, S., Thamburaj, K., Kesavadas, C., Gupta, A. K., Bodhey, N. K., & Kapilamoorthy, T. R. (2008) · Neuroradiology · doi:10.1007/s00234-007-0316-z · Cited by 180
Wang, Y., Johnston, D. L., Breen, J. F., Iii, J. H., Jack, C. R., Julsrud, P. R., Kiely, M. J., King, B. F., Riederer, S. L., & Ehman, R. L. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360408 · Cited by 162
Metadata
- Authors
- Dumoulin, C. L., & Hart, H. R.
- Venue
- Radiology
- Published
- 1986-12
- Volume
- 161
- Issue
- 3
- Pages
- 717-720
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2064499319
- Cited by
- 506
- References
- 0
- FWCI
- 13.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.