Pheochromocytoma and paraganglioma: comparison of MR imaging with CT and I-131 MIBG scintigraphy.
The DOI matches its Crossref record.
Abstract
To ascertain the magnetic resonance (MR) imaging characteristics of pheochromocytomas and paragangliomas and to compare MR with computed tomography (CT) and iodine-131 metaiodobenzylguanidine (I-131 MIBG), 19 patients (18 with pheochromocytomas, one with a paraganglioma) were studied. The 18 patients with pheochromocytomas had had positive findings with I-131 MIBG scintigraphy. Abdominal pheochromocytomas were generally hypointense compared with normal liver on T1-weighted MR images and extremely hyperintense on T2-weighted MR images. MR imaging was preferable to CT in the evaluation of primary pheochromocytomas due to superior tissue characterization, particularly in the patient with hypertension and borderline catecholamine levels. For patients with recurrent or metastatic disease, the data suggest that I-131 MIBG scintigraphy is the examination of choice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pheochromocytoma and paraganglioma: an endocrine society clinical practice guideline
Lenders, J. W. M., Duh, Q.-Y., Eisenhofer, G., Gimenez-Roqueplo, A.-P., Grebe, S. K. G., Murad, M. H., Naruse, M., Pacak, K., & Young, W. F. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-1498 · Cited by 2,827
Recent advances in genetics, diagnosis, localization, and treatment of pheochromocytoma
Pacak, K., Linehan, W. M., Eisenhofer, G., Walther, M. M., & Goldstein, D. S. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-4-200102200-00016 · Cited by 618
Zeiger, M. A., Thompson, G. B., Duh, Q.-Y., Hamrahian, A. H., Angelos, P., Elaraj, D., Fishman, E., Kharlip, J., Zeiger, M. A., Thompson, G. B., et al. (2009) · Endocrine Practice · doi:10.4158/ep.15.s1.1 · Cited by 499
“The sensitivity of CT scanning with use of a contrast agent for the diagnosis of pheochromocytoma is 85% to 95%, with a specificity of 70% to 100%; the sensitivity of MRI exceeds 95%, with a specificity of 100% (49 [EL 3],”
Pheochromocytomas, Multiple Endocrine Neoplasia Type 2, and von Hippel-Lindau Disease
Neumann, H., Berger, D. P., Sigmund, G., Blum, U., Schmidt, D., Parmer, R. J., Volk, B., & Kirste, G. (1993) · New England Journal of Medicine · doi:10.1056/nejm199311183292103 · Cited by 465
Extra-Adrenal Pheochromocytoma
Whalen, R. K., Althausen, A. F., & Daniels, G. H. (1992) · Journal of Urology · doi:10.1016/s0022-5347(17)37119-7 · Cited by 452
Current Approaches and Recommended Algorithm for the Diagnostic Localization of Pheochromocytoma
Ilias, I., & Pacak, K. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031091 · Cited by 332
Pheochromocytomas: Detection with18F DOPA Whole-Body PET—Initial Results
Hoegerle, S., Nitzsche, E., Altehoefer, C., Ghanem, N., Manz, T., Brink, I., Reincke, M., Moser, E., & Neumann, H. P. H. (2002) · Radiology · doi:10.1148/radiol.2222010622 · Cited by 325
Pheochromocytomas: Imaging with 2-[Fluorine-18]fluoro-2-deoxy-d-glucose PET
Shulkin, B. L., Thompson, N. W., Shapiro, B., Francis, I. R., & Sisson, J. C. (1999) · Radiology · doi:10.1148/radiology.212.1.r99jl3035 · Cited by 305
Self-citationIlias, I., Yu, J., Carrasquillo, J. A., Chen, C. C., Eisenhofer, G., Whatley, M., McElroy, B., & Pacak, K. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030235 · Cited by 241
Pacak, K., Eisenhofer, G., Carrasquillo, J. A., Chen, C. C., Li, S.-T., & Goldstein, D. S. (2001) · Hypertension · doi:10.1161/01.hyp.38.1.6 · Cited by 216
Lockhart, M. E., Smith, J. K., & Kenney, P. J. (2002) · European Journal of Radiology · doi:10.1016/s0720-048x(01)00444-2 · Cited by 211
Metyrosine and Pheochromocytoma
Steinsapir, J. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.157.8.901 · Cited by 176
Recent Developments in the Diagnosis and Treatment of Pheochromocytoma
SHEPS, S. G., JIANG, N.-S., KLEE, G. G., & van HEERDEN, J. A. (1990) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)62113-2 · Cited by 173
Metadata
- Authors
- Quint, L. E., Glazer, G. M., Francis, I. R., Shapiro, B., & Chenevert, T. L.
- Venue
- Radiology
- Published
- 1987-10
- Volume
- 165
- Issue
- 1
- Pages
- 89-93
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2044485671
- Cited by
- 192
- References
- 0
- FWCI
- 11.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.