Assessment of radiologic tests: control of bias and other design considerations.
Abstract
The assessment of new radiologic tests can be seriously hampered by the presence of systematic bias. Biases can arise from incomplete verification of the sample population; omission of uninterpretable tests; absence of a definitive reference test; extraneous factors affecting interpretation; and extrapolation factors including variations in test efficacy among patients, hospitals, and the radiologists who interpret the tests. The authors review these biases that affect the results of efficacy studies and provide guidelines to avoid these problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
Zweig, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,569
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Moons, K. G. M., Wolff, R. F., Riley, R. D., Whiting, P. F., Westwood, M., Collins, G. S., Reitsma, J. B., Kleijnen, J., & Mallett, S. (2019) · Annals of Internal Medicine · doi:10.7326/m18-1377 · Cited by 1,669
Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria
Goldberg, S. N., Grassi, C. J., Cardella, J. F., Charboneau, J. W., Dodd, G. D., Dupuy, D. E., Gervais, D., Gillams, A. R., Kane, R. A., Lee, F. T., et al. (2005) · Radiology · doi:10.1148/radiol.2353042205 · Cited by 1,193
Image-Guided Tumor Ablation: Standardization of Terminology and Reporting Criteria—A 10-Year Update
Ahmed, M., Solbiati, L., Brace, C. L., Breen, D. J., Callstrom, M. R., Charboneau, J. W., Chen, M.-H., Choi, B. I., de Baère, T., Dodd, G. D., et al. (2014) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2014.08.027 · Cited by 583
Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria
Goldberg, S. N., Grassi, C. J., Cardella, J. F., Charboneau, J. W., Dodd, G. D., Dupuy, D. E., Gervais, D. A., Gillams, A. R., Kane, R. A., Lee, F. T., et al. (2009) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2009.04.011 · Cited by 519
Dinnes, J., Deeks, J., Kirby, J., & Roderick, P. (2005) · Health Technology Assessment · doi:10.3310/hta9120 · Cited by 438
Does This Patient Have Acute Cholecystitis?
Trowbridge, R. L., Rutkowski, N. K., & Shojania, K. G. (2003) · JAMA · doi:10.1001/jama.289.1.80 · Cited by 388
The interpretation of diagnostic tests
Shapiro, D. E. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800203 · Cited by 383
Development and validation of methods for assessing the quality of diagnostic accuracy studies
Whiting, P., Rutjes, A., Dinnes, J., Reitsma, J., Bossuyt, P., & Kleijnen, J. (2004) · Health Technology Assessment · doi:10.3310/hta8250 · Cited by 372
Sica, G. T. (2006) · Radiology · doi:10.1148/radiol.2383041109 · Cited by 331
Staging non—small cell lung cancer by whole-body positron emission tomographic imaging
Valk, P. E., Pounds, T. R., Hopkins, D. M., Haseman, M. K., Hofer, G. A., Greiss, H. B., Myers, R. W., & Lutrin, C. L. (1995) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00752-0 · Cited by 316
McDowell, I., Kristjansson, B., Hill, G. B., & Hébert, R. (1997) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(97)00060-7 · Cited by 307
Whole-Body PET Imaging With [18F]Fluorodeoxyglucose in Management of Recurrent Colorectal Cancer
Valk, P. E. (1999) · Archives of Surgery · doi:10.1001/archsurg.134.5.503 · Cited by 291
Diagnostic precision of nanoparticle-enhanced MRI for lymph-node metastases: a meta-analysis
Will, O., Purkayastha, S., Chan, C., Athanasiou, T., Darzi, A. W., Gedroyc, W., & Tekkis, P. P. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(05)70537-4 · Cited by 260
Transcatheter Therapy for Hepatic Malignancy: Standardization of Terminology and Reporting Criteria
Brown, D. B., Gould, J. E., Gervais, D. A., Goldberg, S. N., Murthy, R., Millward, S. F., Rilling, W. S., Geschwind, J.-F. S., Salem, R., Vedantham, S., et al. (2009) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2009.04.021 · Cited by 257
Koçak, B., Ponsiglione, A., Stanzione, A., Bluethgen, C., Santinha, J., Ugga, L., Huisman, M., Klontzas, M. E., Cannella, R., & Cuocolo, R. (2024) · Diagnostic and Interventional Radiology · doi:10.4274/dir.2024.242854 · Cited by 168
Metadata
- Authors
- Begg, C. B., & McNeil, B. J.
- Venue
- Radiology
- Published
- 1988-05
- Volume
- 167
- Issue
- 2
- Pages
- 565-569
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1972886619
- Cited by
- 213
- References
- 0
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.