The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia.
Abstract
Efficacy and safety considerations for hyperthermia (HT) cancer therapy require accurate temperature measurements throughout the heated volume. Noninvasive thermometry methods have been proposed, including magnetic resonance (MR) imaging based on the temperature dependence of the relaxation time T1. However, the temperature accuracy achieved to date with T1 measurements does not fulfill the HT requirements (1 degree C/cm). The authors propose to use molecular diffusion, for which temperature dependence is well known. Molecular diffusion is more sensitive than T1 and can be determined with high accuracy with MR imaging. Diffusion and derived temperature images were obtained with a 2 X 2-mm pixel size in a polyacrylamide gel phantom heated inside the head coil of a clinical 0.5-T whole-body MR imaging system by means of a modified clinical HT device made compatible with the system. Temperatures determined from these images with 0.8-cm2 regions of interest were found to be within 0.5 degrees C of those recorded with thermocouples placed inside the gel. The utility of this method in clinical hyperthermia is enhanced by its potential to also help monitor blood perfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Diffusion-weighted MR Imaging of the Brain
Schaefer, P. W., Grant, P. E., & Gonzalez, R. G. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv24331 · Cited by 1,052
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Metadata
- Authors
- Le Bihan, D., Delannoy, J., & Levin, R. L.
- Venue
- Radiology
- Published
- 1989-06
- Volume
- 171
- Issue
- 3
- Pages
- 853-857
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2089026118
- Cited by
- 493
- References
- 1
- FWCI
- 15.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia. https://app.cochat.ai/papers/10.1148/radiology.171.3.2717764
- The paper
- Le Bihan, D., Delannoy, J., & Levin, R. L. (1989). Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia. Radiology. https://doi.org/10.1148/radiology.171.3.2717764
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.