Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia.
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Efficacy and safety considerations for hyperthermia (HT) cancer therapy require accurate temperature measurements throughout the heated volume. Noninvasive thermometry methods have been proposed, including magnetic resonance (MR) imaging based on the temperature dependence of the relaxation time T1. However, the temperature accuracy achieved to date with T1 measurements does not fulfill the HT requirements (1 degree C/cm). The authors propose to use molecular diffusion, for which temperature dependence is well known. Molecular diffusion is more sensitive than T1 and can be determined with high accuracy with MR imaging. Diffusion and derived temperature images were obtained with a 2 X 2-mm pixel size in a polyacrylamide gel phantom heated inside the head coil of a clinical 0.5-T whole-body MR imaging system by means of a modified clinical HT device made compatible with the system. Temperatures determined from these images with 0.8-cm2 regions of interest were found to be within 0.5 degrees C of those recorded with thermocouples placed inside the gel. The utility of this method in clinical hyperthermia is enhanced by its potential to also help monitor blood perfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Self-citationBottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
Stejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894
Diffusion and Nuclear Spin Relaxation in Water
Simpson, J. H., & Carr, H. Y. (1958) · Physical Review · doi:10.1103/physrev.111.1201 · Cited by 444
The spatial mapping of translational diffusion coefficients by the NMR imaging technique
Taylor, D. G., & Bushell, M. C. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/009 · Cited by 344
MR imaging of laser-tissue interactions.
Jolesz, F. A., Bleier, A. R., Jakab, P. D., Ruenzel, P., Hüttl, K., & Jako, G. J. (1988) · Radiology · doi:10.1148/radiology.168.1.3380968 · Cited by 344
Imagerie de diffusion in-vivo par résonance magnétique nucléaire
Bihan, D. L., & Breton, E. (1985) · HAL · Cited by 238
Cited by
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Rieke, V., & Butts Pauly, K. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21265 · Cited by 1,108
Diffusion-weighted MR Imaging of the Brain
Schaefer, P. W., Grant, P. E., & Gonzalez, R. G. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv24331 · Cited by 1,052
A precise and fast temperature mapping using water proton chemical shift
Ishihara, Y., Calderon, A., Watanabe, H., Okamoto, K., Suzuki, Y., Kuroda, K., & Suzuki, Y. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340606 · Cited by 1,027
Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imaging
Warach, S., Gaa, J., Siewert, B., Wielopolski, P., & Edelman, R. R. (1995) · Annals of Neurology · doi:10.1002/ana.410370214 · Cited by 1,004
(2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Echo-planar imaging of intravoxel incoherent motion.
Turner, R., Le Bihan, D., Maier, J., Vavrek, R., Hedges, L. K., & Pekar, J. (1990) · Radiology · doi:10.1148/radiology.177.2.2217777 · Cited by 581
Self-citationMagnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Gavilán, H., Avugadda, S. K., Fernández-Cabada, T., Soni, N., Cassani, M., Mai, B. T., Chantrell, R., & Pellegrino, T. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00427a · Cited by 525
Benveniste, H., Hedlund, L. W., & Johnson, G. A. (1992) · Stroke · doi:10.1161/01.str.23.5.746 · Cited by 508
Mintorovitch, J., Moseley, M. E., Chileuitt, L., Shimizu, H., Cohen, Y., & Weinstein, P. R. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180106 · Cited by 507
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Self-citationShukla‐Dave, A., Obuchowski, N. A., Chenevert, T. L., Jambawalikar, S., Schwartz, L. H., Malyarenko, D., Huang, W., Noworolski, S. M., Young, R. J., Shiroishi, M. S., et al. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26518 · Cited by 389
Ex vivo tissue‐type independence in proton‐resonance frequency shift MR thermometry
Peters, R. T. D., Hinks, R. S., & Henkelman, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400316 · Cited by 320
Busza, A. L., Allen, K. L., King, M. D., van Bruggen, N., Williams, S. R., & Gadian, D. G. (1992) · Stroke · doi:10.1161/01.str.23.11.1602 · Cited by 311
Le Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010103 · Cited by 288
Self-citationIn vivo diffusion‐weighted MRI of the breast: Potential for lesion characterization
Sinha, S., Lucas‐Quesada, F. A., Sinha, U., DeBruhl, N., & Bassett, L. W. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10116 · Cited by 268
Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo
Tofts, P. S., Lloyd, D., Clark, C. A., Barker, G. J., Parker, G. J. M., McConville, P., Baldock, C., & Pope, J. M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<368::aid-mrm8>3.0.co;2-b · Cited by 265
MR temperature mapping of focused ultrasound surgery
Cline, H. E., Hynynen, K., Hardy, C. J., Watkins, R. D., Schenck, J. F., & Jolesz, F. A. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310608 · Cited by 260
Cohen, M. S., & Weisskoff, R. M. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90094-3 · Cited by 234
Magnetic resonance thermometry: Methodology, pitfalls and practical solutions
Winter, L., Oberacker, E., Paul, K., Ji, Y., Oezerdem, C., Ghadjar, P., Thieme, A., Budach, V., Wust, P., & Niendorf, T. (2016) · International Journal of Hyperthermia · doi:10.3109/02656736.2015.1108462 · Cited by 221
“MR thermometry [17,18], the first decade of development”
Dyrby, T. B., Baaré, W. F. C., Alexander, D. C., Jelsing, J., Garde, E., & Søgaard, L. V. (2011) · Human Brain Mapping · doi:10.1002/hbm.21043 · Cited by 216
“Molecular motion is highly sensitive to changes in the environmental temperature and such changes should therefore be avoided while acquiring DWI datasets [Le Bihan et al., 1989]: for example, an increase in tissue temperature increases diffusivity and consequently the MR signal decreases.”
BackgroundMR thermometry‐based feedback control of laser interstitial thermal therapy at 980 nm
McNichols, R. J., Gowda, A., Kangasniemi, M., Bankson, J. A., Price, R. E., & Hazle, J. D. (2004) · Lasers in Surgery and Medicine · doi:10.1002/lsm.10243 · Cited by 215
Diffusion MRI: Precision, accuracy and flow effects
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080706 · Cited by 211
Magnetic nanoparticle temperature estimation
Weaver, J. B., Rauwerdink, A. M., & Hansen, E. W. (2009) · Medical Physics · doi:10.1118/1.3106342 · Cited by 209
Impact of therapeutic hypothermia on MRI diffusion changes in neonatal encephalopathy
Bednarek, N., Mathur, A., Inder, T., Wilkinson, J., Neil, J., & Shimony, J. (2012) · Neurology · doi:10.1212/wnl.0b013e318253d589 · Cited by 201
Chung, A. H., Hynynen, K., Colucci, V., Oshio, K., Cline, H. E., & Jolesz, F. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360513 · Cited by 198
Transient decrease in water diffusion observed in human occipital cortex during visual stimulation
Darquié, A., Poline, J.-B., Poupon, C., Saint-Jalmes, H., & Le Bihan, D. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.151125698 · Cited by 194
MR Imaging–Controlled Focused Ultrasound Ablation: A Noninvasive Image-Guided Surgery
Jolesz, F. A., Hynynen, K., McDannold, N., & Tempany, C. (2005) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2005.04.008 · Cited by 193
Functional Magnetic Resonance Imaging in Medicine and Physiology
Moonen, C. T. W., van Zijl, P. C. M., Frank, J. A., Le Bihan, D., & Becker, E. D. (1990) · Science · doi:10.1126/science.2218514 · Cited by 185
Self-citationOdéen, H., & Parker, D. L. (2019) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2019.01.003 · Cited by 182
“where Ea is the activation energy for translational molecular diffusion, k is the Boltzmann constant, and T is the absolute tissue temperature [187,188].”
BackgroundNeeman, M., Freyer, J. P., & Sillerud, L. O. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210117 · Cited by 179
Magnetic resonance temperature imaging
Denis de Senneville, B., Quesson, B., & Moonen, C. T. W. (2005) · International Journal of Hyperthermia · doi:10.1080/02656730500133785 · Cited by 175
“Since then, alternative MR temperature imaging methods have been proposed, based on diffusion coefficient (D) [2], proton resonance frequency (PRF) [3] of tissue water and other temperature-dependent parameters.”
BackgroundMRI Thermometry Based on PARACEST Agents
Zhang, S., Malloy, C. R., & Sherry, A. D. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053799t · Cited by 173
MRI characterization of diffusion coefficients in a rat spinal cord injury model
Ford, J. C., Hackney, D. B., Alsop, D. C., Jara, H., Joseph, P. M., Hand, C. M., & Black, P. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310504 · Cited by 171
Bulakbasi, N., Guvenc, I., Onguru, O., Erdogan, E., Tayfun, C., & Ucoz, T. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200411000-00003 · Cited by 159
“By using different b values, a quantitative map of the apparent diffusion coefficients (ADC) can be calculated, which allows the measurement of the apparent diffusion of water protons (in mm(2)/sn).(14,15) It has been shown that DWI can detect the limited molecular movement of water in acute ischemia caused by cytotox…”
Metadata
- Authors
- Le Bihan, D., Delannoy, J., & Levin, R. L.
- Venue
- Radiology
- Published
- 1989-06
- Volume
- 171
- Issue
- 3
- Pages
- 853-857
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2089026118
- Cited by
- 493
- References
- 15
- FWCI
- 15.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.