Aortoenteric fistula and perigraft infection: evaluation with CT.
Abstract
A blinded retrospective study was performed to determine the sensitivity and specificity of computed tomography (CT) in detecting perigraft infection (PGI) and aortoenteric fistula (AEF), rare but devastating complications of aortic reconstructive surgery. Two observers independently reviewed CT scans in 55 cases including AEF (n = 23); PGI (n = 12); and normal, noninfected grafts (n = 20). Each scan was assessed for ectopic gas, focal bowel wall thickening, perigraft fluid, perigraft soft tissue, pseudoaneurysm formation, disruption of the aneurysmal wrap, and increased soft tissue between the graft and surrounding wrap. Comparison of CT findings with operative results revealed that each observer correctly identified as abnormal 33 of 35 cases of PGI either with or without AEF (sensitivity, 94%) and that results were falsely positive in three cases (specificity, 85%). CT findings ranged from large amounts of perigraft soft tissue and ectopic gas to subtle findings of minimal or no abnormalities; thus, strict criteria must be applied to the interpretation of CT scans after aortic surgery. Although CT is not 100% sensitive or specific, the authors conclude that it will continue to be valuable for diagnosing PGI and AEF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wanhainen, A., Verzini, F., Van Herzeele, I., Allaire, E., Bown, M., Cohnert, T., Dick, F., van Herwaarden, J., Karkos, C., Koelemay, M., et al. (2019) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.09.020 · Cited by 2,326
Isselbacher, E. M., Preventza, O., Hamilton Black, J., Augoustides, J. G., Beck, A. W., Bolen, M. A., Braverman, A. C., Bray, B. E., Brown-Zimmerman, M. M., Chen, E. P., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001106 · Cited by 2,082
Moll, F. L., Powell, J. T., Fraedrich, G., Verzini, F., Haulon, S., Waltham, M., van Herwaarden, J. A., Holt, P. J. E., van Keulen, J. W., Rantner, B., et al. (2011) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2010.09.011 · Cited by 1,468
2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease
Isselbacher, E. M., Preventza, O., Hamilton Black III, J., Augoustides, J. G., Beck, A. W., Bolen, M. A., Braverman, A. C., Bray, B. E., Brown-Zimmerman, M. M., Chen, E. P., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.08.004 · Cited by 619
Metadata
- Authors
- Low, R. N., Wall, S. D., Jeffrey, R. B., Sollitto, R. A., Reilly, L. M., & Tierney, L. M.
- Venue
- Radiology
- Published
- 1990-04
- Volume
- 175
- Issue
- 1
- Pages
- 157-162
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2079934762
- Cited by
- 191
- References
- 0
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aortoenteric fistula and perigraft infection: evaluation with CT. https://app.cochat.ai/papers/10.1148/radiology.175.1.2315475
- The paper
- Low, R. N., Wall, S. D., Jeffrey, R. B., Sollitto, R. A., Reilly, L. M., & Tierney, L. M. (1990). Aortoenteric fistula and perigraft infection: evaluation with CT. Radiology. https://doi.org/10.1148/radiology.175.1.2315475
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.