Multichannel biomagnetic system for study of electrical activity in the brain and heart
The DOI matches its Crossref record.
Abstract
The authors designed a multichannel system for noninvasive measurement of the extremely weak magnetic fields generated by the brain and the heart. It uses a flat array of 37 superconducting magnetic field-sensing coils connected to sophisticated superconducting quantum interference devices. To prevent interference from external electromagnetic fields, the system is operated inside a shielded room. Complete sets of coherent data, even from spontaneous events, can be recorded. System performance was evaluated with phantom measurements and evoked-response studies. A spatial resolution of a few millimeters and a temporal resolution of a millisecond were obtained. First results in patients with partial epilepsy and investigations of the cardiac conductive pathway indicate that biomagnetism is now ready for a systematic clinical evaluation. Interpretation of measurements was facilitated by highlighting biomagnetically localized electrical activity in three-dimensional digital magnetic resonance images.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Still being checked.
Cited by
Infectious Diseases: Preparing for the Future
King, D. A., Peckham, C., Waage, J. K., Brownlie, J., & Woolhouse, M. E. J. (2006) · Science · doi:10.1126/science.1129134 · Cited by 251
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
Stefan, H., Schneider, S., Feistel, H., Pawlik, G., Schüler, P., Abraham‐Fuchs, K., Schlegel, T., Neubauer, U., & Huk, W. J. (1992) · Epilepsia · doi:10.1111/j.1528-1157.1992.tb02195.x · Cited by 149
Self-citationA new wearable multichannel magnetocardiogram system with a SERF atomic magnetometer array
Yang, Y., Xu, M., Liang, A., Yin, Y., Ma, X., Gao, Y., & Ning, X. (2021) · Scientific Reports · doi:10.1038/s41598-021-84971-7 · Cited by 146
Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer
Kim, Y. J., Savukov, I., & Newman, S. (2019) · Applied Physics Letters · doi:10.1063/1.5094339 · Cited by 133
Metadata
- Authors
- Schneider, S., Hoenig, E., Reichenberger, H., Abraham-Fuchs, K., Moshage, W., Oppelt, A., Stefan, H., Weikl, A., & Wirth, A.
- Affiliations
- Siemens (Germany) (DE)
- ORCID
- Stefan, H
- Venue
- Radiology
- Published
- 1990-09
- Volume
- 176
- Issue
- 3
- Pages
- 825-830
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1995356440
- Cited by
- 74
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 4 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 1
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- biomagnetism, magnetoencephalography, magnetocardiography, squid, multichannel measurement system, electromagnetic interference shielding, evoked potentials, epilepsy, cardiac conduction pathways, spatiotemporal resolution
- MeSH terms
- Brain, Electrocardiography, Electromagnetic Fields, Epilepsy, Temporal Lobe, Heart, Humans, Magnetic Resonance Imaging, Wolff-Parkinson-White Syndrome, Magnetoencephalography, Electromagnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multichannel biomagnetic system for study of electrical activity in the brain and heart. https://app.cochat.ai/papers/10.1148/radiology.176.3.2389043
- The paper
- Schneider, S., Hoenig, E., Reichenberger, H., Abraham-Fuchs, K., Moshage, W., Oppelt, A., Stefan, H., Weikl, A., & Wirth, A. (1990). Multichannel biomagnetic system for study of electrical activity in the brain and heart. Radiology. https://doi.org/10.1148/radiology.176.3.2389043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.