Multichannel biomagnetic system for study of electrical activity in the brain and heart
The DOI matches its Crossref record.
Abstract
The authors designed a multichannel system for noninvasive measurement of the extremely weak magnetic fields generated by the brain and the heart. It uses a flat array of 37 superconducting magnetic field-sensing coils connected to sophisticated superconducting quantum interference devices. To prevent interference from external electromagnetic fields, the system is operated inside a shielded room. Complete sets of coherent data, even from spontaneous events, can be recorded. System performance was evaluated with phantom measurements and evoked-response studies. A spatial resolution of a few millimeters and a temporal resolution of a millisecond were obtained. First results in patients with partial epilepsy and investigations of the cardiac conductive pathway indicate that biomagnetism is now ready for a systematic clinical evaluation. Interpretation of measurements was facilitated by highlighting biomagnetically localized electrical activity in three-dimensional digital magnetic resonance images.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Still being checked.
Cited by
Infectious Diseases: Preparing for the Future
King, D. A., Peckham, C., Waage, J. K., Brownlie, J., & Woolhouse, M. E. J. (2006) · Science · doi:10.1126/science.1129134 · Cited by 251
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
Stefan, H., Schneider, S., Feistel, H., Pawlik, G., Schüler, P., Abraham‐Fuchs, K., Schlegel, T., Neubauer, U., & Huk, W. J. (1992) · Epilepsia · doi:10.1111/j.1528-1157.1992.tb02195.x · Cited by 149
Self-citationA new wearable multichannel magnetocardiogram system with a SERF atomic magnetometer array
Yang, Y., Xu, M., Liang, A., Yin, Y., Ma, X., Gao, Y., & Ning, X. (2021) · Scientific Reports · doi:10.1038/s41598-021-84971-7 · Cited by 125
Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer
Kim, Y. J., Savukov, I., & Newman, S. (2019) · Applied Physics Letters · doi:10.1063/1.5094339 · Cited by 133
Sekihara, K., & Scholz, B. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.486285 · Cited by 86
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Event-synchronous cancellation of the heart interference in biomedical signals
Strobach, P., Abraham‐Fuchs, K., & Härer, W. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284962 · Cited by 72
Self-citationMultichannel DC SQUID sensor array for biomagnetic applications
Hoenig, H. E., Daalmans, G., Bär, L., Bömmel, F., Paulus, A., Uhl, D., Weisse, H., Schneider, S., Seifert, H., Reichenberger, H., et al. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133787 · Cited by 64
Self-citationBiomagnetism: The First Sixty Years
Roth, B. J. (2023) · Sensors · doi:10.3390/s23094218 · Cited by 68
Stefan, H., Schneider, S., Abraham‐Fuchs, K., Pawlik, G., Feistel, H., Bauer, J. M., Neubauer, U., Huk, W. J., & Holthoff‐Detto, V. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90150-3 · Cited by 49
Self-citationFang, X., Wei, K., Zhao, T., Zhai, Y., Ma, D., Xing, B., Liu, Y., & Xiao, Z. (2020) · Optics Express · doi:10.1364/oe.398540 · Cited by 49
The separation of overlapping neuromagnetic sources in first and second somatosensory cortices
Elbert, T. R., Jungh�fer, M., Scholz, B., & Schneider, S. (1995) · Brain Topography · doi:10.1007/bf01195253 · Cited by 55
Self-citationMoshage, W. E. L., Achenbach, S. S., Göhl, K., & Bachmann, K. F. (1996) · International journal of cardiac imaging · doi:10.1007/bf01798116 · Cited by 51
Self-citationSekihara, K., & Scholz, B. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.341827 · Cited by 38
LEDER, U., Pohl, H.-P., Michaelsen, S., Fritschi, T., Huck, M., Eichhorn, J., Müller, S., & Nowak, H. (1998) · International Journal of Cardiology · doi:10.1016/s0167-5273(97)00326-4 · Cited by 33
Hellstrand, E., Abraham‐Fuchs, K., Jernberg, B., Kihlström, L., KNUTSSON, E., Lindquist, C., Schneider, S., & Wirth, A. (1993) · Physiological Measurement · doi:10.1088/0967-3334/14/2/004 · Cited by 29
Self-citationAccurate Matching of electromagnetic dipole data with CT and MR images
van den Elsen, P. A., Viergever, M. A., van Huffelen, A. C., der Meij, W. V., & Wieneke, G. H. (1991) · Brain Topography · doi:10.1007/bf01129001 · Cited by 26
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Multimodality visualization of medical volume data
Zuiderveld, K. J., Koning, A. H. J., Stokking, R., Maintz, J. B. A., Appelman, F. J. R., & Viergever, M. A. (1996) · Computers & Graphics · doi:10.1016/s0097-8493(96)00050-7 · Cited by 26
Forty Years of Magnetocardiology
Stroink, G. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-12197-5_1 · Cited by 21
Magnetocardiography: clinical investigations with a biomagnetic multichannel system
Achenbach, S., & Moshage, W. (1993) · Physiological Measurement · doi:10.1088/0967-3334/14/4a/011 · Cited by 20
Self-citationA Single-Axis Atomic Magnetometer-Based Mouse Magnetocardiography Measurement System
Sun, Y., Xixi, W., Zhou, Y., Qin, J., Bai, D., Wang, Y., & Zhou, Z. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3265089 · Cited by 21
Biomagnetic Noninvasive Localization of Accessory Pathways in Wolff‐Parkinson‐White Syndrome
WEISMÜLLER, P., Abraham‐Fuchs, K., SCHNEIDER, S., RICHTER, P., Kochs, M., EDRICH, J., & Hombach, V. (1991) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1991.tb02798.x · Cited by 18
Self-citationIoannides, A. A., Hellstrand, E., & Abraham‐Fuchs, K. (1993) · Physiological Measurement · doi:10.1088/0967-3334/14/2/003 · Cited by 18
Self-citationWEISMÜLLER, P., RICHTER, P., Abraham‐Fuchs, K., Härer, W., SCHNEIDER, S., Höher, M., KOGHS, M., EDRICH, J., & Hombach, V. (1993) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1993.tb01537.x · Cited by 18
Self-citationClinical magnetocardiography: experience with a biomagnetic multichannel system
Moshage, W., Achenbach, S., Weikl, A., Göhl, K., Bachmann, K., Abraham-Fuchs, K., Härer, W., & Schneider, S. (1991) · The International Journal of Cardiac Imaging · doi:10.1007/bf01797754 · Cited by 17
“The system is based on 37 first-order gradiometers arranged in a planar array with a diameter of 19 cm [11].”
BackgroundMethodSelf-citationKillmann, R., Jaros, G. G., Wach, P., Graumann, R., Moshage, W. E. L., Renhardt, M., & Fleischmann, R. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510781 · Cited by 16
Self-citationBruder, H., Killmann, R., Moshage, W. E. L., WEISMÜLLER, P., Achenbach, S., & Bömmel, F. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/4/001 · Cited by 15
Self-citationHorigome, H., Tsukada, K., Kandori, A., Shiono, J., Matsui, A., Terada, Y., & Mitsui, T. (1999) · International journal of cardiac imaging · doi:10.1023/a:1006136525382 · Cited by 13
Hombach, V., Kochs, M., WEISMÜLLER, P., Clausen, M., Henze, E., Richter, P., Höher, M., Peper, A., Eggeling, T., Adam, W. E., et al. (1991) · International journal of cardiac imaging · doi:10.1007/bf01797755 · Cited by 13
Pl, A., Göranson, H., Hindmarsh, T., KNUTSSON, E., Mohlkert, D., Rosenqvist, M., & Bergfeldt, L. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712138 · Cited by 12
Magnetocardiographic and Electrocardiographic Mapping Studies
Stroink, G., Lamothe, M. J. R., & Gardner, M. J. (1996) · Springer eBooks · doi:10.1007/978-94-011-5674-5_10 · Cited by 12
Sekihara, K., Abraham‐Fuchs, K., Stefan, H., & Hellstrandt, E. (1996) · Brain Topography · doi:10.1007/bf01184792 · Cited by 10
Self-citationBiomedical Applications of Electromagnetic Engineering
Lin, J. C.-J. (2004) · CRC Press eBooks · doi:10.1201/9780203026021-20 · Cited by 9
Biomedical Applications of Electromagnetic Engineering
Lin, J. C.-J. (2004) · CRC Press eBooks · doi:10.1201/9780203026021.ch17 · Cited by 9
Multichannel magneto-electroencephalography recordings of interictal and ictal activity
Stefan, H., Abraham‐Fuchs, K., Schneider, S., Schüler, P., & Huk, W. J. (1993) · Physiological Measurement · doi:10.1088/0967-3334/14/4a/020 · Cited by 8
Self-citationClinical applications of MEG in epilepsy
Stefan, H. (1993) · Brain Topography · doi:10.1007/bf01128701 · Cited by 8
Self-citationReconstruction of the Electrical Structure of the Human Body Using Spectral Functional Tomography
Rykunov, S. D., Boyko, A. I., & Ustinin, M. N. (2023) · Pattern Recognition and Image Analysis · doi:10.1134/s1054661823040387 · Cited by 6
Non-dipolarity of Heart Potentials Estimated by Magnetocardiography in Normal Subjects.
Izumida, N., Asano, Y., Hosaki, J., Hiyoshi, Y., Sakurada, H., Motomiya, T., Kawano, S., Sawanobori, T., & Hiraoka, M. (1998) · Japanese Heart Journal · doi:10.1536/ihj.39.731 · Cited by 6
Neural networks for segmentation and clustering of biomagnetical signals
Schlang, M. F., Volker Tresp, C., Abraham‐Fuchs, K., Härer, W., & WEISMÜLLER, P. (2003) · Machine learning for signal processing ... · doi:10.1109/nnsp.1992.253678 · Cited by 6
Self-citationXing, B., Feng, X., & Zhang, B. (2025) · Sensors · doi:10.3390/s25196096 · Cited by 5
Reconstruction of the Human Heart Functional Structure Based On a Few-Channel Magnetocardiogram
Ustinin, M. N., Maslennikov, Y. V., Rykunov, S. D., & Krymov, V. A. (2018) · Mathematical Biology and Bioinformatics · doi:10.17537/2018.13.392 · Cited by 3
An iterative approach on magnetic source imaging within the human cortex — a simulation study
TILG, B., & Wach, P. (1995) · International Journal of Bio-Medical Computing · doi:10.1016/0020-7101(95)01141-z · Cited by 3
Biomagnetic multi‐channel systems. Principles and application in cardiology
Reichenberger, H., Schneider, S., Moshage, W. E. L., & Weismüllen, P. (1992) · Clinical Physiology · doi:10.1111/j.1475-097x.1992.tb00838.x · Cited by 2
Self-citationNew Trends in Clinical Magnetocardiography
Mäkijärvi, M. A., Brockmeier, K., LEDER, U., Lesh, M. D., Moshage, W. E. L., Nakaya, Y., Nenonen, J., Nowak, H., Oeff, M., Stroink, G., et al. (2000) · Springer eBooks · doi:10.1007/978-1-4612-1260-7_100 · Cited by 4
Self-citationCurrent trends in biomagnetic instrumentation
Schneider, S., Abraham‐Fuchs, K., Seifert, H., & Hoenig, H. E. (1993) · Applied Superconductivity · doi:10.1016/0964-1807(93)90329-z · Cited by 2
Self-citationBiomedical Applications of Electromagnetic Engineering
Lin, J. C.-J. (2006) · CRC Press eBooks · doi:10.1201/9781420007251.ch7 · Cited by 2
Barnes, J., Arsalani, S., Waterstraat, G., Curio, G., Radzinski, L., Haueisen, J., & Körber, R. (2026) · Scientific Reports · doi:10.1038/s41598-026-50113-0 · Cited by 1
Youn, T. J., Kim, Y. G., Oh, K. S., Piao, H., Kwon, J. S., Choi, S. Y., Kim, D. W., Cho, M., Lee, Y., & Kwon, H. (2002) · Korean Circulation Journal · doi:10.4070/kcj.2002.32.4.330 · Cited by 1
Magnetocardiographic Parameters for the Detection of Graft Rejection after Heart Transplantation
Achenbach, S. S., Moshage, W. E. L., Graf, S., Bachmann, K., & Permanetter, B. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1995.40.s1.303 · Cited by 1
Self-citationHeidari, H., & Nabaei, V. (2019) · Wiley eBooks · doi:10.1002/9781119552215.ch5 · Cited by 2
Biomagnetic sensing: technologies and applications
Guo, H., Wu, T., Sun, C., Zhao, B., & Yang, X. (2024) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2024-1029 · Cited by 1
Neural networks for reconstruction of focal events from bioelectric/biomagnetic potentials
Schlang, M. F., Haft, M., & Abraham‐Fuchs, K. (1994) · IEEE International Conference on Neural Networks/IEEE ... International Conference on Neural Networks · doi:10.1109/icnn.1994.374892 · Cited by 1
Self-citationSignalverarbeitung und Quellrekonstruktion beim Biomagnetismus
Oppelt, A., Abraham‐Fuchs, K., Graumann, R., Schneider, S., Scholz, B., & Strobach, P. (1991) · Springer eBooks · doi:10.1007/978-3-642-93501-5_14 · Cited by 1
Self-citationFetal Magnetocardiography with a Multichannel System: First Clinical Results
Achenbach, S. S., Moshage, W. E. L., Beinder, E., Bachmann, K. F., & Lang, N. (1994) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1994.39.s1.113 · Cited by 1
Self-citationLindquist, C. (1993) · Acta Neurochirurgica · doi:10.1007/bf01447001 · Cited by 1
Abraham‐Fuchs, K., & Sekihara, K. (1992) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1992.5762031 · Cited by 1
Self-citationTILG, B., Findner, I., Weger, I., & Wach, P. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1993.978415 · Cited by 1
Classification of biomagnetic field patterns by neural networks
Schlang, M. F., Neuneier, R., Abraham‐Fuchs, K., & Uebler, J. (2002) · Machine learning for signal processing ... · doi:10.1109/nnsp.1993.471830 · Cited by 1
Self-citationFunctional Diagnosis by Combining Biomagnetic Source Localization and Digital Images
Uebler, J., Abraham‐Fuchs, K., Gebhardt, M., Röhrlein, G., & Schneider, S. (1991) · Springer eBooks · doi:10.1007/978-3-662-00807-2_40 · Cited by 1
Self-citationVolker Tresp, C., Leuthäusser, I., Schlang, M. F., Neuneier, R., Abraham‐Fuchs, K., & Härer, W. (2003) · Machine learning for signal processing ... · doi:10.1109/nnsp.1992.253663 · Cited by 1
Self-citationMagnetokardiographische Spätfelddiagnostik. Gegenwärtiger Stand und Entwicklungsperspektiven
WEISMÜLLER, P. (1997) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/bf03042398 · Cited by 1
The Neural Impulse Response Filter
Volker Tresp, C., Leuthäusser, I., Schlang, M. F., Neuneier, R., Abraham‐Fuchs, K., & Härer, W. (1992) · Elsevier eBooks · doi:10.1016/b978-0-444-89488-5.50059-2 · Cited by 1
Self-citationDesign and Operation of a Biomagnetic Multichannel System
Schneider, S., Seifert, H., Hoenig, H. E., & Reichenberger, H. (1992) · Springer proceedings in physics · doi:10.1007/978-3-642-77457-7_86 · Cited by 1
Self-citationNeuronale Netze zur Segmentierung und Clusterung von biomagnetischen Signalen
Schlang, M. F., Volker Tresp, C., Härer, W., Abraham‐Fuchs, K., & WEISMÜLLER, P. (1992) · Informatik aktuell · doi:10.1007/978-3-642-77785-1_22
Self-citationRenhardt, M., Wach, P., Moshage, W. E. L., Dienstl, F., Killmann, R., Fleischmann, P., & TILG, B. (1993) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1993.38.s1.383
Self-citationPotentials and Limitations of Biomagnetic Measurements in Cardiology
Moshage, W. E. L., Achenbach, S. S., & Bachmann, K. F. (1994) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1994.39.s1.111
Self-citationOppelt, A., Graumann, R., & Scholz, B. (1993) · Zeitschrift für Medizinische Physik · doi:10.1016/s0939-3889(15)70713-0
Self-citationDesign and performance of a biomagnetic multichannel system for MEG and MCG studies
Schneider, S., & Abraham‐Fuchs, K. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/b/012
Self-citationDC-Messungen in der klinischen Magnetokardiographie
Moshage, W. E. L., Achenbach, S. S., Friedrich, M. G., Schneider, S., Helle, R., & Bachmann, K. F. (1991) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1991.36.s1.149
Self-citationMagnetokardiographische Lokalisationsdiagnositk — Gegenwärtiger Stand und Entwicklungsperspektiven
Moshage, W. E. L., Achenbach, S. S., & Bachmann, K. (1997) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/bf03042397
Self-citationThe Use of Magnetoencephalography in Psychiatry
Fenwick, P. B. C., Ioannides, A. A., & Lumsden, J. (1993) · Springer eBooks · doi:10.1007/978-3-642-77087-6_29
Abraham‐Fuchs, K., Stefan, H., Schueler, P., Uebler, J., Schneider, S., & Naser, G. (1994) · Springer eBooks · doi:10.1007/978-1-4615-2546-2_28
Self-citation
Metadata
- Authors
- Schneider, S., Hoenig, E., Reichenberger, H., Abraham-Fuchs, K., Moshage, W., Oppelt, A., Stefan, H., Weikl, A., & Wirth, A.
- Affiliations
- Siemens (Germany) (DE)
- ORCID
- Stefan, H
- Venue
- Radiology
- Published
- 1990-09
- Volume
- 176
- Issue
- 3
- Pages
- 825-830
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1995356440
- Cited by
- 74
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 4 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 1
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- biomagnetism, magnetoencephalography, magnetocardiography, squid, multichannel measurement system, electromagnetic interference shielding, evoked potentials, epilepsy, cardiac conduction pathways, spatiotemporal resolution
- MeSH terms
- Brain, Electrocardiography, Electromagnetic Fields, Epilepsy, Temporal Lobe, Heart, Humans, Magnetic Resonance Imaging, Wolff-Parkinson-White Syndrome, Magnetoencephalography, Electromagnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.