Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We have constructed a low-cost, portable, high-sensitivity 16-channel optically pumped magnetometer (OPM), operating in the spin-exchange relaxation-free regime, and demonstrated its applications in magnetocardiography (MCG). The decrease in the cost of sensors by an order of magnitude is achieved by the 16-channel operation realized in a single module using a single large flat pancake rubidium vapor cell, broad pump and probe laser beams, and a 16-channel photodiode array. The OPM is also based on a fiber-coupled nearly parallel-beam configuration to facilitate multichannel design and make the system portable. For human MCG experiments, the 16-channel OPM which includes optical components is placed inside a wooden enclosure for laser safety. The enclosure is set on a nonmagnetic table inside a magnetically shielded room, while the lasers and electronics are placed outside the shielding room, to avoid magnetic noise. We show that the 16-channel OPM enables simultaneous imaging of human cardiac activity on a large area of the chest in a single scan. The multichannel capability will accelerate clinical MCG imaging to reduce the procedure time and patient fatigue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The MCG measurements usually require the participant keeping still in a magnetically shielded room due to the immovable sensor and noisy external environments.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [36]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Previously, biomagnetic signal measurements based on OPMs are often performed in magnetically shielded environments (35, 36) due to the magnetic field noise from surroundings. Despite there being several works on unshielded biomagnetic signal measurements (35, 37), these shielded or unshielded measurements normally require the participant to remain still during the measurement.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [36]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
Seltzer, S. J., & Romalis, M. V. (2004) · Applied Physics Letters · doi:10.1063/1.1814434 · Cited by 320
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
A laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185
Multi-channel atomic magnetometer for magnetoencephalography: A configuration study
Kim, K., Begus, S., Xia, H., Lee, S.-K., Jazbinsek, V., Trontelj, Z., & Romalis, M. V. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.040 · Cited by 170
Multichannel biomagnetic system for study of electrical activity in the brain and heart
Schneider, S., Hoenig, E., Reichenberger, H., Abraham-Fuchs, K., Moshage, W., Oppelt, A., Stefan, H., Weikl, A., & Wirth, A. (1990) · Radiology · doi:10.1148/radiology.176.3.2389043 · Cited by 74
Kim, Y. J., Chu, P.-H., & Savukov, I. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.091802 · Cited by 67
Self-citation
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“Previously, biomagnetic signal measurements based on OPMs are often performed in magnetically shielded environments ( 35 , 36 ) due to the magnetic field noise from surroundings.”
Parameter Modeling Analysis of a Cylindrical Ferrite Magnetic Shield to Reduce Magnetic Noise
Ma, D., Lu, J., Fang, X., Yang, K., Wang, K., Zhang, N., Han, B., & Ding, M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3050351 · Cited by 99
Tang, J., Zhai, Y., Zhou, B., Han, B., & Liu, G. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3112797 · Cited by 102
Three-axis closed-loop optically pumped magnetometer operated in the SERF regime
Yan, Y., Lu, J., Zhang, S., Lu, F., Yin, K., Wang, K., Zhou, B., & Liu, G. (2022) · Optics Express · doi:10.1364/oe.458367 · Cited by 89
Tang, J., Liu, Y., Wang, Y., Zhou, B., Han, B., Zhai, Y., & Liu, G. (2022) · Applied Physics Letters · doi:10.1063/5.0080764 · Cited by 87
Metadata
- Authors
- Kim, Y. J., Savukov, I., & Newman, S.
- Affiliations
- Los Alamos National Laboratory (US)
- Corresponding author
- Kim, Young Jin
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2019-04-08
- Volume
- 114
- Issue
- 14
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2935860139
- Cited by
- 133
- References
- 15
- Citations by year
- 2026: 18 · 2025: 26 · 2024: 25 · 2023: 26 · 2022: 17 · 2021: 16 · 2020: 5
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor, 4 d)
- creativecommons.org/licenses/by/4.0/ (tdm, 4 d)
- Locations
- Applied Physics Letters (publishedVersion, cc-by)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- Los Alamos National Laboratory (20180131ER)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Keywords
- magnetocardiography, optically pumped magnetometers, rubidium vapor cell, spin-exchange relaxation-free, low-cost sensors, magnetic shielding
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer. https://app.cochat.ai/papers/10.1063/1.5094339
- The paper
- Kim, Y. J., Savukov, I., & Newman, S. (2019). Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer. Applied Physics Letters. https://doi.org/10.1063/1.5094339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.