CoChat

A new wearable multichannel magnetocardiogram system with a SERF atomic magnetometer array

Open access
Yang, Yanfei, Xu, Mingzhu, Liang, Aimin, Yin, Yan, Ma, Xin, Gao, Yang, Ning, Xiaolin · 2021 · Scientific Reports
Cited by 125

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

In this study, a wearable multichannel human magnetocardiogram (MCG) system based on a spin exchange relaxation-free regime (SERF) magnetometer array is developed. The MCG system consists of a magnetically shielded device, a wearable SERF magnetometer array, and a computer for data acquisition and processing. Multichannel MCG signals from a healthy human are successfully recorded simultaneously. Independent component analysis (ICA) and empirical mode decomposition (EMD) are used to denoise MCG data. MCG imaging is realized to visualize the magnetic and current distribution around the heart. The validity of the MCG signals detected by the system is verified by electrocardiogram (ECG) signals obtained at the same position, and similar features and intervals of cardiac signal waveform appear on both MCG and ECG. Experiments show that our wearable MCG system is reliable for detecting MCG signals and can provide cardiac electromagnetic activity imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-021-84971-7

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Research works printed but not linked: 21

  1. Kavuru, M. S., Vesselle, H. & Thomas, C. W. Pediatric and Fundamental Electrocardiography 315–327 (Springer, 1987). · doi:10.1007/978-1-4613-2323-5_15
  2. Medvegy, M., Duray, G., Pintér, A. & Préda, I. Body surface potential mapping: Historical background, present possibilities, diagnostic challenges. Ann. Noninvasive Electrocardiol. 7, 139–151 (2002). · DOI
  3. Kamada, K., Ito, Y. & Kobayashi, T. Human MCG measurements with a high-sensitivity potassium atomic magnetometer. Physiol. Meas. 33, 1063–1071 (2012). · DOI
  4. Koch, H. Recent advances in magnetocardiography. J. Electrocardiol. 37, 117–122 (2004). · DOI
  5. Yamada, S. & Yamaguchi, I. Magnetocardiograms in clinical medicine: Unique information on cardiac ischemia, arrhythmias, and fetal diagnosis. Intern. Med. 44, 1–19 (2005). · DOI · Paper page
  6. Morales, S. et al. Magnetocardiography measurements with 4He vector optically pumped magnetometers at room temperature. Phys. Med. Biol. 62, 7267 (2017). · DOI · Paper page
  7. Labyt, E. et al. Magnetoencephalography with optically pumped 4 he magnetometers at ambient temperature. IEEE Trans. Med. Imaging 38, 90–98 (2019). · DOI · Paper page
  8. Xia, H., Baranga, B. A., Hoffman, D. & Romalis, M. V. Magnetoencephalography with an atomic magnetometer. Appl. Phys. Lett. 89, 664 (2006).
  9. Bison, G., Wynands, R. & Weis, A. A laser-pumped magnetometer for the mapping of human cardiomagnetic fields. Appl. Phys. B 76, 325–328 (2003). · DOI · Paper page
  10. Lembke, G. et al. Optical multi-channel room temperature magnetic field imaging system for clinical application. Biomed. Opt. Express 5, 876–881 (2014). · DOI · Paper page
  11. Wyllie, R., Kauer, M., Smetana, G. S., Wakai, R. T. & Walker, T. G. Magnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array. Phys. Med. Biol. 57, 2619–2632. https://doi.org/10.1088/0031-9155/57/9/2619 (2012). · DOI · Paper page
  12. Kimball, D. J., Alexandrov, E. & Budker, D. General principles and characteristics of optical magnetometers. Opt. Magnetometry 3, 20 (2013).
  13. Bison, G. et al. A room temperature 19-channel magnetic field mapping device for cardiac signals. Appl. Phys. Lett. 95, 173701 (2009). · DOI · Paper page
  14. Alem, O. et al. Fetal magnetocardiography measurements with an array of microfabricated optically pumped magnetometers. Phys. Med. Biol. 60, 4797 (2015). · DOI · Paper page
  15. Bison, G. Development of an Optical Cardio-magnetometer (Université de Fribourg, Fribourg, 2004).
  16. Mariyappa, N. et al. Denoising of multi-channel MCG data by the combination of EEMD and ICA and its effect on the pseudo current density maps. Biomed. Signal Process. Control 18, 204–213 (2015). · DOI
  17. Hyvarinen, A. Fast and robust fixed-point algorithms for independent component analysis. IEEE Trans. Neural Netw. 10, 626 (1999). · DOI · Paper page
  18. Kopsinis, Y. & Mclaughlin, S. Development of EMD-based denoising methods inspired by wavelet thresholding. IEEE Trans. Signal Process. 57, 1351–1362 (2009). · DOI · Paper page
  19. Cohen, D. & Hosaka, H. Part II magnetic field produced by a current dipole. J. Electrocardiol. 9, 409–417 (1976). · DOI
  20. Haberkorn, W. et al. Pseudo current density maps of electrophysiological heart, nerve or brain function and their physical basis. Biomagn. Res. Technol. 4, 1–18 (2006). · DOI
  21. Jiang, S., Yu, J. & Wu, L. In IEEE Engineering in Medicine and Biology 27th Annual Conference. 4381–4384 (2005).

Cited by

See all 125

Metadata

Authors
Yang, Y., Xu, M., Liang, A., Yin, Y., Ma, X., Gao, Y., & Ning, X.
Venue
Scientific Reports
Published
2021-03-10
Volume
11
Issue
1
Pages
5564-5564
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3134664738
Cited by
125
References
9
FWCI
7.56
Type
journal article
Language
en
Open access
gold
Licence
Funders
Beijing Academy of Quantum Information Sciences (BAQIS) Research Program (25400LZ2019117002)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A new wearable multichannel magnetocardiogram system with a SERF atomic magnetometer array. https://app.cochat.ai/papers/10.1038/s41598-021-84971-7
The paper
Yang, Y., Xu, M., Liang, A., Yin, Y., Ma, X., Gao, Y., & Ning, X. (2021). A new wearable multichannel magnetocardiogram system with a SERF atomic magnetometer array. Scientific Reports. https://doi.org/10.1038/s41598-021-84971-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.