Focal liver lesions: MR imaging with Mn-DPDP--initial clinical results in 40 patients.
The DOI matches its Crossref record.
Abstract
Manganese (II) N,N'-dipyridoxylethylenediamine-N,N'-diacetate-5,5'-bis(phosphate) (DPDP) was evaluated as a contrast agent for magnetic resonance (MR) imaging (1.5 T) of focal liver lesions in 40 patients. Doses of 5 and 10 mumol/kg were administered intravenously. Mn-DPDP-enhanced T1-weighted images were compared quantitatively and subjectively with standard T1- and T2-weighted nonenhanced images. Use of Mn-DPDP resulted in a statistically significant increase in signal intensity of liver parenchyma in T1-weighted images at both doses. No enhancement was seen in metastases, cholangiocarcinomas, or lymphomas, while all hepatocellular carcinomas were enhanced. Enhancement was seen in focal nodular hyperplasia and in regenerative nodules. The lesion-to-liver contrast in Mn-DPDP-enhanced gradient-recalled-echo images was superior to that of all precontrast images (P less than .01). The number of nonenhancing malignant liver lesions detected in spin-echo (SE) images was increased (272 in T2-weighted SE images vs 390 in T1-weighted Mn-DPDP-enhanced SE images). Image interpretation (eg, visualization and demarcation of the lesions) was markedly better in Mn-DPDP-enhanced images than in all precontrast images (P less than .001).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rohrer, M., Bauer, H., Mintorovitch, J., Requardt, M., & Weinmann, H.-J. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000184756.66360.d3 · Cited by 1,682
Kinkel, K., Lu, Y., Both, M., Warren, R. S., & Thoeni, R. F. (2002) · Radiology · doi:10.1148/radiol.2243011362 · Cited by 621
A Manganese Alternative to Gadolinium for MRI Contrast
Gale, E. M., Atanasova, I. P., Blasi, F., Ay, I., & Caravan, P. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b10748 · Cited by 353
Effects of Magnetic Fluid Hyperthermia (MFH) on C3H mammary carcinoma in vivo
Jordan, A., Scholz, R., Wust, P., Fähling, H., Krause, J., Wlodarczyk, W., Sander, B., Vogl, T., & Felix, R. (1997) · International Journal of Hyperthermia · doi:10.3109/02656739709023559 · Cited by 325
Self-citationReimer, P., Schneider, G., & Schima, W. (2004) · European Radiology · doi:10.1007/s00330-004-2236-1 · Cited by 287
Metal Compounds in Therapy and Diagnosis
Abrams, M. J., & Murrer, B. A. (1993) · Science · doi:10.1126/science.8102010 · Cited by 281
Hamm, B., Staks, T., Taupitz, M., Maibauer, R., Speidel, A., Huppertz, A., Frenzel, T., Lawaczeck, R., Wolf, K. J., & Lange, L. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040508 · Cited by 187
Detection of hepatic metastasis: manganese-and ferucarbotran-enhanced MR imaging
Choi, J.-Y., Kim, M.-J., Kim, J. H., Kim, S. H., Ko, H.-K., Lim, J. S., Oh, Y. T., Chung, J.-J., Yoo, H. S., Lee, J. T., et al. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.016 · Cited by 29
Metadata
- Authors
- Hamm, B., Vogl, T. J., Branding, G., Schnell, B., Taupitz, M., Wolf, K. J., & Lissner, J.
- Venue
- Radiology
- Published
- 1992-01
- Volume
- 182
- Issue
- 1
- Pages
- 167-174
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2027070588
- Cited by
- 175
- References
- 0
- FWCI
- 14.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.