The DOI matches its Crossref record.
MP RAGE: a three-dimensional, T1-weighted, gradient-echo sequence--initial experience in the brain.
Abstract
The authors evaluated a recently developed sequence for magnetic resonance imaging of the brain. The three-dimensional, Fourier-transformed acquisitions require magnetization-prepared 180 degrees radio-frequency pulses and rapid gradient-echo (MP RAGE) sampling. The resulting T1-weighted images were compared with T1-weighted spin-echo (SE) images; both were obtained after paramagnetic contrast material was administered to 33 patients with known or suspected focal brain lesions. Image quality and contrast between gray and white matter were superior with the MP RAGE sequence compared with the T1-weighted SE sequence. The time for obtaining contiguous thin-section (1.3-2.5-mm) images was also comparable, with readily acquired multiplanar reformations obviating additional images. MP RAGE imaging depicted more focal lesions than did T1-weighted SE imaging and matched the number seen with T2-weighted SE imaging. Demonstration of paramagnetic contrast enhancement of lesions was comparable in most cases; however, three lesions showed greater enhancement on T1-weighted SE images and two others were seen only on the T1-weighted SE images. Thus, the MP RAGE sequence may provide an alternative to T1-weighted SE imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the Brain
Mugler, J. P., Bao, S., Mulkern, R. V., Guttmann, C. R. G., Robertson, R. L., Jolesz, F. A., & Brookeman, J. R. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au46891 · Cited by 334
Magnetic resonance imaging for the diagnosis of Parkinson’s disease
Heim, B., Krismer, F., De Marzi, R., & Seppi, K. (2017) · Journal of Neural Transmission · doi:10.1007/s00702-017-1717-8 · Cited by 272
Regional Differences in the CBF and BOLD Responses to Hypercapnia: A Combined PET and fMRI Study
Rostrup, E., Law, I., Blinkenberg, M., Larsson, H. B. W., Born, A. P., Holm, S., & Paulson, O. B. (2000) · NeuroImage · doi:10.1006/nimg.1999.0526 · Cited by 216
A tool for functional brain imaging with lifespan compliance
Hill, R. M., Boto, E., Holmes, N., Hartley, C., Seedat, Z. A., Leggett, J., Roberts, G., Shah, V., Tierney, T. M., Woolrich, M. W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12486-x · Cited by 180
White matter integrity in physically fit older adults.
Tseng, B. Y., Gundapuneedi, T., Khan, M. A., Diaz-Arrastia, R., Levine, B. D., Lu, H., Huang, H., & Zhang, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.011 · Cited by 157
Metadata
- Authors
- Brant-Zawadzki, M., Gillan, G. D., & Nitz, W. R.
- Venue
- Radiology
- Published
- 1992-03
- Volume
- 182
- Issue
- 3
- Pages
- 769-775
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1982325931
- Cited by
- 342
- References
- 0
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MP RAGE: a three-dimensional, T1-weighted, gradient-echo sequence--initial experience in the brain. https://app.cochat.ai/papers/10.1148/radiology.182.3.1535892
- The paper
- Brant-Zawadzki, M., Gillan, G. D., & Nitz, W. R. (1992). MP RAGE: a three-dimensional, T1-weighted, gradient-echo sequence--initial experience in the brain. Radiology. https://doi.org/10.1148/radiology.182.3.1535892
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.