The DOI matches its Crossref record.
Multisection proton MR spectroscopic imaging of the brain.
Abstract
The authors developed a hydrogen-1 proton magnetic resonance (MR) imaging method in which metabolic information is acquired by obtaining multiple sections through the brain. A spin-echo sequence is used for section selection, an octangular outer volume saturation pulse for lipid suppression, and a chemical-shift-selective saturation pulse for water suppression. High-quality maps of choline, creatine, and N-acetylaspartate were obtained in six studies performed in four volunteers. Water and lipid signal from the skull area was well suppressed by the pulse sequence used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Miller, D. H., Albert, P. S., Barkhof, F., Francis, G., Frank, J. A., Hodgkinson, S., Lublin, F. D., Paty, D. W., Reingold, S. C., & Simon, J. (1996) · Annals of Neurology · doi:10.1002/ana.410390104 · Cited by 444
Variation in GRM3 affects cognition, prefrontal glutamate, and risk for schizophrenia
Egan, M. F., Straub, R. E., Goldberg, T. E., Yakub, I., Callicott, J. H., Hariri, A. R., Mattay, V. S., Bertolino, A., Hyde, T. M., Shannon-Weickert, C., et al. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405077101 · Cited by 416
Quantitative proton MR spectroscopic imaging of the human brain
Soher, B. J., van Zijl, P. C. M., Duyn, J. H., & Barker, P. B. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350313 · Cited by 271
Self-citationLapteva, L., Nowak, M., Yarboro, C. H., Takada, K., Roebuck‐Spencer, T., Weickert, T., Bleiberg, J., Rosenstein, D., Pao, M., Patronas, N., et al. (2006) · Arthritis & Rheumatism · doi:10.1002/art.22031 · Cited by 258
Hao, X., Xu, D., Bansal, R., Dong, Z., Liu, J., Wang, Z., Kangarlu, A., Liu, F., Duan, Y., Shova, S., et al. (2013) · Human Brain Mapping · doi:10.1002/hbm.21440 · Cited by 63
Metadata
- Authors
- Duyn, J. H., Gillen, J., Sobering, G., van Zijl, P. C., & Moonen, C. T.
- Venue
- Radiology
- Published
- 1993-07
- Volume
- 188
- Issue
- 1
- Pages
- 277-282
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2099018998
- Cited by
- 356
- References
- 0
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multisection proton MR spectroscopic imaging of the brain. https://app.cochat.ai/papers/10.1148/radiology.188.1.8511313
- The paper
- Duyn, J. H., Gillen, J., Sobering, G., van Zijl, P. C., & Moonen, C. T. (1993). Multisection proton MR spectroscopic imaging of the brain. Radiology. https://doi.org/10.1148/radiology.188.1.8511313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.