The DOI matches its Crossref record.
Evaluation of left ventricular volume and mass with breath-hold cine MR imaging.
Abstract
Left ventricular (LV) volumes and mass were evaluated in 10 healthy volunteers with breath-hold cine magnetic resonance (MR) imaging. The results were compared with those obtained with conventional cine MR imaging. The breath-hold studies showed no ghosting artifact, and cardiac edges were clearly identified because of the reduced blurring. Measurements of LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), and LV mass obtained with breath-hold cine MR imaging showed close correlation with those obtained with conventional cine MR imaging (r = .98, .97, and .99, respectively). The interobserver variabilities for LVEDV, LVESV, and LV mass determined with breath-hold cine MR imaging (4.0%, 8.0%, and 3.7%, respectively) were equal to or less than those determined with conventional cine MR imaging (4.0%, 8.6%, and 5.0%, respectively). The authors conclude that breath-hold cine MR imaging is highly useful because an accurate assessment of cardiac function is obtained in less than 5 minutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Koskenvuo, J. W., Karra, H., Lehtinen, J., Niemi, P., Pärkkä, J., Knuuti, J., & Hartiala, J. J. (2007) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00764.x · Cited by 28
Self-citation
Metadata
- Authors
- Sakuma, H., Fujita, N., Foo, T. K., Caputo, G. R., Nelson, S. J., Hartiala, J., Shimakawa, A., & Higgins, C. B.
- Venue
- Radiology
- Published
- 1993-08
- Volume
- 188
- Issue
- 2
- Pages
- 377-380
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2023089297
- Cited by
- 262
- References
- 0
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of left ventricular volume and mass with breath-hold cine MR imaging. https://app.cochat.ai/papers/10.1148/radiology.188.2.8327681
- The paper
- Sakuma, H., Fujita, N., Foo, T. K., Caputo, G. R., Nelson, S. J., Hartiala, J., Shimakawa, A., & Higgins, C. B. (1993). Evaluation of left ventricular volume and mass with breath-hold cine MR imaging. Radiology. https://doi.org/10.1148/radiology.188.2.8327681
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.