Evaluation of left ventricular volume and mass with breath-hold cine MR imaging.
The DOI matches its Crossref record.
Abstract
Left ventricular (LV) volumes and mass were evaluated in 10 healthy volunteers with breath-hold cine magnetic resonance (MR) imaging. The results were compared with those obtained with conventional cine MR imaging. The breath-hold studies showed no ghosting artifact, and cardiac edges were clearly identified because of the reduced blurring. Measurements of LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), and LV mass obtained with breath-hold cine MR imaging showed close correlation with those obtained with conventional cine MR imaging (r = .98, .97, and .99, respectively). The interobserver variabilities for LVEDV, LVESV, and LV mass determined with breath-hold cine MR imaging (4.0%, 8.0%, and 3.7%, respectively) were equal to or less than those determined with conventional cine MR imaging (4.0%, 8.6%, and 5.0%, respectively). The authors conclude that breath-hold cine MR imaging is highly useful because an accurate assessment of cardiac function is obtained in less than 5 minutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alfakih, K., Plein, S., Thiele, H., Jones, T., Ridgway, J. P., & Sivananthan, M. U. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10262 · Cited by 732
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Bellenger, N., Davies, L. C., Francis, J., Coats, A., & Pennell, D. (2000) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976640009148691 · Cited by 681
Gender differences and normal left ventricular anatomy in an adult population free of hypertension
Salton, C. J., Chuang, M. L., O’Donnell, C. J., Kupka, M. J., Larson, M. G., Kissinger, K. V., Edelman, R. R., Levy, D., & Manning, W. J. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01712-6 · Cited by 359
Malm, S., Frigstad, S., Sagberg, E., Larsson, H., & Skjaerpe, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.068 · Cited by 323
Moon, J. C. C., Lorenz, C. H., Francis, J. M., Smith, G. C., & Pennell, D. J. (2002) · Radiology · doi:10.1148/radiol.2233011181 · Cited by 294
Chuang, M. L., Hibberd, M. G., Salton, C. J., Beaudin, R. A., Riley, M. F., Parker, R. A., Douglas, P. S., & Manning, W. J. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00551-3 · Cited by 272
Plein, S., Bloomer, T. N., Ridgway, J. P., Jones, T. R., Bainbridge, G. J., & Sivananthan, M. U. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1178 · Cited by 257
Cardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“This is known as segmented k-space gradient echo imaging, as k-space is segmented into a series of groups of lines [28, 29], and is sometimes referred to as multiple shot imaging.”
Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE
Feng, L., Srichai, M. B., Lim, R. P., Harrison, A., King, W., Adluru, G., Dibella, E. V. R., Sodickson, D. K., Otazo, R., & Kim, D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24440 · Cited by 232
Assessment of ventricular function and mass by cardiac magnetic resonance imaging
Alfakih, K., Reid, S., Jones, T., & Sivananthan, M. (2004) · European Radiology · doi:10.1007/s00330-004-2387-0 · Cited by 225
“TGE acquisition has been compared to previously validated sequences with excellent correlation, and SSFP imaging was recently validated in animal studies [16, 30].”
MethodCardiovascular magnetic resonance physics for clinicians: part I
Ridgway, J. P. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-71 · Cited by 218
“This is known as segmented k-space gradient echo imaging, as k-space is segmented into a series of groups of lines [28,29], and is sometimes referred to as multiple shot imaging.”
Ventricular Volume and Mass by CMR
Pennell, D. J. (2003) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120016389 · Cited by 169
Accelerating cardiac cine MRI using a deep learning‐based ESPIRiT reconstruction
Sandino, C. M., Lai, P., Vasanawala, S. S., & Cheng, J. Y. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28420 · Cited by 161
“If all N coil sensitivity maps (S) can be reliably estimated from calibration data, then a SENSE4 PI reconstruction x̂ can be directly obtained from y using the least squares solution to Equation (1).”
BackgroundMethodInfluentialKoskenvuo, J. W., Karra, H., Lehtinen, J., Niemi, P., Pärkkä, J., Knuuti, J., & Hartiala, J. J. (2007) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00764.x · Cited by 28
Self-citation
Metadata
- Authors
- Sakuma, H., Fujita, N., Foo, T. K., Caputo, G. R., Nelson, S. J., Hartiala, J., Shimakawa, A., & Higgins, C. B.
- Venue
- Radiology
- Published
- 1993-08
- Volume
- 188
- Issue
- 2
- Pages
- 377-380
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2023089297
- Cited by
- 262
- References
- 0
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.