Echo-planar imaging of the liver with a standard MR imaging system.
The DOI matches its Crossref record.
Abstract
PURPOSE: A multisection, whole-body echo-planar imaging (EPI) sequence was developed to obtain T2-weighted images of the liver in one 18-second breath hold with a standard magnetic resonance (MR) imaging system. MATERIALS AND METHODS: This capability was achieved by dividing the data acquisition period into eight interleaved segments rather than one or two as implemented previously with EPI systems having high-power gradient subsystems. RESULTS: The interleaved echo-planar images had excellent depiction of anatomy and no identifiable respiratory artifact. In 26 lesions in 12 patients, the eight-shot echo-planar images (2,000/66 [repetition time msec/echo time msec]) had superior contrast compared with conventional T2-weighted spin-echo (SE) images (2,500/60) by an average factor of 1.22 +/- 0.31 (standard deviation) and an average contrast-to-noise ratio relative to conventional T2-weighted SE images of 0.85 +/- 0.22. CONCLUSION: With a conventional MR imaging system, breath-hold T2-weighted echo-planar images of the liver are comparable in diagnostic quality to conventional T2-weighted SE images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577
Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes
Butts, K., de Crespigny, A., Pauly, J. M., & Moseley, M. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350518 · Cited by 244
Self-citationCoenegrachts, K., Delanote, J., Ter Beek, L., Haspeslagh, M., Bipat, S., Stoker, J., Van Kerkhove, F., Steyaert, L., Rigauts, H., & W Casselman, J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/33156643 · Cited by 149
Invited. Ultrafast MR imaging of the abdomen: Echo planar imaging and diffusion‐weighted imaging
Yamashita, Y., Tang, Y., & Takahashi, M. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080216 · Cited by 92
Metadata
- Authors
- Butts, K., Riederer, S. J., Ehman, R. L., Felmlee, J. P., & Grimm, R. C.
- Venue
- Radiology
- Published
- 1993-10
- Volume
- 189
- Issue
- 1
- Pages
- 259-264
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2122903528
- Cited by
- 89
- References
- 0
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Echo-planar imaging of the liver with a standard MR imaging system. https://app.cochat.ai/papers/10.1148/radiology.189.1.8396785
- The paper
- Butts, K., Riederer, S. J., Ehman, R. L., Felmlee, J. P., & Grimm, R. C. (1993). Echo-planar imaging of the liver with a standard MR imaging system. Radiology. https://doi.org/10.1148/radiology.189.1.8396785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.