Initial clinical experience in MR imaging of the brain with a fast fluid-attenuated inversion-recovery pulse sequence.
The DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate fast fluid-attenuated inversion-recovery (FLAIR) technique for imaging brain abnormalities. MATERIALS AND METHODS: A fast FLAIR sequence was developed that provided 36 5-mm contiguous sections in 5 minutes 8 seconds. Resulting images were compared with dual-echo T2-weighted spin-echo images of 41 consecutive patients with brain abnormalities. RESULTS: Contrast and contrast-to-noise ratios (C/Ns) (for contrast between the lesion and background and between the lesion and cerebrospinal fluid) for fast FLAIR exceeded the corresponding values for T2-weighted spin-echo images for all but the second-echo lesion-to-background C/N. Fast FLAIR provided equivalent or greater overall lesion conspicuity and enabled greater lesion detection in 98% and 100%, respectively, of the evaluations. Fast FLAIR images more often had image artifact, but this did not interfere with image interpretation in a significantly (P < or = .05) greater number of evaluations. CONCLUSION: Fast FLAIR provides images that are superior to proton-density- and T2-weighted images for many image quality criteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of magnetic resonance techniques in understanding and managing multiple sclerosis
Miller, D. (1998) · Brain · doi:10.1093/brain/121.1.3 · Cited by 556
Miller, D. H., Albert, P. S., Barkhof, F., Francis, G., Frank, J. A., Hodgkinson, S., Lublin, F. D., Paty, D. W., Reingold, S. C., & Simon, J. (1996) · Annals of Neurology · doi:10.1002/ana.410390104 · Cited by 444
Cross sectional analysis of mortality by country of birth in england and wales, 1970-92
Wild, S., & Mckeigue, P. (1997) · BMJ · doi:10.1136/bmj.314.7082.705 · Cited by 421
MR Imaging Findings in Hepatic Encephalopathy
Rovira, A., Alonso, J., & Córdoba, J. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1139 · Cited by 358
Optimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the Brain
Mugler, J. P., Bao, S., Mulkern, R. V., Guttmann, C. R. G., Robertson, R. L., Jolesz, F. A., & Brookeman, J. R. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au46891 · Cited by 334
Thomalla, G., Rossbach, P., Rosenkranz, M., Siemonsen, S., Krützelmann, A., Fiehler, J., & Gerloff, C. (2009) · Annals of Neurology · doi:10.1002/ana.21651 · Cited by 248
Bakshi, R., Ariyaratana, S., Benedict, R. H. B., & Jacobs, L. (2001) · Archives of Neurology · doi:10.1001/archneur.58.5.742 · Cited by 216
Grimaud, J., Lai, M., Thorpe, J., Adeleine, P., Wang, L., Barker, G. J., Plummer, D. L., Tofts, P. S., McDonald, W. I., & Miller, D. H. (1996) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(96)00018-5 · Cited by 205
Brain Aging in Very Old Men With Type 2 Diabetes
Korf, E. S. C., White, L. R., Scheltens, P., & Launer, L. J. (2006) · Diabetes Care · doi:10.2337/dc06-0243 · Cited by 191
Hirono, N., Kitagaki, H., Kazui, H., Hashimoto, M., & Mori, E. (2000) · Stroke · doi:10.1161/01.str.31.9.2182 · Cited by 186
Filippi, M., Baratti, C., Yousry, T., Horsfield, M. A., Mammi, S., Becker, C., Voltz, R., Spuler, S., Campi, A., Reiser, M. F., et al. (1996) · Brain · doi:10.1093/brain/119.4.1349 · Cited by 177
“…et al., 1992; Bergin et ai, 1993; De Coene et al., 1993; Schwieso et al., 1993; Thomas et al., 1993; Bradley et al., 1994; Litt and Moore, 1994; Rydberg et al., 1994; Thorpe et al., 1994; Baratti et al., 1995; Hashemi et al., 1995; M. Filippi et al. combining a long inversion time inversion…”
FLAIR histogram segmentation for measurement of leukoaraiosis volume
Jack, C. R., O'Brien, P. C., Rettman, D. W., Shiung, M. M., Xu, Y., Muthupillai, R., Manduca, A., Avula, R., & Erickson, B. J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10011 · Cited by 176
Self-citationAtrophy rates accelerate in amnestic mild cognitive impairment
Jack, C. R., Weigand, S. D., Shiung, M. M., Przybelski, S. A., O’Brien, P. C., Gunter, J. L., Knopman, D. S., Boeve, B. F., Smith, G. E., & Petersen, R. C. (2008) · Neurology · doi:10.1212/01.wnl.0000281688.77598.35 · Cited by 176
Self-citationMRI of head injury using FLAIR
Ashikaga, R., Araki, Y., & Ishida, O. (1997) · Neuroradiology · doi:10.1007/s002340050401 · Cited by 173
“The fast FLAIR sequence, which yields 18 sections in a short acquisition time, can overcome these difficulties [10].”
BackgroundImaging of Acute Cerebral Ischemia
Beauchamp, N. J., Barker, P. B., Wang, P. Y., & vanZijl, P. C. M. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au16307 · Cited by 169
Imaging of White Matter Lesions
Barkhof, F., & Scheltens, P. (2002) · Cerebrovascular Diseases · doi:10.1159/000049146 · Cited by 161
Butts, K., Pauly, J., De Crespigny, A., & Moseley, M. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380510 · Cited by 160
Metadata
- Authors
- Rydberg, J. N., Hammond, C. A., Grimm, R. C., Erickson, B. J., Jack, C. R., Huston, J., & Riederer, S. J.
- Venue
- Radiology
- Published
- 1994-10
- Volume
- 193
- Issue
- 1
- Pages
- 173-180
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2128885141
- Cited by
- 268
- References
- 0
- FWCI
- 21.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.