The DOI matches its Crossref record.
Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient.
Abstract
PURPOSE: To determine the relationship between the apparent diffusion coefficient (ADC) and renal function. MATERIALS AND METHODS: Twenty-three volunteers and seven pigs underwent diffusion-sensitive magnetic resonance (MR) imaging of the kidneys with a stimulated-echo acquisition mode excitation and echo-planar imaging readout under various physiologic conditions. The effect of hydration and anisotropic diffusion was studied in human subjects, and the effect of renal artery stenosis, ureteral obstruction, and diuresis was studied in the animal model. RESULTS: The renal ADC values of dehydrated subjects were substantially increased with rehydration. Diffusion was highest in the medulla, with a pronounced radial component in the renal collecting system. In the pig model, induced renal artery stenosis resulted in immediate decrease in renal ADC; the degree of change was related to the flow deficit. The ADC also decreased with ureteral obstruction, but diuresis had no meaningful effect. CONCLUSION: In vivo measurement of ADC has the potential for use as a noninvasive means to explore the functional status of the kidney.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Kwee, T. C., Takahara, T., Ochiai, R., Nievelstein, R. A. J., & Luijten, P. R. (2008) · European Radiology · doi:10.1007/s00330-008-0968-z · Cited by 410
Renal Lesions: Characterization with Diffusion-weighted Imaging versus Contrast-enhanced MR Imaging
Taouli, B., Thakur, R. K., Mannelli, L., Babb, J. S., Kim, S., Hecht, E. M., Lee, V. S., & Israel, G. M. (2009) · Radiology · doi:10.1148/radiol.2512080880 · Cited by 322
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456953 · Cited by 314
Metadata
- Authors
- Müller, M. F., Prasad, P. V., Bimmler, D., Kaiser, A., & Edelman, R. R.
- Venue
- Radiology
- Published
- 1994-12
- Volume
- 193
- Issue
- 3
- Pages
- 711-715
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2085601824
- Cited by
- 181
- References
- 0
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. https://app.cochat.ai/papers/10.1148/radiology.193.3.7972811
- The paper
- Müller, M. F., Prasad, P. V., Bimmler, D., Kaiser, A., & Edelman, R. R. (1994). Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. Radiology. https://doi.org/10.1148/radiology.193.3.7972811
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.