Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 322

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Renal Lesions: Characterization with Diffusion-weighted Imaging versus Contrast-enhanced MR Imaging

Taouli, Bachir, Thakur, Ravi K., Mannelli, Lorenzo, Babb, James S., Kim, Sooah, Hecht, Elizabeth M., Lee, Vivian S., Israel, Gary M.·2009·Radiology

Abstract

PURPOSE: To compare the diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging with that of contrast material-enhanced (CE) MR imaging and to assess the performance of these examinations combined for the characterization of renal lesions, with MR follow-up and histopathologic analysis as the reference standards. MATERIALS AND METHODS: The institutional review board waived the requirement of informed patient consent for this retrospective HIPAA-compliant study. One hundred nine renal lesions in 64 patients (46 men, 18 women; mean age, 60.7 years) were evaluated with CE MR imaging and breath-hold DW imaging performed with various b values. Renal lesions were characterized with use of CE MR criteria, and apparent diffusion coefficients (ADCs) were measured. The ADCs of benign and malignant lesions were compared at Mann-Whitney testing. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of DW imaging and CE MR imaging in the diagnosis of renal cell carcinoma (RCC). RESULTS: The 109 renal lesions--81 benign lesions and 28 RCCs--had a mean diameter of 4.2 cm +/- 2.5 (standard deviation). The mean ADC for RCCs (1.41 x 10(-3) mm(2)/sec +/- 0.61) was significantly lower (P < .0001) than that for benign lesions (2.23 x 10(-3) mm(2)/sec +/- 0.87) at DW imaging performed with b values of 0, 400, and 800 sec/mm(2). At a cutoff ADC of less than or equal to 1.92 x 10(-3) mm(2)/sec, the area under the ROC curve (AUC), sensitivity, and specificity of DW imaging for the diagnosis of RCCs (excluding angiomyolipomas) were 0.856, 86%, and 80%, respectively. The corresponding AUC, sensitivity, and specificity of CE MR imaging were 0.944, 100%, and 89%, respectively. Combined DW and CE MR imaging had 96% specificity. The AUC for the DW imaging-based diagnosis of solid RCC versus oncocytoma was 0.854. Papillary RCCs had lower ADCs than nonpapillary RCCs. CONCLUSION: DW imaging can be used to characterize renal lesions; however, compared with CE MR imaging, it is less accurate. DW imaging can be used to differentiate solid RCCs from oncocytomas and characterize the histologic subtypes of RCC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2512080880

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 322

Metadata

Authors
Taouli, B., Thakur, R. K., Mannelli, L., Babb, J. S., Kim, S., Hecht, E. M., Lee, V. S., & Israel, G. M.
Venue
Radiology
Published
2009-05
Volume
251
Issue
2
Pages
398-407
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2135223702
Cited by
322
References
33
FWCI
20.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Renal Lesions: Characterization with Diffusion-weighted Imaging versus Contrast-enhanced MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.2512080880
The paper
Taouli, B., Thakur, R. K., Mannelli, L., Babb, J. S., Kim, S., Hecht, E. M., Lee, V. S., & Israel, G. M. (2009). Renal Lesions: Characterization with Diffusion-weighted Imaging versus Contrast-enhanced MR Imaging. Radiology. https://doi.org/10.1148/radiol.2512080880

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.