Adnexal masses: accuracy of characterization with transvaginal US and precontrast and postcontrast MR imaging.
The DOI matches its Crossref record.
Abstract
PURPOSE: To determine the accuracy of transvaginal ultrasound (TVUS) and of precontrast and contrast material-enhanced magnetic resonance (MR) imaging in the differentiation of adnexal masses. MATERIALS AND METHODS: Five blinded readers analyzed images of 80 masses in 72 patients. MR and TVUS images were interpreted in separate sessions. Findings were confirmed at surgery or laparoscopy. RESULTS: Higher diagnostic accuracy was attained with MR imaging in mature cystic teratomas and endometriomas. However, better accuracy was achieved with contrast-enhanced MR imaging and TVUS in simple cysts, cystadenomas, and malignant tumors because internal details could be visualized. Receiver operating characteristic study indicated that observer confidence was significantly higher with contrast-enhanced MR imaging than with precontrast MR imaging (P = .011) or TVUS (P = .002) in the differentiation of benign and malignant masses. CONCLUSION: Contrast-enhanced MR imaging is superior to precontrast MR and TVUS imaging in the characterization and differentiation of adnexal masses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
Imaging Evaluation of Ovarian Masses
Jeong, Y.-Y., Outwater, E. K., & Kang, H. K. (2000) · RadioGraphics · doi:10.1148/radiographics.20.5.g00se101445 · Cited by 410
Complex Adnexal Masses: Detection and Characterization with MR Imaging—Multivariate Analysis
Hricak, H., Chen, M., Coakley, F. V., Kinkel, K., Yu, K. K., Sica, G., Bacchetti, P., & Powell, C. B. (2000) · Radiology · doi:10.1148/radiology.214.1.r00ja3939 · Cited by 294
Kinkel, K., Lu, Y., Mehdizade, A., Pelte, M.-F., & Hricak, H. (2005) · Radiology · doi:10.1148/radiol.2361041618 · Cited by 280
Kurtz, A. B., Tsimikas, J. V., Tempany, C. M. C., Hamper, U. M., Arger, P. H., Bree, R. L., Wechsler, R. J., Francis, I. R., Kuhlman, J. E., Siegelman, E. S., et al. (1999) · Radiology · doi:10.1148/radiology.212.1.r99jl3619 · Cited by 267
Metadata
- Authors
- Yamashita, Y., Torashima, M., Hatanaka, Y., Harada, M., Higashida, Y., Takahashi, M., Mizutani, H., Tashiro, H., Iwamasa, J., & Miyazaki, K.
- Venue
- Radiology
- Published
- 1995-02
- Volume
- 194
- Issue
- 2
- Pages
- 557-565
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2077633325
- Cited by
- 155
- References
- 0
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adnexal masses: accuracy of characterization with transvaginal US and precontrast and postcontrast MR imaging. https://app.cochat.ai/papers/10.1148/radiology.194.2.7824738
- The paper
- Yamashita, Y., Torashima, M., Hatanaka, Y., Harada, M., Higashida, Y., Takahashi, M., Mizutani, H., Tashiro, H., Iwamasa, J., & Miyazaki, K. (1995). Adnexal masses: accuracy of characterization with transvaginal US and precontrast and postcontrast MR imaging. Radiology. https://doi.org/10.1148/radiology.194.2.7824738
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.