The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Focused US system for MR imaging-guided tumor ablation.
Abstract
PURPOSE: To measure the performance characteristics of a focused ultrasound (US) system for magnetic resonance (MR) imaging-guided tumor ablation. MATERIALS AND METHODS: The authors constructed a focused US system for MR imaging-guided tumor ablation. The location of the heated region and thermal dose were monitored with temperature-sensitive MR images obtained in phantoms and rabbit skeletal muscle after application of each sonic pulse. RESULTS: The region heated by the focused ultrasound beam was within 1 mm of that observed on temperature-sensitive fast gradient-echo MR images of in vivo rabbit skeletal muscle. Analysis of heat flow and the rate of coagulation necrosis provided an estimate of the size of the ablated region that was in agreement with experimental findings. CONCLUSION: MR imaging provides target definition and control for thermal therapy in regions of variable perfusion or in tissues that are not well characterized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MRI‐guided noninvasive ultrasound surgery
Hynynen, K., Darkazanli, A., Unger, E., & Schenck, J. F. (1993) · Medical Physics · doi:10.1118/1.597093 · Cited by 327
Self-citationTumor irradiation with intense ultrasound
Fry, F. J., & Johnson, L. K. (1978) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(78)90022-4 · Cited by 154
Modeling and observation of temperature changes in Vivo using MRI
Young, I., Hand, J. W., Oatridge, A., & Prior, M. V. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320311 · Cited by 109
Cited by
Goldberg, S. N., Gazelle, G. S., & Mueller, P. R. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.2.1740323 · Cited by 1,062
High intensity focused ultrasound: Physical principles and devices
ter Haar, >., & Coussios, C. (2007) · International Journal of Hyperthermia · doi:10.1080/02656730601186138 · Cited by 805
MR Imaging-guided Focused Ultrasound Surgery of Fibroadenomas in the Breast: A Feasibility Study
Hynynen, K., Pomeroy, O., Smith, D. N., Huber, P. E., McDannold, N. J., Kettenbach, J., Baum, J., Singer, S., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap02176 · Cited by 634
Self-citationMolecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Izadifar, Z., Izadifar, Z., Chapman, D., & Babyn, P. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020460 · Cited by 457
Metadata
- Authors
- Cline, H. E., Hynynen, K., Watkins, R. D., Adams, W. J., Schenck, J. F., Ettinger, R. H., Freund, W. R., Vetro, J. P., & Jolesz, F. A.
- Venue
- Radiology
- Published
- 1995-03
- Volume
- 194
- Issue
- 3
- Pages
- 731-737
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2048002169
- Cited by
- 276
- References
- 3
- FWCI
- 14.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Focused US system for MR imaging-guided tumor ablation. https://app.cochat.ai/papers/10.1148/radiology.194.3.7862971
- The paper
- Cline, H. E., Hynynen, K., Watkins, R. D., Adams, W. J., Schenck, J. F., Ettinger, R. H., Freund, W. R., Vetro, J. P., & Jolesz, F. A. (1995). Focused US system for MR imaging-guided tumor ablation. Radiology. https://doi.org/10.1148/radiology.194.3.7862971
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.