The DOI matches its Crossref record.
Diaphragmatic motion: fast gradient-recalled-echo MR imaging in healthy subjects.
Abstract
PURPOSE: To investigate the feasibility of imaging diaphragmatic motion with a fast gradient-recalled-echo (GRE) magnetic resonance (MR) pulse sequence. MATERIALS AND METHODS: Fast GRE pulse sequences in sagittal and coronal planes were used to acquire repeated, single-level, 1.2-second scans in 10 healthy volunteers during deliberately slowed, approximate-vital-capacity breathing. Motion was analyzed subjectively by viewing the image sequences as cine loops and quantitatively by measuring the displacement of different points on the diaphragm at a workstation. RESULTS: Temporal and spatial resolutions were adequate in all subjects. Absolute excursion of the domes was 4.4 cm on the right and 4.2 cm on the left. Analysis of diaphragmatic displacement at different locations revealed a gradient of excursion that increased from anterior to middle to posterior (P < .05-.001; paired t test). Excursion of the lateral aspects was greater than that of the medial aspect (P < .001). CONCLUSION: Fast GRE MR imaging can be reliably used to demonstrate diaphragmatic motion and may prove useful in the investigation of normal and abnormal respiratory mechanics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neuromuscular ultrasound for evaluation of the diaphragm
Sarwal, A., Walker, F. O., & Cartwright, M. S. (2013) · Muscle & Nerve · doi:10.1002/mus.23671 · Cited by 350
Imaging of the Diaphragm: Anatomy and Function
Nason, L. K., Walker, C. M., McNeeley, M. F., Burivong, W., Fligner, C. L., & Godwin, J. D. (2012) · RadioGraphics · doi:10.1148/rg.322115127 · Cited by 341
Ultrasonographic evaluation of diaphragmatic motion.
Gerscovich, E. O., Cronan, M., McGahan, J. P., Jain, K., Jones, C. D., & McDonald, C. (2001) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2001.20.6.597 · Cited by 312
Diaphragm postural function analysis using magnetic resonance imaging
Vostatek, P., Novák, D., Rychnovský, T., & Rychnovská, Š. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056724 · Cited by 81
Metadata
- Authors
- Gierada, D. S., Curtin, J. J., Erickson, S. J., Prost, R. W., Strandt, J. A., & Goodman, L. R.
- Venue
- Radiology
- Published
- 1995-03
- Volume
- 194
- Issue
- 3
- Pages
- 879-884
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2047282941
- Cited by
- 169
- References
- 0
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diaphragmatic motion: fast gradient-recalled-echo MR imaging in healthy subjects. https://app.cochat.ai/papers/10.1148/radiology.194.3.7862995
- The paper
- Gierada, D. S., Curtin, J. J., Erickson, S. J., Prost, R. W., Strandt, J. A., & Goodman, L. R. (1995). Diaphragmatic motion: fast gradient-recalled-echo MR imaging in healthy subjects. Radiology. https://doi.org/10.1148/radiology.194.3.7862995
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.