Clinical safety of gadopentetate dimeglumine.
Abstract
PURPOSE: To quantify the rate of adverse reactions to gadopentetate dimeglumine. MATERIALS AND METHODS: Magnetic resonance (MR) imaging was performed in 15,496 patients in April-September 1992. Data were collected before and after intravenous administration of 0.1 mmol/kg gadopentetate dimeglumine. RESULTS: Adverse reactions occurred in 2.4% (n = 372) of patients. Symptoms abated the same or next day in 94.1% (n = 350). Whereas onset occurred within 30 minutes after injection in 49.7% (n = 185), onset occurred more than 1 hour after injection in 44.9% (n = 167). Two serious adverse reactions occurred and were attributed to underlying disease. The rate of adverse reaction was 3.7% in patients with a history of asthma (31 of 831 patients) or allergy (144 of 3,860 patients). Patients with previous reactions to an MR imaging or iodinated contrast agent had an adverse-reaction rate in this study of 21.3% (16 of 75) and 6.3% (54 of 857), respectively. The rate of adverse reaction was 2.2% when gadopentetate dimeglumine was administered slowly and 2.9% when it was administered rapidly. CONCLUSION: Findings confirm the safety of gadopentetate dimeglumine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Safety of magnetic resonance imaging contrast agents
Shellock, F. G., & Kanal, E. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<477::aid-jmri33>3.0.co;2-e · Cited by 321
Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta.
Prince, M. R., Narasimham, D. L., Jacoby, W. T., Williams, D. M., Cho, K. J., Marx, M. V., & Deeb, G. M. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.6.8633452 · Cited by 296
Ersoy, H., & Rybicki, F. J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21135 · Cited by 283
Clinical applications of iron oxide nanoparticles for magnetic resonance imaging of brain tumors
Iv, M., Telischak, N., Feng, D., Holdsworth, S. J., Yeom, K. W., & Daldrup-Link, H. E. (2015) · Nanomedicine · doi:10.2217/nnm.14.203 · Cited by 134
Clinical Safety and Diagnostic Value of the Gadolinium Chelate Gadoterate Meglumine (Gd-DOTA)
Herborn, C. U., Honold, E., Wolf, M., Kemper, J., Kinner, S., Adam, G., & Barkhausen, J. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000248893.01067.e5 · Cited by 126
Metadata
- Authors
- Nelson, K. L., Gifford, L. M., Lauber-Huber, C., Gross, C. A., & Lasser, T. A.
- Venue
- Radiology
- Published
- 1995-08
- Volume
- 196
- Issue
- 2
- Pages
- 439-443
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2067516124
- Cited by
- 223
- References
- 0
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical safety of gadopentetate dimeglumine. https://app.cochat.ai/papers/10.1148/radiology.196.2.7617858
- The paper
- Nelson, K. L., Gifford, L. M., Lauber-Huber, C., Gross, C. A., & Lasser, T. A. (1995). Clinical safety of gadopentetate dimeglumine. Radiology. https://doi.org/10.1148/radiology.196.2.7617858
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.