The DOI matches its Crossref record.
Suspected multiple sclerosis: MR imaging with a thin-section fast FLAIR pulse sequence.
Abstract
PURPOSE: To compare thin-section, sagittal, fast fluid-attenuated inversion-recovery (FLAIR) magnetic resonance (MR) imaging with conventional axial spin-echo (SE) imaging for early detection of multiple sclerosis (MS) in the brain. MATERIALS AND METHODS: Conventional 5-mm axial proton-density- and T2-weighted SE images and sagittal 2-mm fast FLAIR images of the brain in five healthy volunteers and 25 patients with clinically suspected MS were evaluated and graded as normal or as showing possible or probable MS in a double-blind study. RESULTS: Fast FLAIR was judged better than SE in 37% of cases, equal to SE in 63%, and never worse than SE. In 43% of patients considered to have normal SE images, fast FLAIR images showed abnormalities consistent with MS. A subependymal striated appearance observed in several cases is believed to represent early inflammation and/or demyelination around subependymal veins in MS. CONCLUSION: Sagittal thin-section fast FLAIR is superior to conventional axial proton-density- and T2-weighted SE pulse sequences for detection of MS plaques in the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Barkhof, F. (1997) · Brain · doi:10.1093/brain/120.11.2059 · Cited by 1,251
Cross sectional analysis of mortality by country of birth in england and wales, 1970-92
Wild, S., & Mckeigue, P. (1997) · BMJ · doi:10.1136/bmj.314.7082.705 · Cited by 421
The contribution of magnetic resonance imaging to the diagnosis of multiple sclerosis
Fazekas, F., Barkhof, F., Filippi, M., Grossman, R. I., Li, D. K. B., McDonald, W. I., McFarland, H. F., Paty, D. W., Simon, J. H., Wolinsky, J. S., et al. (1999) · Neurology · doi:10.1212/wnl.53.3.448 · Cited by 287
Garg, N., Reddel, S. W., Miller, D. H., Chataway, J., Riminton, D. S., Barnett, Y., Masters, L., Barnett, M. H., & Hardy, T. A. (2015) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2014-309649 · Cited by 76
Metadata
- Authors
- Hashemi, R. H., Bradley, W. G., Chen, D. Y., Jordan, J. E., Queralt, J. A., Cheng, A. E., & Henrie, J. N.
- Venue
- Radiology
- Published
- 1995-08
- Volume
- 196
- Issue
- 2
- Pages
- 505-510
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2023572692
- Cited by
- 174
- References
- 0
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Suspected multiple sclerosis: MR imaging with a thin-section fast FLAIR pulse sequence. https://app.cochat.ai/papers/10.1148/radiology.196.2.7617868
- The paper
- Hashemi, R. H., Bradley, W. G., Chen, D. Y., Jordan, J. E., Queralt, J. A., Cheng, A. E., & Henrie, J. N. (1995). Suspected multiple sclerosis: MR imaging with a thin-section fast FLAIR pulse sequence. Radiology. https://doi.org/10.1148/radiology.196.2.7617868
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.