The DOI matches its Crossref record.
Superparamagnetic iron oxide--enhanced versus gadolinium-enhanced MR imaging for differential diagnosis of focal liver lesions.
Abstract
PURPOSE: To assess AMI-25- versus gadolinium-enhanced magnetic resonance (MR) imaging in the differential diagnosis of liver tumors. MATERIALS AND METHODS: Twenty-nine patients with liver tumors underwent unenhanced, AMI-25-enhanced (15 micromol/kg), and gadolinium-enhanced(0.1 mmol/kg) imaging within 2 weeks. RESULTS: A significant (P< .05) difference in percentage signal intensity loss (PSIL) was seen in benign tumors on AMI-25-enhanced proton-density-weighted images (nine focal nodular hyperplasia [FNH], 41%; one adenoma, 32.4%) versus malignant tumors. Gadolinium-enhanced T1-weighted gradient-echo images showed strong enhancement in benign lesions (seven FNH, 147.5%; one adenoma, 91.3%) and moderate enhancement in malignant tumors (eight hepatocellular carcinomas, 116.2%, 11 metastases, 39.7%). Receiver operating characteristic analysis revealed a threshold PSIL of 10% on AMI-25-enhanced images as the most essential criteria to distinguish benign from malignant lesions (sensitivity, 88%; specificity. 89%). Interobserver analysis for two observers revealed specificity of 93% for AMI-25-enhanced imaging versus 81.5% for gadolinium-enhanced MR imaging. CONCLUSION: AMI-25 decreased the SI of benign tumors and helped differentiate benign from malignant tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Superparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Superparamagnetic iron oxide based MRI contrast agents: Current status of clinical application.
Wáng, Y. X. J. (2011) · PubMed · doi:10.3978/j.issn.2223-4292.2011.08.03 · Cited by 613
Grazioli, L., Morana, G., Kirchin, M. A., & Schneider, G. (2005) · Radiology · doi:10.1148/radiol.2361040338 · Cited by 354
Metadata
- Authors
- Vogl, T. J., Hammerstingl, R., Schwarz, W., Mack, M. G., Müller, P. K., Pegios, W., Keck, H., Eibl-Eibesfeldt, A., Hoelzl, J., Woessmer, B., Bergman, C., & Felix, R.
- Venue
- Radiology
- Published
- 1996-03
- Volume
- 198
- Issue
- 3
- Pages
- 881-887
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2077387095
- Cited by
- 186
- References
- 0
- FWCI
- 19.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Superparamagnetic iron oxide--enhanced versus gadolinium-enhanced MR imaging for differential diagnosis of focal liver lesions. https://app.cochat.ai/papers/10.1148/radiology.198.3.8628887
- The paper
- Vogl, T. J., Hammerstingl, R., Schwarz, W., Mack, M. G., Müller, P. K., Pegios, W., Keck, H., Eibl-Eibesfeldt, A., Hoelzl, J., Woessmer, B., Bergman, C., & Felix, R. (1996). Superparamagnetic iron oxide--enhanced versus gadolinium-enhanced MR imaging for differential diagnosis of focal liver lesions. Radiology. https://doi.org/10.1148/radiology.198.3.8628887
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.