Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record.

Adrenal masses: correlation between CT attenuation value and chemical shift ratio at MR imaging with in-phase and opposed-phase sequences.

Outwater, E K, Siegelman, E S, Huang, A B, Birnbaum, B A·1996·Radiology

Abstract

PURPOSE: To correlate attenuation values at computed tomography (CT) with signal intensity at chemical-shift magnetic resonance (MR) imaging in adrenal masses. MATERIALS AND METHODS: Thirty-eight patients with 47 adrenal lesions underwent MR imaging and unenhanced CT examinations. MR examinations, performed at 1.5 T, included T1-weighted imaging with fat and water in phase and gradient-echo imaging with fat and water out of phase (repetition time, 45-180 msec; echo time, 1.4-3.1 msec). Lesion-to-spleen signal intensity ratios were calculated for the in-phase and opposed-phase images. The chemical-shift ratio, a measure of signal intensity loss between in-phase and opposed-phase images, and the CT attenuation value (in Hounsfield units) were determined for each lesion. RESULTS: A statistically significant correlation (0.85) was found between attenuation and chemical-shift-ratio values (P < .000001). Attenuation in six benign lesions was within 2 standard deviations of the mean attenuation in malignant lesions, and the chemical-shift ratio in eight benign lesions was within 2 standard deviations of the mean chemical-shift ratio in malignant lesions. Six of these eight lesions were misclassified on the basis of both attenuation and chemical-shift-ratio values. CONCLUSION: CT attenuation values are highly correlated with chemical-shift ratios. Both values were indeterminate for a similar subset of benign lesions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.200.3.8756926

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
Outwater, E. K., Siegelman, E. S., Huang, A. B., & Birnbaum, B. A.
Venue
Radiology
Published
1996-09
Volume
200
Issue
3
Pages
749-752
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2001918457
Cited by
192
References
0
FWCI
6.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adrenal masses: correlation between CT attenuation value and chemical shift ratio at MR imaging with in-phase and opposed-phase sequences. https://app.cochat.ai/papers/10.1148/radiology.200.3.8756926
The paper
Outwater, E. K., Siegelman, E. S., Huang, A. B., & Birnbaum, B. A. (1996). Adrenal masses: correlation between CT attenuation value and chemical shift ratio at MR imaging with in-phase and opposed-phase sequences. Radiology. https://doi.org/10.1148/radiology.200.3.8756926

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.