Adrenal masses: correlation between CT attenuation value and chemical shift ratio at MR imaging with in-phase and opposed-phase sequences.
The DOI matches its Crossref record.
Abstract
PURPOSE: To correlate attenuation values at computed tomography (CT) with signal intensity at chemical-shift magnetic resonance (MR) imaging in adrenal masses. MATERIALS AND METHODS: Thirty-eight patients with 47 adrenal lesions underwent MR imaging and unenhanced CT examinations. MR examinations, performed at 1.5 T, included T1-weighted imaging with fat and water in phase and gradient-echo imaging with fat and water out of phase (repetition time, 45-180 msec; echo time, 1.4-3.1 msec). Lesion-to-spleen signal intensity ratios were calculated for the in-phase and opposed-phase images. The chemical-shift ratio, a measure of signal intensity loss between in-phase and opposed-phase images, and the CT attenuation value (in Hounsfield units) were determined for each lesion. RESULTS: A statistically significant correlation (0.85) was found between attenuation and chemical-shift-ratio values (P < .000001). Attenuation in six benign lesions was within 2 standard deviations of the mean attenuation in malignant lesions, and the chemical-shift ratio in eight benign lesions was within 2 standard deviations of the mean chemical-shift ratio in malignant lesions. Six of these eight lesions were misclassified on the basis of both attenuation and chemical-shift-ratio values. CONCLUSION: CT attenuation values are highly correlated with chemical-shift ratios. Both values were indeterminate for a similar subset of benign lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The clinically inapparent adrenal mass: update in diagnosis and management
Mansmann, G., Lau, J., Balk, E., Rothberg, M., Miyachi, Y., & Bornstein, S. R. (2004) · Endocrine Reviews · doi:10.1210/er.2002-0031 · Cited by 781
“Chemical-shift MRI does not provide additional information beyond what is already available on unenhanced CT, but MRI may also be useful in ambiguous cases.”
InfluentialAdrenocortical Carcinoma: Clinical Update
Allolio, B., & Fassnacht, M. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-2639 · Cited by 775
Incidental Adrenal Lesions: Principles, Techniques, and Algorithms for Imaging Characterization
Boland, G. W. L., Blake, M. A., Hahn, P. F., & Mayo-Smith, W. W. (2008) · Radiology · doi:10.1148/radiol.2493070976 · Cited by 381
State-of-the-Art Adrenal Imaging
Mayo-Smith, W. W., Boland, G. W., Noto, R. B., & Lee, M. J. (2001) · RadioGraphics · doi:10.1148/radiographics.21.4.g01jl21995 · Cited by 359
Szolar, D. H., Korobkin, M., Reittner, P., Berghold, A., Bauernhofer, T., Trummer, H., Schoellnast, H., Preidler, K. W., & Samonigg, H. (2005) · Radiology · doi:10.1148/radiol.2342031876 · Cited by 314
Imaging of Adrenal Incidentalomas: Current Status
Dunnick, N. R., & Korobkin, M. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.3.1790559 · Cited by 307
Chemical Shift MR Imaging of Hyperattenuating (>10 HU) Adrenal Masses: Does It Still Have a Role?
Haider, M. A., Ghai, S., Jhaveri, K., & Lockwood, G. (2004) · Radiology · doi:10.1148/radiol.2313030676 · Cited by 278
Hepatic Fat Fraction: MR Imaging for Quantitative Measurement and Display—Early Experience
Hussain, H. K., Chenevert, T. L., Londy, F. J., Gulani, V., Swanson, S. D., McKenna, B. J., Appelman, H. D., Adusumilli, S., Greenson, J. K., & Conjeevaram, H. S. (2005) · Radiology · doi:10.1148/radiol.2373041639 · Cited by 277
Adrenal Masses: MR Imaging Features with Pathologic Correlation
Elsayes, K. M., Mukundan, G., Narra, V. R., Lewis, J. S., Shirkhoda, A., Farooki, A., & Brown, J. J. (2004) · RadioGraphics · doi:10.1148/rg.24si045514 · Cited by 261
Blake, M. A., Cronin, C. G., & Boland, G. W. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4547 · Cited by 253
Semelka, R. C., Armao, D. M., Elias, J., & Huda, W. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20895 · Cited by 238
Comparison of Unenhanced CT and Chemical Shift MRI in Evaluating Lipid-Rich Adrenal Adenomas
Israel, G. M., Korobkin, M., Wang, C., Hecht, E. N., & Krinsky, G. A. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.1.1830215 · Cited by 236
Management of adrenocortical carcinoma
Allolio, B., Hahner, S., Weismann, D., & Fassnacht, M. (2004) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2003.01881.x · Cited by 214
Lockhart, M. E., Smith, J. K., & Kenney, P. J. (2002) · European Journal of Radiology · doi:10.1016/s0720-048x(01)00444-2 · Cited by 211
TSUI, K.-H., SHVARTS, O., BARBARIC, Z., FIGLIN, R., de KERNION, J. B., & BELLDEGRUN, A. (2000) · Journal of Urology · doi:10.1016/s0022-5347(05)67895-0 · Cited by 168
Chidiac, R. M., & Aron, D. C. (1997) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(05)70242-5 · Cited by 140
Characterization of lipid-poor adrenal adenoma: chemical-shift MRI and washout CT
Seo, J. M., Park, B. K., Park, S. Y., & Kim, C. K. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11389 · Cited by 130
“Previous studies [10, 19] have reported that the role of MRI in characterizing lipid-poor adrenal masses is limited because of the S en si ti vi ty ( % )”
Background
Metadata
- Authors
- Outwater, E. K., Siegelman, E. S., Huang, A. B., & Birnbaum, B. A.
- Venue
- Radiology
- Published
- 1996-09
- Volume
- 200
- Issue
- 3
- Pages
- 749-752
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2001918457
- Cited by
- 192
- References
- 0
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.