The DOI matches its Crossref record.
Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography.
Abstract
PURPOSE: To prospectively compare the diagnostic accuracy of computed tomography (CT) during arterial portography (CTAP) with that of unenhanced and ferumoxides-enhanced magnetic resonance (MR) imaging at 0.5 T in the detection of hepatic metastases. MATERIALS AND METHODS: Four pairs of radiologists independently assessed the metastatic involvement of 134 hepatic segments (31 with and 103 without metastasis) in 17 patients at unenhanced and ferumoxides-enhanced spin-echo and gradient-echo MR imaging (alone and in combination) and at CTAP. The diagnostic performance of the various imaging modalities was assessed by means of receiver operating characteristic analysis. RESULTS: The accuracy of CTAP, unenhanced MR imaging (combined unenhanced sequences), and ferumoxides-enhanced MR imaging (combined contrast material-enhanced sequences) was 0.925, 0.908, and 0.951, respectively. Ferumoxides-enhanced MR imaging was significantly more accurate (P < .05) than unenhanced MR imaging and CTAP. When 14 segments containing cysts were excluded, the difference between ferumoxides-enhanced MR imaging and CTAP was no longer statistically significant (P = .1). CONCLUSION: Ferumoxides-enhanced MR imaging is more accurate than unenhanced MR imaging and at least as accurate as CTAP for the detection of hepatic metastases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Chen, F., Ward, J., & Robinson, P. J. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00193-3 · Cited by 44
Detection of hepatic metastasis: manganese-and ferucarbotran-enhanced MR imaging
Choi, J.-Y., Kim, M.-J., Kim, J. H., Kim, S. H., Ko, H.-K., Lim, J. S., Oh, Y. T., Chung, J.-J., Yoo, H. S., Lee, J. T., et al. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.016 · Cited by 29
Matsuo, M., Kanematsu, M., Itoh, K., Murakami, T., Maetani, Y., Kondo, H., Goshima, S., Kako, N., Hoshi, H., Konishi, J., et al. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.1.1820235 · Cited by 17
Metadata
- Authors
- Senéterre, E., Taourel, P., Bouvier, Y., Pradel, J., Van Beers, B., Daures, J. P., Pringot, J., Mathieu, D., & Bruel, J. M.
- Venue
- Radiology
- Published
- 1996-09
- Volume
- 200
- Issue
- 3
- Pages
- 785-792
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2059907075
- Cited by
- 310
- References
- 0
- FWCI
- 19.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography. https://app.cochat.ai/papers/10.1148/radiology.200.3.8756932
- The paper
- Senéterre, E., Taourel, P., Bouvier, Y., Pradel, J., Van Beers, B., Daures, J. P., Pringot, J., Mathieu, D., & Bruel, J. M. (1996). Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography. Radiology. https://doi.org/10.1148/radiology.200.3.8756932
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.