Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
The DOI matches its Crossref record.
Abstract
PURPOSE: To compare low-dose spiral computed tomography (CT) with radiography of the chest for the screening and detection of small peripheral lung cancers in a high-risk population. MATERIALS AND METHODS: Posteroanterior and lateral radiographs and low-dose spiral CT scans were obtained twice a year from September 1993 to April 1995 in 1,369 individuals (a total of 3,457 examinations) who were at high risk for lung cancer. Low-dose spiral CT parameters were 120 kvP, 50 mA, 10-mm collimation, and 2:1 pitch. RESULTS: Peripheral lung cancer was detected in 15 of 3,457 examinations (0.3%). Among the 15 cases, the results of chest radiography were negative in 11 (73%), and the tumors were detected only at low-dose spiral CT. The detection rates of low-dose spiral CT and chest radiography were 0.43% (15 of 3,457 examinations), respectively. Fourteen (93%) of the 15 (exclusion of one pulmonary lung cancer) tumors were stage I. CONCLUSION: Low-dose spiral CT was superior to chest radiography in the screening and detection of peripheral lung cancer in high-risk individuals. Further large-scale studies are warranted, however, to clarify the efficacy and cost-effectiveness of low-dose spiral CT in a randomized, controlled population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reduced Lung-Cancer Mortality with Volume CT Screening in a Randomized Trial
de Koning, H. J., van der Aalst, C. M., de Jong, P. A., Scholten, E. T., Nackaerts, K., Heuvelmans, M. A., Lammers, J.-W. J., Weenink, C., Yousaf-Khan, U., Horeweg, N., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1911793 · Cited by 3,624
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
“[79] Kaneko M, Eguchi K, Ohmatsu H, Kakinuma R, Naruke T, Suemasu K, et al.”
BackgroundBreast Cancer, Version 4.2017, NCCN Clinical Practice Guidelines in Oncology
Gradishar, W. J., Anderson, B. O., Balassanian, R., Blair, S. L., Burstein, H. J., Cyr, A., Elias, A. D., Farrar, W. B., Forero, A., Giordano, S. H., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0012 · Cited by 1,609
Pfister, D. G., Johnson, D. H., Azzoli, C. G., Sause, W., Smith, T. J., Baker Jr, S., Olak, J., Stover, D., Strawn, J. R., Turrisi, A. T., et al. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.09.053 · Cited by 1,413
Mass screening for lung cancer with mobile spiral computed tomography scanner
Sone, S., Takashima, S., Li, F., Yang, Z., Honda, T., Maruyama, Y., Hasegawa, M., Yamanda, T., Kubo, K., Hanamura, K., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)08229-9 · Cited by 931
American Cancer Society lung cancer screening guidelines
Wender, R., Fontham, E. T. H., Barrera, E., Colditz, G. A., Church, T. R., Ettinger, D. S., Etzioni, R., Flowers, C. R., Scott Gazelle, G., Kelsey, D. K., et al. (2013) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21172 · Cited by 723
Machine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Lung Cancer Screening with CT: Mayo Clinic Experience
Swensen, S. J., Jett, J. R., Hartman, T. E., Midthun, D. E., Sloan, J. A., Sykes, A.-M., Aughenbaugh, G. L., & Clemens, M. A. (2003) · Radiology · doi:10.1148/radiol.2263020036 · Cited by 665
CT Screening for Lung Cancer: Five-year Prospective Experience
Swensen, S. J., Jett, J. R., Hartman, T. E., Midthun, D. E., Mandrekar, S. J., Hillman, S. L., Sykes, A.-M., Aughenbaugh, G. L., Bungum, A. O., & Allen, K. L. (2005) · Radiology · doi:10.1148/radiol.2351041662 · Cited by 636
Lung Cancer Screening, Version 3.2018, NCCN Clinical Practice Guidelines in Oncology
Wood, D. E., Kazerooni, E. A., Baum, S. L., Eapen, G. A., Ettinger, D. S., Hou, L., Jackman, D. M., Klippenstein, D., Kumar, R., Lackner, R. P., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0020 · Cited by 611
Patz, E. F., Goodman, P. C., & Bepler, G. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011303432208 · Cited by 599
Growth rate of small lung cancers detected on mass CT screening.
Hasegawa, M., Sone, S., Takashima, S., Li, F., Yang, Z. G., Maruyama, Y., & Watanabe, T. (2000) · The British Journal of Radiology · doi:10.1259/bjr.73.876.11205667 · Cited by 560
Gene-promoter hypermethylation as a biomarker in lung cancer
Belinsky, S. A. (2004) · Nature Reviews Cancer · doi:10.1038/nrc1432 · Cited by 533
Sone, S., Li, F., Yang, Z.-G., Honda, T., Maruyama, Y., Takashima, S., Hasegawa, M., Kawakami, S., Kubo, K., Haniuda, M., et al. (2001) · British Journal of Cancer · doi:10.1054/bjoc.2000.1531 · Cited by 495
van Iersel, C. A., de Koning, H. J., Draisma, G., Mali, W. P. T. M., Scholten, E. T., Nackaerts, K., Prokop, M., Habbema, J. D. F., Oudkerk, M., & van Klaveren, R. J. (2007) · International Journal of Cancer · doi:10.1002/ijc.22134 · Cited by 494
Adams, S. J., Stone, E., Baldwin, D. R., Vliegenthart, R., Lee, P., & Fintelmann, F. J. (2023) · The Lancet · doi:10.1016/s0140-6736(22)01694-4 · Cited by 467
Lung Cancer Incidence and Mortality with Extended Follow-up in the National Lung Screening Trial
(2019) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2019.05.044 · Cited by 464
Lee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932744 · Cited by 457
Pastorino, U., Bellomi, M., Landoni, C., De Fiori, E., Arnaldi, P., Picchio, M., Pelosi, G., Boyle, P., & Fazio, F. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14188-8 · Cited by 452
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Horeweg, N., Scholten, E. T., de Jong, P. A., van der Aalst, C. M., Weenink, C., Lammers, J.-W. J., Nackaerts, K., Vliegenthart, R., ten Haaf, K., Yousaf-Khan, U. A., et al. (2014) · The Lancet Oncology · doi:10.1016/s1470-2045(14)70387-0 · Cited by 384
Lung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
Armato III, S. G., McLennan, G., McNitt-Gray, M. F., Meyer, C. R., Yankelevitz, D., Aberle, D. R., Henschke, C. I., Hoffman, E. A., Kazerooni, E. A., MacMahon, H., et al. (2004) · Radiology · doi:10.1148/radiol.2323032035 · Cited by 380
Mulkens, T. H., Bellinck, P., Baeyaert, M., Ghysen, D., Van Dijck, X., Mussen, E., Venstermans, C., & Termote, J.-L. (2005) · Radiology · doi:10.1148/radiol.2363041220 · Cited by 354
Nomori, H., Watanabe, K., Ohtsuka, T., Naruke, T., Suemasu, K., & Uno, K. (2004) · Lung Cancer · doi:10.1016/j.lungcan.2004.01.009 · Cited by 344
Self-citationIncidental Extracolonic Findings at CT Colonography
Hara, A. K., Johnson, C. D., MacCarty, R. L., & Welch, T. J. (2000) · Radiology · doi:10.1148/radiology.215.2.r00ap33353 · Cited by 335
Emerging molecular biomarkers—blood-based strategies to detect and monitor cancer
Hanash, S. M., Baik, C. S., & Kallioniemi, O. (2011) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2010.220 · Cited by 328
Mahadevia, P. J., Fleisher, L. A., Frick, K. D., Eng, J., Goodman, S. N., & Powe, N. R. (2003) · JAMA · doi:10.1001/jama.289.3.313 · Cited by 319
Lung Cancer Screening Using Low-Dose Spiral CT
Nawa, T., Nakagawa, T., Kusano, S., Kawasaki, Y., Sugawara, Y., & Nakata, H. (2002) · Chest · doi:10.1378/chest.122.1.15 · Cited by 315
Miss Rate of Lung Cancer on the Chest Radiograph in Clinical Practice
Quekel, L. G. B. A., Kessels, A. G. H., Goei, R., & van Engelshoven, J. M. A. (1999) · Chest · doi:10.1378/chest.115.3.720 · Cited by 311
Gurcan, M. N., Sahiner, B., Petrick, N., Chan, H., Kazerooni, E. A., Cascade, P. N., & Hadjiiski, L. (2002) · Medical Physics · doi:10.1118/1.1515762 · Cited by 309
Photodynamic Therapy (PDT) for Lung Cancers
Usuda, J., Kato, H., Okunaka, T., Furukawa, K., Tsutsui, H., Yamada, K., Suga, Y., Honda, H., Nagatsuka, Y., Ohira, T., et al. (2006) · Journal of Thoracic Oncology · doi:10.1016/s1556-0864(15)31616-6 · Cited by 294
Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
Wormanns, D., Kohl, G., Klotz, E., Marheine, A., Beyer, F., Heindel, W., & Diederich, S. (2004) · European Radiology · doi:10.1007/s00330-003-2132-0 · Cited by 289
Bach, P. B., Kelley, M. J., Tate, R. C., & McCrory, D. C. (2003) · Chest · doi:10.1378/chest.123.1_suppl.72s · Cited by 281
Armato, S. G., Li, F., Giger, M. L., MacMahon, H., Sone, S., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2253011376 · Cited by 280
Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Natural History of Pulmonary Subsolid Nodules: A Prospective Multicenter Study
Kakinuma, R., Noguchi, M., Ashizawa, K., Kuriyama, K., Maeshima, A. M., Koizumi, N., Kondo, T., Matsuguma, H., Nitta, N., Ohmatsu, H., et al. (2016) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2016.04.006 · Cited by 277
Self-citationAwai, K., Murao, K., Ozawa, A., Komi, M., Hayakawa, H., Hori, S., & Nishimura, Y. (2004) · Radiology · doi:10.1148/radiol.2302030049 · Cited by 272
Blanchon, T., Bréchot, J.-M., Grenier, P. A., Ferretti, G. R., Lemarié, E., Milleron, B., Chagué, D., Laurent, F., Martinet, Y., Beigelman-Aubry, C., et al. (2007) · Lung Cancer · doi:10.1016/j.lungcan.2007.05.009 · Cited by 271
Suzuki, K., Armato, S. G., Li, F., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1580485 · Cited by 262
Rubin, G. D., Lyo, J. K., Paik, D. S., Sherbondy, A. J., Chow, L. C., Leung, A. N., Mindelzun, R., Schraedley-Desmond, P. K., Zinck, S. E., Naidich, D. P., et al. (2005) · Radiology · doi:10.1148/radiol.2341040589 · Cited by 259
Automated detection of lung nodules in CT scans: Preliminary results
Armato, S. G., Giger, M. L., & MacMahon, H. (2001) · Medical Physics · doi:10.1118/1.1387272 · Cited by 250
NELSON lung cancer screening study
Ru Zhao, Y., Xie, X., de Koning, H. J., Mali, W. P., Vliegenthart, R., & Oudkerk, M. (2011) · Cancer Imaging · doi:10.1102/1470-7330.2011.9020 · Cited by 249
“Observational studies in high-risk populations have shown that spiral computed tomography (CT) screening detects more lung cancers than chest radiography screening([3,4]), with 55 85% of CT-detected lung cancers being at a surgically removable stage (stage I).”
BackgroundClinical validation of an autoantibody test for lung cancer
Boyle, P., Chapman, C. J., Holdenrieder, S., Murray, A., Robertson, C., Wood, W. C., Maddison, P., Healey, G., Fairley, G. H., Barnes, A. C., et al. (2011) · Annals of Oncology · doi:10.1093/annonc/mdq361 · Cited by 240
“At present, there is nothing to offer for early diagnosis, although ongoing clinical trials are investigating the use of spiral computed tomography (CT) in ‘at-risk’ individuals [3–12].”
BackgroundManser, R., Lethaby, A., Irving, L. B., Stone, C., Byrnes, G., Abramson, M. J., & Campbell, D. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001991.pub3 · Cited by 233
Field, J. K., Vulkan, D., Davies, M. P. A., Baldwin, D. R., Brain, K. E., Devaraj, A., Eisen, T., Gosney, J., Green, B. A., Holemans, J. A., et al. (2021) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2021.100179 · Cited by 230
Wilson, D. O., Weissfeld, J. L., Fuhrman, C. R., Fisher, S. N., Balogh, P., Landreneau, R. J., Luketich, J. D., & Siegfried, J. M. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200802-336oc · Cited by 229
“Between January 2002 and April 2005, the PLuSS used advertisements and mass mailings to recruit volunteers with the following characteristics: (1) age 50 to 79 years; (2) no personal lung cancer history; (3) nonparticipation in concurrent lung cancer screening studies; (4) no chest computed tomography (CT) within 12 m…”
MethodWood, D. E., Eapen, G. A., Ettinger, D. S., Hou, L., Jackman, D., Kazerooni, E., Klippenstein, D., Lackner, R. P., Leard, L., Leung, A. N. C., et al. (2012) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2012.0022 · Cited by 227
Suzuki, K., Li, F., Sone, S., & Doi, K. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852048 · Cited by 219
“In a screening program in Japan, only 83 (10”
BackgroundInfluentialComputer-Aided Diagnosis and Artificial Intelligence in Clinical Imaging
Shiraishi, J., Li, Q., Appelbaum, D., & Doi, K. (2011) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2011.06.004 · Cited by 206
Managing the Small Pulmonary Nodule Discovered by CT
Libby, D. M., Smith, J. P., Altorki, N. K., Pasmantier, M. W., Yankelevitz, D., & Henschke, C. I. (2004) · Chest · doi:10.1378/chest.125.4.1522 · Cited by 202
Shah, P. K., Austin, J. H. M., White, C. S., Patel, P., Haramati, L. B., Pearson, G. D. N., Shiau, M. C., & Berkmen, Y. M. (2003) · Radiology · doi:10.1148/radiol.2261011924 · Cited by 198
Computed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Schaefer, J. F., Vollmar, J., Schick, F., Vonthein, R., Seemann, M. D., Aebert, H., Dierkesmann, R., Friedel, G., & Claussen, C. D. (2004) · Radiology · doi:10.1148/radiol.2322030515 · Cited by 179
CT Findings and Progression of Small Peripheral Lung Neoplasms Having a Replacement Growth Pattern
Takashima, S., Maruyama, Y., Hasegawa, M., Yamanda, T., Honda, T., Kadoya, M., & Sone, S. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.3.1800817 · Cited by 174
Perifissural Nodules Seen at CT Screening for Lung Cancer
Ahn, M. I., Gleeson, T. G., Chan, I. H., McWilliams, A. M., MacDonald, S. L., Lam, S., Atkar-Khattra, S., & Mayo, J. R. (2010) · Radiology · doi:10.1148/radiol.09090031 · Cited by 169
Survival following lobectomy vs limited resection for stage I lung cancer: a meta-analysis
Nakamura, H., Kawasaki, N., Taguchi, M., & Kabasawa, K. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602414 · Cited by 167
“One example would be a small, slowly growing, localised bronchioloalveolar carcinoma showing only ground-glass opacity (GGO) on computed tomography (Kaneko et al, 1996; Sone et al, 1998).”
BackgroundTerasaki, H., Niki, T., Matsuno, Y., Yamada, T., Maeshima, A., Asamura, H., Hayabuchi, N., & Hirohashi, S. (2003) · The American Journal of Surgical Pathology · doi:10.1097/00000478-200307000-00009 · Cited by 167
Prävention, Diagnostik, Therapie und Nachsorge des Lungenkarzinoms
Goeckenjan, G., Sitter, H., Thomas, M., Branscheid, D., Flentje, M., Griesinger, F., Niederle, N., Stuschke, M., Blum, T., Deppermann, K.-M., et al. (2010) · Pneumologie · doi:10.1055/s-0029-1243837 · Cited by 165
Kakinuma, R., Ohmatsu, H., Kaneko, M., Kusumoto, M., Yoshida, J., Nagai, K., Nishiwaki, Y., Kobayashi, T., Tsuchiya, R., Nishiyama, H., et al. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200401000-00003 · Cited by 163
“the Anti–Lung Cancer Association (ALCA), a for-profit organization for lung cancer screening.(20,21) Each screening consisted of a low-dose helical CT examination, chest radiography, and cytologic sputum studies.”
BackgroundSelf-citationHuang, Y.-L., Wu, F.-Z., Wang, Y.-C., Ju, Y.-J., Mar, G.-Y., Chuo, C.-C., Lin, H.-S., & Wu, M.-T. (2013) · European Radiology · doi:10.1007/s00330-012-2726-5 · Cited by 43
Metadata
- Authors
- Kaneko, M., Eguchi, K., Ohmatsu, H., Kakinuma, R., Naruke, T., Suemasu, K., & Moriyama, N.
- Venue
- Radiology
- Published
- 1996-12
- Volume
- 201
- Issue
- 3
- Pages
- 798-802
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2143045812
- Cited by
- 831
- References
- 0
- FWCI
- 15.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.