Mesenteric circulation: three-dimensional MR angiography with a gadolinium-enhanced multiecho gradient-echo technique.
The DOI matches its Crossref record.
Abstract
To evaluate the mesenteric circulation with magnetic resonance (MR) angiography, the authors examined 16 individuals (12 patients, four volunteers) with a gadolinium-enhanced, breath-hold, fat-saturated, multiecho, three-dimensional, gradient-echo sequence. Twenty examinations were performed. Grades of 3 or 4 (on a five-point scale [4 = best seen, 0 = not seen]) were applicable to 17 (85%) of 20 MR angiograms obtained in superior mesenteric artery trunks, 15 (75%) in celiac arteries, five (25%) in inferior mesenteric arteries; 15 (75%) of first-order branching, 12 (60%) of second-order branching, and 10 (50%) of third-order branching; 17 (85%) in superior mesenteric veins; and 17 (85%) in portal veins. MR angiography with this technique depicted the mesenteric arterial and venous circulation and the portal vein with excellent resolution in a short time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se34876 · Cited by 538
Mesenteric Venous Thrombosis: Diagnosis and Noninvasive Imaging
Bradbury, M. S., Kavanagh, P. V., Bechtold, R. E., Chen, M. Y., Ott, D. J., Regan, J. D., & Weber, T. M. (2002) · RadioGraphics · doi:10.1148/radiographics.22.3.g02ma10527 · Cited by 210
Hagspiel, K. D., Flors, L., Hanley, M., & Norton, P. T. (2015) · Techniques in Vascular and Interventional Radiology · doi:10.1053/j.tvir.2014.12.002 · Cited by 88
“Several groups have investigated the influence of caloric stimulation on image quality with conflicting results and thus we do not use this technique.(27,28) The use of anticholinergic agents has not been proven to affect positively on image quality.”
Carlos, R. C., Stanley, J. C., Stafford-Johnson, D., & Prince, M. R. (2001) · Academic Radiology · doi:10.1016/s1076-6332(03)80767-5 · Cited by 55
Vascular imaging of the mesenteric vasculature
van Dijk, L. J. D., van Petersen, A. S., & Moelker, A. (2017) · Best Practice & Research Clinical Gastroenterology · doi:10.1016/j.bpg.2016.12.001 · Cited by 30
Metadata
- Authors
- Shirkhoda, A., Konez, O., Shetty, A. N., Bis, K. G., Ellwood, R. A., & Kirsch, M. J.
- Venue
- Radiology
- Published
- 1997-01
- Volume
- 202
- Issue
- 1
- Pages
- 257-261
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2110968469
- Cited by
- 75
- References
- 0
- FWCI
- 10.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mesenteric circulation: three-dimensional MR angiography with a gadolinium-enhanced multiecho gradient-echo technique. https://app.cochat.ai/papers/10.1148/radiology.202.1.8988220
- The paper
- Shirkhoda, A., Konez, O., Shetty, A. N., Bis, K. G., Ellwood, R. A., & Kirsch, M. J. (1997). Mesenteric circulation: three-dimensional MR angiography with a gadolinium-enhanced multiecho gradient-echo technique. Radiology. https://doi.org/10.1148/radiology.202.1.8988220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.