Breast MR imaging: interpretation model.
The DOI matches its Crossref record.
Abstract
PURPOSE: To develop an interpretation model based on architectural features of suspicious breast findings on magnetic resonance (MR) images. MATERIALS AND METHODS: One hundred ninety-two patients with mammographically visible or palpable findings underwent T1- and fat-saturated T2-weighted spin-echo and contrast agent-enhanced fat-saturated gradient-echo MR imaging. Patients underwent subsequent excisional biopsy for histopathologic confirmation. An interpretation model was constructed by using 98 cases and was tested prospectively and expanded by using 94 different cases. Sensitivity, specificity, predictive values, and receiver operating characteristic curves were computed for all models. RESULTS: Individual features with high predictive values were MR visibility, enhancement degree and pattern, focal mass border characteristics, and focal mass internal septations. Feature combinations with high negative predictive values for malignancy were absence of an MR-visible abnormality, focal masses with smooth borders, lobulated or irregular masses with nonenhancing internal septations, and focal masses with no (or minimal) enhancement. The validated- and revised-model performance characteristics were, respectively, as follows: sensitivity, 100% and 96%; specificity, 69% and 79%; positive predictive value, 75% and 76%; negative predictive value, 100% and 97%; and overall accuracy, 83% and 86%. CONCLUSION: An interpretation model that incorporates breast MR architectural features can achieve high sensitivity and improve specificity for diagnosing breast cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Kuhl, C. K., Mielcareck, P., Klaschik, S., Leutner, C., Wardelmann, E., Gieseke, J., & Schild, H. H. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap38101 · Cited by 1,277
MR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer
Orel, S. G., & Schnall, M. D. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl3113 · Cited by 759
Self-citationUltrasound Imaging Technologies for Breast Cancer Detection and Management: A Review
Guo, R., Lu, G., Qin, B., & Fei, B. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.09.012 · Cited by 542
Diagnostic Architectural and Dynamic Features at Breast MR Imaging: Multicenter Study
Schnall, M. D., Blume, J., Bluemke, D. A., DeAngelis, G. A., DeBruhl, N., Harms, S., Heywang-Köbrunner, S. H., Hylton, N., Kuhl, C. K., Pisano, E. D., et al. (2006) · Radiology · doi:10.1148/radiol.2381042117 · Cited by 514
Self-citationRohlfing, T., Maurer, C. R., Bluemke, D. A., & Jacobs, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.814791 · Cited by 445
Dual-Energy Contrast-enhanced Digital Subtraction Mammography: Feasibility
Lewin, J. M., Isaacs, P. K., Vance, V., & Larke, F. J. (2003) · Radiology · doi:10.1148/radiol.2291021276 · Cited by 389
MR Elastography of Breast Cancer: Preliminary Results
McKnight, A. L., Kugel, J. L., Rossman, P. J., Manduca, A., Hartmann, L. C., & Ehman, R. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781411 · Cited by 381
Solin, L. J., Orel, S. G., Hwang, W.-T., Harris, E. E., & Schnall, M. D. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.5448 · Cited by 346
Self-citationBreast Lesions Detected on MR Imaging: Features and Positive Predictive Value
Liberman, L., Morris, E. A., Lee, M. J.-Y., Kaplan, J. B., LaTrenta, L. R., Menell, J. H., Abramson, A. F., Dashnaw, S. M., Ballon, D. J., & Dershaw, D. D. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.1.1790171 · Cited by 321
Plewes, D. B., Bishop, J., Samani, A., & Sciarretta, J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/314 · Cited by 318
Magnetic Resonance Imaging and Mammography in Women With a Hereditary Risk of Breast Cancer
Stoutjesdijk, M. J., Boetes, C., Jager, G. J., Beex, L., Bult, P., Hendriks, J. H. C. L., Laheij, R. J. F., Massuger, L., van Die, L. E., Wobbes, T., et al. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.14.1095 · Cited by 289
Re: Magnetic Resonance Imaging and Mammography in Women With a Hereditary Risk of Breast Cancer
Goffin, J., Chappuis, P. O., Wong, N., & Foulkes, W. D. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.22.1754 · Cited by 284
In vivo diffusion‐weighted MRI of the breast: Potential for lesion characterization
Sinha, S., Lucas‐Quesada, F. A., Sinha, U., DeBruhl, N., & Bassett, L. W. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10116 · Cited by 268
Kuhl, C. K. (2000) · European Radiology · doi:10.1007/s003300050006 · Cited by 221
“In terms of configuration, fibroadenomas present as masses, almost always with roundish, ovoid, or lobulated shape, and with smooth margins [3, 38, 41 , 74].”
BackgroundKinkel, K., Helbich, T. H., Esserman, L. J., Barclay, J., Schwerin, E. H., Sickles, E. A., & Hylton, N. M. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.1.1750035 · Cited by 219
“The interpretation model presented here is not inconsistent with that of Nunes et al. [ 7 , 10].”
MethodResultEl Khouli, R. H., Macura, K. J., Barker, P. B., Habba, M. R., Jacobs, M. A., & Bluemke, D. A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21947 · Cited by 213
Chen, W., Giger, M. L., Bick, U., & Newstead, G. M. (2006) · Medical Physics · doi:10.1118/1.2210568 · Cited by 211
Update of Breast MR Imaging Architectural Interpretation Model
Nunes, L. W., Schnall, M. D., & Orel, S. G. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma44484 · Cited by 208
Self-citationComputerized analysis of breast lesions in three dimensions using dynamic magnetic‐resonance imaging
Gilhuijs, K. G. A., Giger, M. L., & Bick, U. (1998) · Medical Physics · doi:10.1118/1.598345 · Cited by 195
Computerized interpretation of breast MRI: Investigation of enhancement‐variance dynamics
Chen, W., Giger, M. L., Lan, L., & Bick, U. (2004) · Medical Physics · doi:10.1118/1.1695652 · Cited by 186
Yabuuchi, H., Matsuo, Y., Okafuji, T., Kamitani, T., Soeda, H., Setoguchi, T., Sakai, S., Hatakenaka, M., Kubo, M., Sadanaga, N., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21570 · Cited by 181
Metadata
- Authors
- Nunes, L. W., Schnall, M. D., Orel, S. G., Hochman, M. G., Langlotz, C. P., Reynolds, C. A., & Torosian, M. H.
- Venue
- Radiology
- Published
- 1997-03
- Volume
- 202
- Issue
- 3
- Pages
- 833-841
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2032515605
- Cited by
- 252
- References
- 0
- FWCI
- 16.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.