Hepatic lesions: detection with ferumoxide-enhanced T1-weighted MR imaging.
The DOI matches its Crossref record.
Abstract
PURPOSE: To compare the use of ferumoxide-enhanced T1-weighted gradient-echo (GRE) MR imaging with that of spiral computed tomography during arterial portography (CTAP) and T2-weighted Turbo spin-echo (SE) MR imaging in detection of lesions and of segmental involvement in patients with liver metastases. MATERIALS AND METHODS: Twenty-two candidates for metastasectomy of the liver underwent spiral CTAP, ferumoxide-enhanced GRE MR imaging, and T2-weighted Turbo SE MR imaging. A total of 176 liver segments were evaluated (57 with and 119 without metastases). The reference standard was laparoscopic sonographic findings. Diagnostic performance of the imaging modalities was assessed for lesion detection and determination of segmental involvement. RESULTS: The sensitivity for lesion detection with spiral CTAP, ferumoxide-enhanced MR imaging, and T2-weighted MR imaging was 0.96, 0.83, and 0.71, respectively; for segmental analysis, the sensitivity was 0.96, 0.84, and 0.75, respectively, and the specificity was 0.80, 0.99, and 0.92, respectively. All comparisons between sensitivities and specificities were statistically significant (P < .05). CONCLUSION: Ferumoxide-enhanced T1-weighted GRE MR imaging is superior to T2-weighted SE MR imaging for preoperative detection of lesions and segmental involvement in patients with liver metastases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reimer, P., & Balzer, T. (2003) · European Radiology · doi:10.1007/s00330-002-1721-7 · Cited by 614
Superparamagnetic iron oxide based MRI contrast agents: Current status of clinical application.
Wáng, Y. X. J. (2011) · PubMed · doi:10.3978/j.issn.2223-4292.2011.08.03 · Cited by 613
Colorectal Liver Metastases: CT, MR Imaging, and PET for Diagnosis—Meta-analysis
Bipat, S., van Leeuwen, M. S., Comans, E. F. I., Pijl, M. E. J., Bossuyt, P. M. M., Zwinderman, A. H., & Stoker, J. (2005) · Radiology · doi:10.1148/radiol.2371042060 · Cited by 544
MAGNETIC NANOPARTICLE HYPERTHERMIA IN CANCER TREATMENT
GIUSTINI, A. J., PETRYK, A. A., CASSIM, S. M., TATE, J. A., BAKER, I., & HOOPES, P. J. (2010) · Nano LIFE · doi:10.1142/s1793984410000067 · Cited by 390
Contrast Agents for MR Imaging of the Liver
Semelka, R. C., & Helmberger, T. K. G. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja2427 · Cited by 337
Metadata
- Authors
- Oudkerk, M., van den Heuvel, A. G., Wielopolski, P. A., Schmitz, P. I., Borel Rinkes, I. H., & Wiggers, T.
- Venue
- Radiology
- Published
- 1997-05
- Volume
- 203
- Issue
- 2
- Pages
- 449-456
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2145289818
- Cited by
- 113
- References
- 0
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hepatic lesions: detection with ferumoxide-enhanced T1-weighted MR imaging. https://app.cochat.ai/papers/10.1148/radiology.203.2.9114103
- The paper
- Oudkerk, M., van den Heuvel, A. G., Wielopolski, P. A., Schmitz, P. I., Borel Rinkes, I. H., & Wiggers, T. (1997). Hepatic lesions: detection with ferumoxide-enhanced T1-weighted MR imaging. Radiology. https://doi.org/10.1148/radiology.203.2.9114103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.