The DOI matches its Crossref record.
Focal liver masses: characterization with diffusion-weighted echo-planar MR imaging.
Abstract
PURPOSE: To evaluate diffusion-weighted echo-planar magnetic resonance (MR) imaging for improving the specificity of characterization of liver tumors. MATERIALS AND METHODS: Diffusion-weighted echo-planar imaging was performed with a 1.5-T whole-body imager with use of a body phased-array coil in 51 patients with 59 hepatic masses (41 malignant tumors, nine hemangiomas, and nine cysts). Apparent diffusion coefficient (ADC) values were obtained with two motion-probing gradients (b = 30 and 1,200 sec/mm2) during each of the breath-hold periods, and an ADC map was constructed. The T2 was derived from spin-echo echo-planar images with echo times of 47 and 99 msec. RESULTS: The ADC value of malignant masses (1.04 x 10(-3) mm2/sec) was significantly lower (P < .01) than that of benign masses (hemangiomas [1.95 x 10(-3) mm2/sec] and cysts [3.05 x 10(-3) mm2/sec]), although the T2s showed considerable overlap. A small amount of overlap in ADC values occurred among malignant tumors, hemangiomas, and cysts. ADC values of two cystic masses from ovarian carcinomas were within the range of those of hemangiomas. CONCLUSION: These preliminary results indicate that diffusion-weighted MR imaging can be useful in characterizing focal liver masses. With the exception of cystic metastatic tumors, the technique may be especially useful in tumors that appear markedly hyperintense on T2-weighted images due to a long T2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Patel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
Diffusion-weighted single-shot echoplanar MR imaging for liver disease.
Kim, T., Murakami, T., Takahashi, S., Hori, M., Tsuda, K., & Nakamura, H. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.2.10430143 · Cited by 349
Nonalcoholic fatty liver disease
Erickson, S. K. (2009) · Journal of Lipid Research · doi:10.1194/jlr.r800089-jlr200 · Cited by 194
Metadata
- Authors
- Namimoto, T., Yamashita, Y., Sumi, S., Tang, Y., & Takahashi, M.
- Venue
- Radiology
- Published
- 1997-09
- Volume
- 204
- Issue
- 3
- Pages
- 739-744
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2099317817
- Cited by
- 349
- References
- 0
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Focal liver masses: characterization with diffusion-weighted echo-planar MR imaging. https://app.cochat.ai/papers/10.1148/radiology.204.3.9280252
- The paper
- Namimoto, T., Yamashita, Y., Sumi, S., Tang, Y., & Takahashi, M. (1997). Focal liver masses: characterization with diffusion-weighted echo-planar MR imaging. Radiology. https://doi.org/10.1148/radiology.204.3.9280252
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.