The DOI matches its Crossref record.
Intracranial Aneurysms: Detection with Three-dimensional CT Angiography with Volume Rendering—Comparison with Conventional Angiographic and Surgical Findings
Abstract
PURPOSE: To assess the diagnostic accuracy of three-dimensional (3D) computed tomographic (CT) angiography for intracranial aneurysms. MATERIALS AND METHODS: The 3D CT angiograms obtained in 49 patients with or without intracranial aneurysms were evaluated by four blinded observers. Results were compared with findings at conventional angiography or surgery. A volume-rendering method was used, and 13 images obtained in different directions were reviewed in each study. The diameter of aneurysms was divided into four sizes: large, greater than 13 mm; medium, 5-12 mm; small, 3-4 mm; and very small, less than 3 mm. Results were also evaluated by means of receiver operating characteristic analysis. RESULTS: At conventional angiography, 47 aneurysms, including 14 less than 3 mm, were depicted in 35 patients. The mean sensitivity of CT angiography for very small aneurysms was 64%; small, 83%; medium, 95%; and large, 100%. Some very small aneurysms that were not depicted at conventional angiography were depicted at CT angiography, and one was proved at surgery. CONCLUSION: CT angiography has good sensitivity for depiction of intracranial aneurysms 3 mm or larger and relatively good sensitivity for aneurysms less than 3 mm. CT angiography may be a noninvasive technique for detection of asymptomatic unruptured or ruptured aneurysms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Connolly, E. S., Rabinstein, A. A., Carhuapoma, J. R., Derdeyn, C. P., Dion, J., Higashida, R. T., Hoh, B. L., Kirkness, C. J., Naidech, A. M., Ogilvy, C. S., et al. (2012) · Stroke · doi:10.1161/str.0b013e3182587839 · Cited by 3,512
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Bederson, J. B., Connolly, E. S., Batjer, H. H., Dacey, R. G., Dion, J. E., Diringer, M. N., Duldner, J. E., Harbaugh, R. E., Patel, A. B., & Rosenwasser, R. H. (2009) · Stroke · doi:10.1161/strokeaha.108.191395 · Cited by 1,189
Guglielmi Detachable Coil embolization of cerebral aneurysms: 11 years' experience
Murayama, Y., Nien, Y. L., Duckwiler, G., Gobin, Y. P., Jahan, R., Frazee, J., Martin, N., & Viñuela, F. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.5.0959 · Cited by 810
CT Angiography “Spot Sign” Predicts Hematoma Expansion in Acute Intracerebral Hemorrhage
Wada, R., Aviv, R. I., Fox, A. J., Sahlas, D. J., Gladstone, D. J., Tomlinson, G., & Symons, S. P. (2007) · Stroke · doi:10.1161/01.str.0000259633.59404.f3 · Cited by 691
Metadata
- Authors
- Korogi, Y., Takahashi, M., Katada, K., Ogura, Y., Hasuo, K., Ochi, M., Utsunomiya, H., Abe, T., & Imakita, S.
- Venue
- Radiology
- Published
- 1999-05
- Volume
- 211
- Issue
- 2
- Pages
- 497-506
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2133556260
- Cited by
- 187
- References
- 0
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracranial Aneurysms: Detection with Three-dimensional CT Angiography with Volume Rendering—Comparison with Conventional Angiographic and Surgical Findings. https://app.cochat.ai/papers/10.1148/radiology.211.2.r99ma02497
- The paper
- Korogi, Y., Takahashi, M., Katada, K., Ogura, Y., Hasuo, K., Ochi, M., Utsunomiya, H., Abe, T., & Imakita, S. (1999). Intracranial Aneurysms: Detection with Three-dimensional CT Angiography with Volume Rendering—Comparison with Conventional Angiographic and Surgical Findings. Radiology. https://doi.org/10.1148/radiology.211.2.r99ma02497
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.