Intracranial Aneurysms: Detection with Three-dimensional CT Angiography with Volume Rendering—Comparison with Conventional Angiographic and Surgical Findings
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
PURPOSE: To assess the diagnostic accuracy of three-dimensional (3D) computed tomographic (CT) angiography for intracranial aneurysms. MATERIALS AND METHODS: The 3D CT angiograms obtained in 49 patients with or without intracranial aneurysms were evaluated by four blinded observers. Results were compared with findings at conventional angiography or surgery. A volume-rendering method was used, and 13 images obtained in different directions were reviewed in each study. The diameter of aneurysms was divided into four sizes: large, greater than 13 mm; medium, 5-12 mm; small, 3-4 mm; and very small, less than 3 mm. Results were also evaluated by means of receiver operating characteristic analysis. RESULTS: At conventional angiography, 47 aneurysms, including 14 less than 3 mm, were depicted in 35 patients. The mean sensitivity of CT angiography for very small aneurysms was 64%; small, 83%; medium, 95%; and large, 100%. Some very small aneurysms that were not depicted at conventional angiography were depicted at CT angiography, and one was proved at surgery. CONCLUSION: CT angiography has good sensitivity for depiction of intracranial aneurysms 3 mm or larger and relatively good sensitivity for aneurysms less than 3 mm. CT angiography may be a noninvasive technique for detection of asymptomatic unruptured or ruptured aneurysms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Statistical Methods for Rates and Proportions, 2nd ed
GROVE, W. A. (1981) · American Journal of Psychiatry · doi:10.1176/ajp.138.12.1644-a · Cited by 3,748
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC Studies
METZ, C. E. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00012 · Cited by 859
CT angiography in the evaluation of acute stroke.
Shrier, D. A., Tanaka, H., Numaguchi, Y., Konno, S., Patel, U., & Shibata, D. K. (1997) · PubMed · Cited by 149
Cerebral aneurysms: evaluation with three-dimensional CT angiography.
Ogawa, T., Okudera, T., Noguchi, K., Sasaki, N., Inugami, A., Uemura, K., & Yasui, N. (1996) · PubMed Central · Cited by 135
CT angiography with volume rendering: advantages and applications in splanchnic vascular imaging.
Johnson, P. T., Heath, D. G., Kuszyk, B. S., & Fishman, E. K. (1996) · Radiology · doi:10.1148/radiology.200.2.8685358 · Cited by 128
Korogi, Y., Takahashi, M., Mabuchi, N., Nakagawa, T., Fujiwara, S., Horikawa, Y., Hiroshi, M. I. K. I., O’uchi, T., Shiga, H., Shiokawa, Y., et al. (1996) · Radiology · doi:10.1148/radiology.199.1.8633146 · Cited by 74
Self-citation
Cited by
Connolly, E. S., Rabinstein, A. A., Carhuapoma, J. R., Derdeyn, C. P., Dion, J., Higashida, R. T., Hoh, B. L., Kirkness, C. J., Naidech, A. M., Ogilvy, C. S., et al. (2012) · Stroke · doi:10.1161/str.0b013e3182587839 · Cited by 3,512
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
“[126] Korogi Y, Takahashi M, Katada K, Ogura Y, Hasuo K, Ochi M, et al.”
BackgroundBederson, J. B., Connolly, E. S., Batjer, H. H., Dacey, R. G., Dion, J. E., Diringer, M. N., Duldner, J. E., Harbaugh, R. E., Patel, A. B., & Rosenwasser, R. H. (2009) · Stroke · doi:10.1161/strokeaha.108.191395 · Cited by 1,189
Guglielmi Detachable Coil embolization of cerebral aneurysms: 11 years' experience
Murayama, Y., Nien, Y. L., Duckwiler, G., Gobin, Y. P., Jahan, R., Frazee, J., Martin, N., & Viñuela, F. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.5.0959 · Cited by 810
CT Angiography “Spot Sign” Predicts Hematoma Expansion in Acute Intracerebral Hemorrhage
Wada, R., Aviv, R. I., Fox, A. J., Sahlas, D. J., Gladstone, D. J., Tomlinson, G., & Symons, S. P. (2007) · Stroke · doi:10.1161/01.str.0000259633.59404.f3 · Cited by 691
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Anxionnat, R., Bracard, S., Ducrocq, X., Trousset, Y., Launay, L., Kerrien, E., Braun, M., Vaillant, R., Scomazzoni, F., Lebedinsky, A., et al. (2001) · Radiology · doi:10.1148/radiology.218.3.r01mr09799 · Cited by 247
Epidemiology of Aneurysmal Subarachnoid Hemorrhage
Zacharia, B. E., Hickman, Z. L., Grobelny, B. T., DeRosa, P., Kotchetkov, I., Ducruet, A. F., & Connolly, E. S. (2010) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2009.10.002 · Cited by 245
McKinney, A. M., Palmer, C. S., Truwit, C. L., Karagulle, A., & Teksam, M. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0848 · Cited by 234
“The sensitivities in initial studies of SSCTA varied widely, ranging from 67% to 100%, with significant difficulty noted in detecting aneurysms less than 4 mm.(17-22) When 4MSCTA emerged, results among several studies were also variable but largely demonstrated that the sensitivity was more than 90% in aneurysms at or…”
BackgroundDetection of Intracranial Aneurysms: Multi–Detector Row CT Angiography Compared with DSA
Jayaraman, M. V., Mayo-Smith, W. W., Tung, G. A., Haas, R. A., Rogg, J. M., Mehta, N. R., & Doberstein, C. E. (2004) · Radiology · doi:10.1148/radiol.2302021465 · Cited by 215
Computed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Metadata
- Authors
- Korogi, Y., Takahashi, M., Katada, K., Ogura, Y., Hasuo, K., Ochi, M., Utsunomiya, H., Abe, T., & Imakita, S.
- Venue
- Radiology
- Published
- 1999-05
- Volume
- 211
- Issue
- 2
- Pages
- 497-506
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2133556260
- Cited by
- 187
- References
- 8
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.