Relationship between the Resistive Index and Vascular Compliance and Resistance
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the dependence of the resistive index (RI) on not only vascular resistance but also vascular compliance. MATERIALS AND METHODS: An in vitro model that made use of a pulsatile pump, blood-mimicking fluid, and variable compliance and resistance was used to investigate the relationship between the RI and both vascular compliance and resistance. RESULTS: In the absence of vascular compliance, the RI was independent of vascular resistance. With vascular compliance, the RI was dependent on vascular resistance and increased with increasing resistance. The higher the compliance, the more the RI was affected by resistance. CONCLUSION: The RI is misnamed and should actually be called the "impedance index" because resistance and compliance interact to alter the Doppler arterial waveform. A greater understanding of this relationship may enable future studies that take both resistance and compliance into account to better detect pathologic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Avolio, A. P., Deng, F. Q., Li, W. Q., Luo, Y. F., Huang, Z. D., Xing, L. F., & O'Rourke, M. F. (1985) · Circulation · doi:10.1161/01.cir.71.2.202 · Cited by 839
The Elastic Properties of the Arterial Wall
Roy, C. S. (1881) · The Journal of Physiology · doi:10.1113/jphysiol.1881.sp000088 · Cited by 343
STUDIES ON THE ELASTIC PROPERTIES OF HUMAN ISOLATED AORTA
Hallock, P., & Benson, I. C. (1937) · Journal of Clinical Investigation · doi:10.1172/jci100886 · Cited by 299
Effect of placental embolization on the umbilical arterial velocity waveform in fetal sheep
Morrow, R. J., Adamson, S. L., Bull, S. B., & Knox Ritchie, J. W. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90783-7 · Cited by 243
Norris, C. S., & Barnes, R. W. (1984) · Journal of Surgical Research · doi:10.1016/0022-4804(84)90092-1 · Cited by 174
Noninvasive evaluation of renal artery stenosis and renovascular resistance
Norris, C. M., Pfeiffer, J. S., Rittgers, S. E., & Barnes, R. W. (1984) · Journal of Vascular Surgery · doi:10.1067/mva.1984.avs0010192 · Cited by 157
Aortic compliance measurements using doppler ultrasound: In vivo biochemical correlates
Lehmann, E. D., Hopkins, K. D., & Gosling, R. G. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90087-5 · Cited by 129
The Hydrodynamics of the Arterial Circulation
McDonald, D. A., & Taylor, M. G. (1959) · Progress in Biophysics and Biophysical Chemistry · doi:10.1016/s0096-4174(18)30167-7 · Cited by 129
Adamson, S. L., Morrow, R. J., Langille, B. L., Bull, S. B., & Ritchie, J. W. K. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90082-n · Cited by 92
Taylor, M. G. (1959) · Physics in Medicine and Biology · doi:10.1088/0031-9155/4/1/308 · Cited by 88
An Approach to an Analysis of the Arterial Pulse Wave II. Fluid Oscillations in an Elastic Pipe
Taylor, M. G. (1957) · Physics in Medicine & Biology · doi:10.1088/0031-9155/1/4/302 · Cited by 79
Arterial Compliance and Blood Pressure
Marchais, S. J., Guérin, A. P., Pannier, B., Delavaud, G., & London, G. M. (1993) · Drugs · doi:10.2165/00003495-199300462-00015 · Cited by 44
Hemodynamic factors affecting uterine artery Doppler waveform pulsatility in sheep.
Saunders, H., Burns, P. N., Needleman, L., Liu, J., Boston, R. C., Wortman, J. A., & Chan, L. (1998) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1998.17.6.357 · Cited by 34
Cited by
Wu, Q., Qiao, Y., Guo, R., Naveed, S., Hirtz, T., Li, X., Fu, Y., Wei, Y., Deng, G., Yang, Y., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c03294 · Cited by 276
Nijst, P., Martens, P., Dupont, M., Tang, W. H. W., & Mullens, W. (2017) · JACC: Heart Failure · doi:10.1016/j.jchf.2017.05.006 · Cited by 159
Ning, R., Li, Y., Du, Z., Li, T., Sun, Q., Lin, L., Xu, Q., Duan, J., & Sun, Z. (2021) · Redox Biology · doi:10.1016/j.redox.2021.102113 · Cited by 96
“with the occurrence of future cardiovascular events, as well as PI and RI are markers of arterial resistance and compliance [38,39].”
Macedo, T. A. A., Chammas, M. C., Jorge, P. T., Souza, L. P., Farage, L., Watanabe, T., Santos, V. A., & Cerri, G. G. (2007) · Acta Radiologica · doi:10.1080/02841850701280791 · Cited by 24
Metadata
- Authors
- Bude, R. O., & Rubin, J. M.
- Venue
- Radiology
- Published
- 1999-05
- Volume
- 211
- Issue
- 2
- Pages
- 411-417
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1982483134
- Cited by
- 356
- References
- 14
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.