The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Dixon-based MRI for assessment of muscle-fat content in phantoms, healthy volunteers and patients with achillodynia: comparison to visual assessment of calf muscle quality
Open accessAbstract
Objectives To quantify the muscle fat-content (MFC) in phantoms, volunteers and patients with achillodynia using two-point Dixon-based magnetic resonance imaging (2pt-MRIDIXON) in comparison to MR spectroscopy (MRS) and visual assessment of MFC.Methods Two-point Dixon-based MRI was used to measure the MFC of 15 phantoms containing 0-100 % fat-content and calf muscles in 30 patients (13 women; 57 ± 15 years) with achillodynia and in 20 volunteers (10 women; 30 ± 14 years) at 1.5 T. The accuracy of 2pt-MRIDIXON in quantification of MFC was assessed in vitro using phantoms and in vivo using MRS as the standard of reference. Fat-fractions derived from 2pt-MRIDIXON (FFDIXON) and MRS (FFMRS) were related to visual assessment of MFC (Goutallier grades 0-4) and Achilles-tendon quality (grade 0-4).Results Excellent linear correlation was demonstrated for FFDIXON with phantoms and with FFMRS in patients (p c = 0.997/0.995; p < 0.001). FFDIXON of the gastrocnemius muscle was significantly higher (p = 0.002) in patients (7.0 % ± 4.7 %) compared with volunteers (3.6 % ± 0.7 %), whereas visual-grading showed no difference between both groups (p > 0.05). FFMRS and FFDIXON were significantly higher in subjects with (>grade 1) structural damage of the Achilles-tendon (p = 0.01).Conclusions Two-point Dixon-based MRI allows for accurate quantification of MFC, outperforming visual assessment of calf muscle fat. Structural damage of the Achilles tendon is associated with a significantly higher MFC.Key points Two-point Dixon-based MRI allows accurate quantification of muscular fat content (MFC). Quantitative analysis outperforms visual analysis in the detection of elevated MFC. Achillodynia results in an increased MFC of the gastrocnemius muscles. Structural damage of the Achilles tendon further increases the MFC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These aberrant changes can lead to reduced muscle mass and strength, both crucial components of sarcopenia.63–65”
From Imaging of Sarcopenia in Type 2 Diabetes Mellitus (2024) · cites this paper as [63]
Citations
Cites
Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan.
GOUTALLIER, D., Postel, J.-M., BERNAGEAU, J., Lavau, L., & Voisin, M. C. (1994) · PubMed · Cited by 2,554
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276 · cited 1×
“This algorithm was shown to provide stable water- and fat-signal separation for dual-echo imaging using phase information to resolve the ambiguity of fat and water signal in chemical-shift imaging [3, 13].”
MethodFatty Muscle Degeneration in Cuff Ruptures: Pre- and Postoperative Evaluation by CT Scan
Goutallier, D., Postel, J.-M., Bernageau, J., Lavau, L., & Voisin, M.-C. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199407000-00014 · Cited by 2,150 · cited 2×
“Several studies have suggested that assessment of MFC may serve as a biomarker for detection of muscular insufficiency and prediction of post-surgical outcome in degenerative musculoskeletal disease [2, 7, 9, 10, 16, 18].”
BackgroundTENDON INJURY AND TENDINOPATHY: HEALING AND REPAIR
SHARMA, P., & MAFFULLI, N. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200501000-00030 · Cited by 1,074 · cited 2×
“Concerning pathophysiology, a series of mechanisms reducing tissue perfusion and mechanical irritation lead to degeneration of the tendon [6].”
BackgroundGladstone, J. N., Bishop, J. Y., Lo, I. K. Y., & Flatow, E. L. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506297539 · Cited by 967 · cited 1×
“Several studies have suggested that assessment of MFC may serve as a biomarker for detection of muscular insufficiency and prediction of post-surgical outcome in degenerative musculoskeletal disease [2, 7, 9, 10, 16, 18].”
BackgroundYu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694 · cited 1×
“show—similar to the ex vivo study—a measurement bias of 2pt-MRIDixon for very small and high FFDIXON, probably due to noise bias [3] and single-peak modelling of fat [28, 29] respectively, resulting in a slope of 0.”
ResultDixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610 · cited 4×
“However, comparable to another study using fat/liver phantoms there was an overestimation of very small fat contents (0-4 %), which might be caused by the magnitude calculation of water-/fat-only images (noise bias) [3] affecting fat estimates according to the previously described algorithm (Eq.”
BackgroundMethodResultInfluentialAbdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se34876 · Cited by 538 · cited 1×
“Advantages over MRS include a fast and volumetric data acquisition with both visualisation of anatomical structures and quantification of MFC in an ROI [22].”
MethodRelaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394 · cited 1×
“show—similar to the ex vivo study—a measurement bias of 2pt-MRIDixon for very small and high FFDIXON, probably due to noise bias [3] and single-peak modelling of fat [28, 29] respectively, resulting in a slope of 0.”
ResultGerber, C., Schneeberger, A. G., Hoppeler, H., & Meyer, D. C. (2007) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2007.02.122 · Cited by 340 · cited 2×
“Several studies have suggested that assessment of MFC may serve as a biomarker for detection of muscular insufficiency and prediction of post-surgical outcome in degenerative musculoskeletal disease [2, 7, 9, 10, 16, 18].”
Background
Cited by
Imaging of sarcopenia: old evidence and new insights
Albano, D., Messina, C., Vitale, J., & Sconfienza, L. M. (2020) · European Radiology · doi:10.1007/s00330-019-06573-2 · Cited by 400
Sarcopenia: Current Concepts and Imaging Implications
Boutin, R. D., Yao, L., Canter, R. J., & Lenchik, L. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14635 · Cited by 323
“For example, a 2-point Dixon-based technique has been used to quantify muscle-fat content in the leg of patients with achillodynia [84].”
MethodSarcopenia: how to measure, when and why
Tagliafico, A. S., Bignotti, B., Torri, L., & Rossi, F. (2022) · La radiologia medica · doi:10.1007/s11547-022-01450-3 · Cited by 268
“[54] For these advanced MRI applications, Dixon-based MRI sequences resulted to be more reliable and easier to be handled than spectroscopy Dixon [53].”
MethodApplication of ultrasound for muscle assessment in sarcopenia: towards standardized measurements
Perkisas, S., Baudry, S., Bauer, J., Beckwée, D., De Cock, A.-M., Hobbelen, H., Jager-Wittenaar, H., Kasiukiewicz, A., Landi, F., Marco, E., et al. (2018) · European Geriatric Medicine · doi:10.1007/s41999-018-0104-9 · Cited by 255
Martin, R. L., Chimenti, R., Cuddeford, T., Houck, J., Matheson, J. W., McDonough, C. M., Paulseth, S., Wukich, D. K., & Carcia, C. R. (2018) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2018.0302 · Cited by 255
Metadata
- Authors
- Fischer, M. A., Pfirrmann, C. W. A., Espinosa, N., Raptis, D. A., & Buck, F. M.
- Affiliations
- Universitätsklinik Balgrist (CH)
- University Hospital Zurich (CH)
- Corresponding author
- Fischer, Michael. A.
- Venue
- European Radiology
- Published
- 2014-03-07
- Volume
- 24
- Issue
- 6
- Pages
- 1366-1375
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2128564886
- Cited by
- 112
- References
- 32
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 11 · 2023: 9 · 2022: 11 · 2021: 11 · 2020: 15 · 2019: 8 · 2018: 11 · 2017: 7 · 2016: 7 · 2015: 5 · 2014: 3
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- green
- www.zora.uzh.ch
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- European Radiology (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, other-oa)
- reroDoc Digital Library (submittedVersion)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Keywords
- muscle fat content, achillodynia, Achilles tendon, gastrocnemius, fat fraction quantification, MR spectroscopy
- MeSH terms
- Achilles Tendon, Adipose Tissue, Adult, Aged, Aged, 80 and over, Female, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Magnetic Resonance Spectroscopy, Muscle, Skeletal, Phantoms, Imaging, Adiposity, Tendinopathy, Healthy Volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dixon-based MRI for assessment of muscle-fat content in phantoms, healthy volunteers and patients with achillodynia: comparison to visual assessment of calf muscle quality. https://app.cochat.ai/papers/10.1007/s00330-014-3121-1
- The paper
- Fischer, M. A., Pfirrmann, C. W. A., Espinosa, N., Raptis, D. A., & Buck, F. M. (2014). Dixon-based MRI for assessment of muscle-fat content in phantoms, healthy volunteers and patients with achillodynia: comparison to visual assessment of calf muscle quality. European Radiology. https://doi.org/10.1007/s00330-014-3121-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.